58
OPTO
OPTICAL-ELECTRIC SENSOR LINEUP
Distance Measuring Sensor Lineup
Output Detected distance Features Model No.
1-bit digital output according
to distance measuring 5 cm Battery drive compatible, compact, 1-bit digital output GP2Y0D805Z0F
10 cm Battery drive compatible, compact, 1-bit digital output GP2Y0D810Z0F
15 cm Battery drive compatible, compact, 1-bit digital output GP2Y0D815Z0F
13 cm 1-bit digital output GP2Y0D413K0F
24 cm 1-bit digital output GP2Y0D21YK0F
80 cm 1-bit digital output GP2Y0D02YK0F
Analog voltage output
according to distance
measuring
(Including I
2
C output) 1.5 to 15 cm Analog output GP2Y0AF15 series
2 to 15 cm Analog output GP2Y0A51SK0F
4 to 30 cm Analog output GP2Y0A41SK0F / GP2Y0AF30 series
4 to 50 cm CMOS type Analog output GP2Y0E02A
I
2
C output GP2Y0E02B
Analog, I
2
C output GP2Y0E03
10 to 80 cm Analog output GP2Y0A21YK0F
10 to 150 cm
Compact (22 × 8 × 7.2 [T] mm),
Analog output GP2Y0A60SZLF
20 to 150 cm Analog output GP2Y0A02YK0F
100 to 550 cm Analog output GP2Y0A710K0F
Dust Sensor Unit Lineup
Output Features Model No.
Analog output
Pulse analog output, single-shot detection of house dust,
general purpose GP2Y1010AU0F
Single-shot detection of house dust, LED drive via external input,
high sensitivity GP2Y1012AU0F
Digital output
Digital (PWM) output, built-in microprocessor controller,
single-shot detection of house dust, high sensitivity GP2Y1023AU0F
Digital (UART) output, built-in microprocessor controller,
sensing can discriminate between PM2.5 and PM10, internal
cleaning possible
GP2Y1030AU0F
Under development
59
Optoelectronics
OPTO
DISTANCE MEASURING SENSORS
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Distance Measuring Sensors (1)
Digital Output
(Ta = 25°C)
Model No.
Detected
distance
(cm)
Features
Absolute maximum ratings Electro-optical characteristics
*1
Vcc
(V)
Topr
C)
V
OH
(V)
MIN.
V
OL
(V)
MAX.
Dissipation current
Operating
(mA)
Standby
(µA)
GP2Y0D805Z0F 5
Light detector,
infrared LED and signal processing circuit,
short distance measuring type,
battery drive compatible
(operating power supply: 2.7 to 6.2 V)
0.3 to +7 –10 to +60 Vcc0.6 0.6 MAX. 6.5 MAX. 8
GP2Y0D810Z0F 10
Light detector,
infrared LED and signal processing circuit,
short distance measuring type,
battery drive compatible
(operating power supply: 2.7 to 6.2 V)
0.3 to +7 –10 to +60 Vcc0.6 0.6 MAX. 6.5 MAX. 8
GP2Y0D815Z0F 15
Light detector,
infrared LED and signal processing circuit,
short distance measuring type,
battery drive compatible
(operating power supply: 2.7 to 6.2 V)
0.3 to +7 –10 to +60 Vcc0.6 0.6 MAX. 6.5 MAX. 8
GP2Y0D413K0F 13
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
digital voltage output according to the measured
distance
0.3 to +7 –10 to +60 Vcc0.3 0.6
GP2Y0D21YK0F 24
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
digital voltage output according to the measured
distance
0.3 to +7 –10 to +60 Vcc0.3 0.6 MAX. 40
GP2Y0D02YK0F 80
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
long distance measuring type
(No external control signal required),
digital voltage output according to the measured
distance
0.3 to +7 –10 to +60 Vcc0.3 0.6 MAX. 50
*1 Vcc = 5 V PSD: Position Sensitive Detector
60
OPTO
DISTANCE MEASURING SENSORS
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Distance Measuring Sensors (2)
Analog Output (Including I2C output)
(Ta = 25°C)
Model No.
Distance
measuring
range
(cm)
Features
Absolute maximum ratings Electro-optical characteristics
*1
Vcc
(V)
Topr
C)
V
OH
(V)
MIN.
V
OL
(V)
MAX.
Dissipation
current
Operating
(mA)
GP2Y0AF15 series 1.5 to 15
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms), compact,
lineup of various connector shapes
0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 15 cm),
∆V
O
(TYP.) = 2.3 V
(at L = 15 cm 1.5 cm)
T Y P. 17
GP2Y0A51SK0F 2 to 15
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms)
0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 15 cm),
∆V
O
(TYP.) = 2.25 V
(at L = 15 cm 2 cm)
T Y P. 12
GP2Y0AF30 series 4 to 30
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms), compact,
lineup of various connector shapes
0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 30 cm),
∆V
O
(TYP.) = 2.3 V
(at L = 30 cm 4 cm)
T Y P. 17
GP2Y0A41SK0F 4 to 30
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms)
0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 30 cm),
∆V
O
(TYP.) = 2.25 V
(at L = 30 cm 4 cm)
MAX. 22
GP2Y0E02A 4 to 50
Infrared LED and CMOS image sensor with built-in
signal processing circuit, compact size
(18.9 × 8 × 5.2 mm), high-precision measurement,
analog output
0.3 to +3.6 –10 to +60
V
OUT
(A) 1 = 0.3 to 0.8 V
(at L = 50 cm),
V
OUT
(A) 3 = 2.1 to 2.3 V
(at L = 4 cm)
MAX. 36
GP2Y0E02B 4 to 50
Infrared LED and CMOS image sensor with built-in
signal processing circuit, compact size
(18.9 × 8 × 5.2 mm), high-precision measurement,
I
2
C output
0.3 to +3.6 –10 to +60
D1 = 45 to 50 cm
(at L = 50 cm),
D3 = 3 to 5 cm
(at L = 4 cm)
MAX. 36
GP2Y0E03 4 to 50
Infrared LED and CMOS image sensor with built-in
signal processing circuit, compact size
(16.7 × 11 × 5.2 mm), high-precision measurement,
analog / I
2
C output both compatible
0.3 to +5.5 10 to +60
V
OUT
(A) 1 = 0.3 to 0.8 V,
D1 = 45 to 50 cm
(at L = 50 cm),
V
OUT
(A) 3 = 2.1 to 2.3 V,
D3 = 3 to 5 cm
(at L = 4 cm)
MAX. 36
GP2Y0A21YK0F 10 to 80
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
linear voltage output
0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 80 cm),
∆V
O
(TYP.) = 1.9 V
(at L: 80 cm 10 cm)
MAX. 40
GP2Y0A60SZLF 10 to 150
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
compact type (22 x 8 x 7.2 mm),
long distance measuring type
(No external control signal required)
0.3 to +5.5 10 to +60
V
O
(TYP.) = 0.65 V
*2
(at L = 150 cm),
∆V
O
(TYP.) = 3.0 V
(at L = 150 cm 20 cm)
MAX. 50
GP2Y0A02YK0F 20 to 150
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
long distance measuring type
(No external control signal required)
0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 150 cm),
∆V
O
(TYP.) = 2.05 V
(at L = 150 cm 20 cm)
MAX. 50
GP2Y0A710K0F 100 to 550
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
long distance measuring type
(No external control signal required)
0.3 to +7 –10 to +60
V
O
(TYP.) = 2.5 V
(at L = 100 cm),
∆V
O
(TYP.) = 0.7 V
(at L = 100 cm 200 cm)
T Y P. 3 0
*1 Vcc = 5 V PSD: Position Sensitive Detector
*2 When Vcc = 3 V: Vo (TYP.) = 0.35 V (at L = 150 cm); ∆Vo (TYP.) = 1.6 V (at L = 150 cm 20 cm)
New product
61
Optoelectronics
OPTO
DISTANCE MEASURING SENSORS /
DUST SENSOR UNIT
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
GP2Y0D805Z0F

⎜
⎜
GP2Y0D810Z0F,
GP2Y0D815Z0F,
GP2Y0D810Z1F
⎜
⎜
GP2Y0E02A
(GP2Y0E02B)
GP2Y0E03 GP2Y0A60SZLF GP2Y0AF15 series
GP2Y0AF30 series GP2Y0A21YK0F
⎜
⎜
⎜
⎜
GP2Y0D21YK0F,
GP2Y0A41SK0F
GP2Y0D413K0F:
without mounting
hole
⎜
⎜
⎜
⎜
GP2Y0A51SK0F GP2Y0D02YK0F
(GP2Y0A02YK0F)
GP2Y0A710K0F
Dust Sensor Unit
(Ta = 25°C)
Model No. Features Topr
C)
Operating
supply voltage
(V)
Electro-optical characteristics
Dissipation
current
(mA)
Detection
concentration
μg/m
3
( T YP.)
Output
 
GP2Y1010AU0F
Built-in infrared emitting diode,
photodiode and signal processing circuit
Compact, single-shot detection of house dust
Output: Analog voltage
–10 to +65
4.5 to 5.5 T Y P. 11 0 to 600 Analog voltage
 
GP2Y1012AU0F
High sensitivity
Built-in infrared emitting diode,
photodiode and signal processing circuit
Compact, single-shot detection of house dust
Output: Analog voltage
4.5 to 5.5 T Y P. 11 0 to 240 Analog voltage
 
GP2Y1023AU0F
High sensitivity
Built-in microcomputer
Built-in infrared emitting diode,
photodiode and signal processing circuit
Compact, single-shot detection of house dust
Output: Digital signal output (PWM)
4.75 to 5.25 T Y P. 15 0 to 240
Digital signal (PWM)
Temperature correction
Averaging
GP2Y1030AU0F
Built-in infrared emitting diode,
photodiode and signal processing circuit
Built-in microcomputer
Sensing can discriminate between PM2.5 and
PM10
Internal cleaning possible
3 to 5.5 TYP. 25 0 to 500 Digital signal (UART)
GP2Y1010AU0F
(GP2Y1012AU0F, GP2Y1023AU0F)
GP2Y1030AU0F
Under development