8–3
TR
Note:
Excitation voltage ripple should be maintained below 5% by use of appropriate smoothing.
Strong external magnetic fields influence relay data.
1) Data concerning operational life is based on resistive loads and ambient temperature of 20-30°C.
TR-W Wiping function on request With surge voltages
(1.2/50µsec) over DC 500V
TR-i. b. w relays may not
operate as intended.
Characteristics Remarks
Type of contacts (CO = changeover)
Max. make/rated/break current A
Voltage switching range VDC (VAC)
Power switching range W (VA)
Contact material
Volumetric/contact resistance (at 5 V, 10 mA)mΩΩ
Operat. life1) mech. with contact loading switching ops.
0.5A, 10W / 1A, 1W switching ops.
0.2A, 12V / 1mA, 1mV switching ops.
Voltage withstand: cont./cont.-control circuitry Veff
Insulation resistance: cont./cont.-control circuitry Ω
Shock and vibration resistance g-g/Hz
Life of trimmer
Type of protection
Storage temperature °C
Permiss. ambient temp. at max. load °C
Min. control pulse duration at rated voltage. ms
1 CO
3 / 1 / 1
10-5-110 (240)
10-4-20 (30)
AuCo
50/30
109
107/108
108/109
500/750
109/1010
50-20/2000
>100 operations
dust tight/IP50
-20/+85
-20/+65
100
240 V using only
1 circuit
See also the
R relay data sheet
Independant of position
typically 1000 ops.
Consequently , time tol: < 4% with
-i- devices 30 % with -0- devices
Operating characteristics
Type: – i – ”on“ delay
– b – pulse relay
TR – i – 5 V/TR – b – 5 V
TR – i – 12 V/TR – b – 12 V
TR – i – 24 V/TR – b – 24 V
Rated time: „on“ delay „i“ 0 s +) 10 s 100s 800s
Minimum timing range [s]
at rated voltage 1-1000 0.1-10 1-100 8-800
Time tolerance at Urated ± 20% < 2%
Pulse relay „b“ pulse frequency 0.04 … 5 Hz*
Operating
voltage
V
4.0 – 9.0
8.5 – 18.0
17.0 – 30.0
Current
Consumpt.
mA
30
15
14
Type: – o – ”off“ delay
TR – o – 5 V
TR – o – 12 V
TR –o – 24 V
Rated time: „off“ delay „o“ 0 s +) 10 s 100s
Minimum timing range [s]
at rated voltage 0.3-100 0.1-10 1-100
Time tolerance at Urated ± 20% – approx 5%
Time delay increase with Cext per µF – 1.5s 4.7s
Operating
voltage
V
4.5 – 9.0
8.5 – 18.0
18.0 – 28.0
Current
Consumpt.
mA
65
35
25
Connection diagram (bottom view) Warning! No revers battery protection
Ordering example
Approximately 8 g
Housing material: CRASTIN SK-615 FR
Basic grid 2.54 mm
PCB hole dia. 1.0 mm ± 0.1 mm
Housing tolerance ± 0.3 mm
Operation
+ The trimmer is omitted on the -i/-o- 0s device.
This must be replaced by an external potentiometer. The time
delay thus achievable is 20s per 100 kΩΩwith the -i- devices
and approx 20s per 1 MΩΩwith the -o- devices.
The minimum time delays are 1s (with -i-) and 0.1 s (with -o-).
* With the -o- 0s device, the pulse frequency is 5 Hz. max.,
and is inversely proportional to Rext(e.g. at 20 kΩΩthe pulse
frequency is 1 Hz).
TR –i–5, 12, 24 V – 0s
TR –b–5, 12, 24 V – 0s TR –o–5, 12, 24 V – 10s or 100s
TR – i –5, 12, 24 V – 10s, 100s or 800s
TR –b–5, 12, 24 V – 25s
TR –o–5, 12, 24 V – 0s