60
OPTO
DISTANCE MEASURING SENSORS
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
■Distance Measuring Sensors (2)
♦
Analog Output (Including I2C output)
(Ta = 25°C)
Model No.
Distance
measuring
range
(cm)
Features
Absolute maximum ratings Electro-optical characteristics
*1
Vcc
(V)
Topr
(°C)
V
OH
(V)
MIN.
V
OL
(V)
MAX.
Dissipation
current
Operating
(mA)
☆
GP2Y0AF15 series 1.5 to 15
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms), compact,
lineup of various connector shapes
–0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 15 cm),
∆V
O
(TYP.) = 2.3 V
(at L = 15 cm → 1.5 cm)
T Y P. 17
GP2Y0A51SK0F 2 to 15
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms)
–0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 15 cm),
∆V
O
(TYP.) = 2.25 V
(at L = 15 cm → 2 cm)
T Y P. 12
☆
GP2Y0AF30 series 4 to 30
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms), compact,
lineup of various connector shapes
–0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 30 cm),
∆V
O
(TYP.) = 2.3 V
(at L = 30 cm → 4 cm)
T Y P. 17
GP2Y0A41SK0F 4 to 30
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
short measuring cycle (16.5 ms)
–0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 30 cm),
∆V
O
(TYP.) = 2.25 V
(at L = 30 cm → 4 cm)
MAX. 22
GP2Y0E02A 4 to 50
Infrared LED and CMOS image sensor with built-in
signal processing circuit, compact size
(18.9 × 8 × 5.2 mm), high-precision measurement,
analog output
–0.3 to +3.6 –10 to +60
V
OUT
(A) 1 = 0.3 to 0.8 V
(at L = 50 cm),
V
OUT
(A) 3 = 2.1 to 2.3 V
(at L = 4 cm)
MAX. 36
GP2Y0E02B 4 to 50
Infrared LED and CMOS image sensor with built-in
signal processing circuit, compact size
(18.9 × 8 × 5.2 mm), high-precision measurement,
I
2
C output
–0.3 to +3.6 –10 to +60
D1 = 45 to 50 cm
(at L = 50 cm),
D3 = 3 to 5 cm
(at L = 4 cm)
MAX. 36
GP2Y0E03 4 to 50
Infrared LED and CMOS image sensor with built-in
signal processing circuit, compact size
(16.7 × 11 × 5.2 mm), high-precision measurement,
analog / I
2
C output both compatible
–0.3 to +5.5 –10 to +60
V
OUT
(A) 1 = 0.3 to 0.8 V,
D1 = 45 to 50 cm
(at L = 50 cm),
V
OUT
(A) 3 = 2.1 to 2.3 V,
D3 = 3 to 5 cm
(at L = 4 cm)
MAX. 36
GP2Y0A21YK0F 10 to 80
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
linear voltage output
–0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 80 cm),
∆V
O
(TYP.) = 1.9 V
(at L: 80 cm → 10 cm)
MAX. 40
GP2Y0A60SZLF 10 to 150
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
compact type (22 x 8 x 7.2 mm),
long distance measuring type
(No external control signal required)
–0.3 to +5.5 –10 to +60
V
O
(TYP.) = 0.65 V
*2
(at L = 150 cm),
∆V
O
(TYP.) = 3.0 V
(at L = 150 cm → 20 cm)
MAX. 50
GP2Y0A02YK0F 20 to 150
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
long distance measuring type
(No external control signal required)
–0.3 to +7 –10 to +60
V
O
(TYP.) = 0.4 V
(at L = 150 cm),
∆V
O
(TYP.) = 2.05 V
(at L = 150 cm → 20 cm)
MAX. 50
GP2Y0A710K0F 100 to 550
Distance measuring sensor united with PSD
※
,
infrared LED and signal processing circuit,
long distance measuring type
(No external control signal required)
–0.3 to +7 –10 to +60
V
O
(TYP.) = 2.5 V
(at L = 100 cm),
∆V
O
(TYP.) = 0.7 V
(at L = 100 cm → 200 cm)
T Y P. 3 0
*1 Vcc = 5 V ※ PSD: Position Sensitive Detector
*2 When Vcc = 3 V: Vo (TYP.) = 0.35 V (at L = 150 cm); ∆Vo (TYP.) = 1.6 V (at L = 150 cm → 20 cm)
☆New product