AMSC N/A FSC 5935
MIL-PRF-39012/1J
w/AMENDMENT 1
21 November 2016
SUPERSEDING
MIL-PRF-39012/1J
26 February 2016
PERFORMANCE SPECIFICATION SHEET
CONNECTORS, PLUG, ELECTRICAL, COAXIAL, RADIO FREQUENC Y,
(SERIES N (CABLED), PIN CONTACT, CLASS 2)
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of
this specification sheet and MIL-PRF-39012.
NOTES:
1. Dim ensions are in inches. Metric equivalents are given for information only.
2. For dimensions A and B, see tables I and III.
3. Dimensions A and B are the largest overall dimensions of the connector.
4. Wrench flats are to accommodate standard wrench opening in accordance wit h F ED-STD-H28.
5. All undimensioned pictorial representations are for reference purposes only.
6. Dimension A defines the maximum length of the connector when assembled to the appropriate
cable.
7. Three holes .027 inch (0.69 mm) minimum diameter, equally spaced, are required for safety
wiring after mating. Location on the coupling nut is optional.
8. Series N, pin contact interface, in accordance with MIL-STD-348.
FIGURE 1. General configuration.
INCH-POUND
MIL-PRF-39012/1J
w/AMENDMENT 1
2
Inches mm
.007 0.18
.010 0.25
.032 0.81
.103 2.62
.524 13.31
NOTES:
1. Dimensions are in inches. Metric equivalents are given for information only.
2. Three holes .027 inch (0.69 mm) minimum diameter, equally spaced, are required for safety wiring
after mating. Location on the coupling nut is optional.
3. Chamfer is optional, if chamfer is used put chamfer on a 30° maximum.
4. Dimension shall meet connector performance requirements.
FIGURE 2. Category D captivation detail.
MIL-PRF-39012/1J
w/AMENDMENT 1
3
TABLE I. Dash numbers, cross-reference, and dimensions.
Part or Identifying
Number (PI N)
M39012/01- 1/
Applicable cabl e
M17/
2/
Dimensions
Inches
(millimeters)
maximum #
Category A Field serviceable (no special tools required) 3/ 4/
X101
Cable group VIII
112-RG304 5/
A
B
1.875 (47.63)
.827 (21.01)
X104
Cable group XIV
79-RG218 5/
A
B
2.500 (63.50)
1.343(34.11)
X005
Cable group X
86-00001 6/
127-RG393 5/
A
B
1.875 (47.63)
.827 (21.01)
X015
Cable group XII
78-RG217 5/
A
B
1.875 (47.63)
.906 (23.07)
X125
Cable group XI
74-RG215 5/ 7/
189-00002 7/
A
B
2.500 (63.50)
.827 (21.01)
X030
220-00001
A
2.500 (63.50)
X130
220-00002 7/
X031
221-00001
X131
221-00002 7/
X032
222-00001
X132
222-00002 7/
X033
223-00001
X133
223-00002 7/
X034
224-00001
X134
224-00002 7/
X035
225-00001
X135
225-00002 7/
X036
226-00001
X136
226-00002 7/
X037
227-00001
X137
227-00002 7/
X038
228-00001
X138
228-00002 7/
See notes at end of table.
MIL-PRF-39012/1J
w/AMENDMENT 1
4
TABLE I. Dash numbers, cross-reference, and dimensionsContinued.
PIN
M39012/01- 1/
M17/
2/
Dimensions
Inches
(millimeters)
maximum #
Categor y C Field replaceable (MIL-DTL-22520 crimp tool)
See note next to applicable cable group for crimp die 3/ 4/ 8/
X016
Cable group VIII 9/
112-RG304 5/
A
B
2.000 (63.50)
.827 (21.01)
X017
Cable group XA 10/
65-RG165 5/ 6/
X018
Cable group XB 10/
75-RG214
X023
Cable group XC 10/
62-RG144 4/ 5/ 6/
X024
Cable group XD 10/
77-RG216 4/ 5/ 6/
See notes at end of table.
MIL-PRF-39012/1J
w/AMENDMENT 1
5
TABLE I. Dash numbers, cross-reference, and dimensionsContinued.
PIN
M39012/01- 1/
Applicable cabl e
M17/
2/
Dimensions
Inches
(millimeters)
maximum #
Category D Field replaceable – Defined piece part 3/ 4/ 8/ 11/
X501
Cable group XB
127-RG393 5/
A
B
1.593 (40.48)
.827 (21.01)
X502
Cable group XA
65-RG165 5/
X503
Cable group VIB
60-RG142 6/
128-RG400 5/
A
B
1.516 (38.50)
.827 (21.01)
X504
Cable group VIA
111-RG303 5/
1/ For cross-reference of dash number to superseded Part or Identifying Part Number (PIN) or type designation,
see table IV.
2/ The latest version of each cable shall be applied.
3/ These connectors have captivate d center co nt ac ts.
4/ Some of the cables in some cable groups are not 50 ohms; therefore, when attached to the specified
connectors, VSWR, RF leakage and i nsertion loss are not applicable. Refer to MIL-PRF-39012
appendix for cable groupings.
5/ Cable to be used when performing tests requiring cable except as in 4/ and 6/.
6/ Cable to be used for the +200°C temperature cycling tests.
7/ Armored cable.
8/ These connectors are assembled using the applicable crimp tool, to the specified cables stripped as
shown on figure 4.
9/ M22520/5-35 closure A or M22520/5-55 clo sure A.
10/ M22520/5-61.
11/ Compl ete con ne ctor ass e mbly shal l consist of a body, cent er cont act , ferru le and as se mbly
instructions.
# Dimensions are in inches. Metric equivalents are given for information only.
X Denotes connector body plating material option. The only plating options allowable are Silver or Nickel over
brass in accord anc e w ith MIL-PRF-39012. Only connectors of the same materials shall be mated to avoid
dissimilar metal pr ob lem s. CAUTION: A NICKEL PLATED BODY I S NOT FOR USE IN
APPLICATIONS WHERE PASSIVE INTERMODULATION GENERATION (PIM) MAY BE A
CONCERN. Silver is the preferred plating option.
MIL-PRF-39012/1J
w/AMENDMENT 1
6
Inches
mm
Inches
mm
.001
0.03
.210
5.33
.002
0.05
.220
5.59
.003
0.08
.230
5.84
.005
0.13
.234
5.94
.008
0.20
.245
6.22
.015
0.38
.250
6.35
.031
0.79
.292
7.42
.036
0.91
.303
7.70
.043
1.09
.418
10.62
.098
2.49
.438
11.13
.104
2.64
.492
12.50
.120
3.05
.500
12.70
.156
3.96
.600
15.24
.206
5.23
.800
20.32
Dash
number
Contact
number
1/ A B
Basic
crimp
tool
2/
Crimp die
or
positioner
Crimp
tensile
minimum,
pounds
(N)
Color
band
Color
band
ο
X501
X502
1-10
.098
± .002
.008 ±
.002
x
30° ± 5°
M22520/1-
01
M22520/1-
13
60 lbs.
(266.90)
Red
Black
X503
X504 1-11
.043
+ .001
- .002
M22520/5-
01
M22520/5-
25
Closure B
20 lbs
(88.96)
Blue
1/ Contact numbers are for identification only.
2/ Class 2 tool may be used by OEM (see MIL-DTL-22520).
FIGURE 3. Contact and ferrule dimensions for category D only.
MIL-PRF-39012/1J
w/AMENDMENT 1
7
1/ Ferrule numbers are for identification only.
2/ Class 2 tools may be used by OEM (see MIL-DTL-22520).
NOTES:
1. Dim ensions are in inches. Metric equivalents are given for information only.
2. Crimp tensile test shall be in accordance with SAE-AS39029.
3. Copyright notice: All information disclosed in these specification sheets which is or may be
copyrighted is reproduced herein with the express permission of the copy right owner.
4. Maximum break .003 inch (0.08 mm).
5. Color bands shall be positioned so that no coloring material enters the inspection hole.
FIGURE 3. Contact and ferrule dimensions for category D onlyContinued.
Dash no. Ferrule no.
1/
A
B
C
Basic crimp
tool 2/
M22520/5
Crimp die or
positioner
M22520/5-
X501
1-50
.492 ± .003
.438 ± .003
.600 ± .015
-01
61 or 25
Closure A
X502
1-51
.418 ± .003
X503
1-52
.250 ± .003
.220 ± .003
.500 ± .015
05, 11, 57
Closure A or
19 Closure B
X504
1-53
.245 ± .003
.206 ± .003
MIL-PRF-39012/1J
w/AMENDMENT 1
8
Inches mm
.177 4.50
.197 5.00
.396 10.06
.416 10.57
.490 12.45
.510 12.95
.687 17.45
NOTES:
1. Dimens ions are in inches . Metric equivalents are given for information only.
FIGURE 4. Cable stripping dimensions for field replaceable connectors.
ENGINEERING DATA:
Nom inal im pedanc e: 50 ohm s .
Frequency range: 0 to 11 GHz.
Voltage rating:
1,000 volts rms maximum working voltage at sea level.
250 volts rms maximum at 70,000 feet (4.437 kPa).
Temperature rating: -65°C to +165°C.
REQUIREMENTS:
Design and configuration: See figures 1, 2, 3, and 4.
Force to engage and disengage:
Longitudinal force: Not applicable.
Torque: 6 inch-pounds (.68 Nm) maximum.
MIL-PRF-39012/1J
w/AMENDMENT 1
9
Coupling pr oof torqu e: 15 inch-pounds (1.69 Nm) minimum.
Inspection conditions: Coupling torque: 6 to 10 inch-pounds (.68 to 1.13 Nm).
Mating characteristics: In accor danc e with MIL-STD-348 and figure 2.
Outer contact:
Test ring ID: .316 inch (8.03 mm) maximum, 16 microinch (0.406 µm) finish.
Insertion force: 25 pounds (111.20 N) maximum when inserted a minimum of .093 inch (2.36 mm).
Contacts with slotted members: Shall contact a .324 inch (8.23 mm) minimum diameter ring within
.031 inch (0.79 mm) of their tip ends.
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: MIL-STD-202-302, test condition B. 5,000 megohms minimum.
Center contact retention: (Applicable to captivated-center-contact connectors only.) 15 pounds
(66.72 N) minimum axial force for all cables except RG400 and RG142; 6 pounds (26.69 N) minimum for
RG400 and RG142.
Corrosion (salt spray): MIL-STD-202-101, test condition B.
Voltage standing wave ratio (VS WR): From .5 to 11 GHz, or approximately 80 percent of upper cutoff
frequency of the cable, whichever is lower; 1.30 maximum (1.45 maximum at 11 GHz for X 503 and
X504).
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.008 + .002 F (F in GHz).
Item 16: VSWR shall be less than 1.008 + .002 F (F in GHz).
Second step of VSWR checkout procedure: VSWR shall be less than 1.012 + .004 F (F in GHz).
Group B inspection: VSWR shall be less than 1.024 + .007 F (F in GHz).
Qualification and group C inspection VSWR shall not exceed 1.08.
Connector durability: 500 cycles minimum at 12 cycles/minute maximum. The connector shall meet the
mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms maximum.
Initial After environment
Center contact 1.0 1.5
Outer contact (silver) .2 Not appl ic abl e
Outer contact (nickel) .4 Not ap pl icabl e
Braid to body .05 N ot ap pl icabl e
MIL-PRF-39012/1J
w/AMENDMENT 1
10
Dielectric withs ta ndi ng volt age: MIL-STD-202-301. 2,500 volts rms minimum at sea level for connectors
using other then RG400 and RG142; 1,500 volts rms minimum for connectors using RG400 and RG142.
Vibration, high frequency: MIL-STD-202-204, test condition B.
Shock: MIL-STD-202-213, test condition I.
Thermal shock: MIL-STD-202-107, test condition B, except test high temperature shall be +85°C. High
temperature shall be +200°C for connectors using +200°C cables (see table I and III).
Moisture resistance: of MIL-STD-202-106. No measurements at high humidity. Insulation resistance
shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona level:
Voltage: 500 volts rms mini mum.
Altitude: 70,000 feet (4.437 kPa).
RF high potential withstanding voltage:
Voltage and frequency: 1,500 volts rms tested at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
Cable retention force:
Non-crimp assemblies: 75 pounds (333.62 N) minimum.
Crimp assemblies:
50 lbs minimum for cables .155 - .189 inch (3.94 mm 4.80 mm) OD.
60 lbs minimum for cables .190 - .229 inch (4.83 mm 5.82 mm) OD.
75 lbs minimum for cables .230 - .249 inch (5.84 mm 6.32 mm) OD.
90 lbs minimum for cables .250 inch (6.35 mm) OD and larger.
Coupling mechanism retention force: 100 pounds (444.82 N) minimum.
RF leakage: -90 dB minimum, tested at a frequency between 2 and 3 GHz.
Insertion loss: .15 dB maximum at 9 GHz.
PIN: M39012/01- (dash number in table I or “B” number in table III).
Group qualification. See table II.
MIL-PRF-39012/1J
w/AMENDMENT 1
11
TABLE II. Group qualification. 1/
Group
Submission and qualification of
any of the following connectors 2/
M39012/01
Qualifies the following
connectors
M39012/01
I
-X101
-X104
-X125
-X101
-X104
-X125
II
-X005
-X015
-X005
-X015
III
B0006
B0007
B0008
B0011
B0012
B0006
B0007
B0008
B0011
B0012
IV
-X016
-X017
-X018
B0006
B0007
B0008
B0011
B0012
B0013
B0014
-X016
-X017
-X018
-X023
-X024
V
B0013
B0014
B0013
B0014
VI
-X023
-X024
B0013
B0014
-X023
-X024
VII
B0026
B0026
VIII
-X501
-X502
-X501
-X502
-X503
IX
-X503
-X503
X
-X504
-X504
See notes at end of table.
MIL-PRF-39012/1J
w/AMENDMENT 1
12
TABLE II. Group qualificationContinued. 1/
1/ If a connector manufacturer produces a connector which meets all the requirements for two or more
connector PIN’s (within the same series), the manufacturer may receive qualification approval for two
or more connector PIN’s by qualifying the one connector. It is not necessary that such connectors be
in the same group. Each connector, however, must be marked with its own appropriate PIN. For
group qualification, the connectors must be of similar design and be of the same materials and
plating.
2/ For qualification retention, where more than one part is listed in a group in this column, data may be
supplied on any of those parts in order to retain qualification for those parts in the corresponding
right-hand column. The part does not necessarily have to be the part initially qualified.
TABLE III. CATEGORY B NONFIELD REPLACEABLE (SPECIAL TOOLS MAY BE REQUIRED). 1/
PIN 2/
M39012/01B
Applicable cable 3/
M17/
Dimensions
Inches (millimeters)
Maximum 9/
0006 4/
73-RG212 5/
162-00001
A
B
2.000(50.80)
.827 (21.01)
0007 4/
74-RG213 5/
0008 4/
75-RG214 5/
0011 4/
65-RG165 5/ 6/
0012 4/
86-00001
0013 4/
6-RG11 7/
62-RG144 5/ 6/ 7/
0014 4/
77-RG216 5/ 7/
0026 8/
2-RG6 6/ 7/
1/ For maintenance replacements for category B, see table V.
2/ For cross-reference of dash number to superseded PIN or type designation, see table IV.
3/ The latest version of each cable shall be applicable.
4/ Inactive for new de sign.
5/ Cable to be used when performing tests requiring cable except as in 6/ and 7/
6/ Cable to be used for the +200°C temperature cycling tests.
7/ These are not 50-ohm cables; therefore, when attached to the specified connectors, VSWR, RF
leakage, and insertion loss are not applicable.
8/ These connectors have captivated center contacts.
9/ Dimensions are in inches. Metric equivalents are given for information only.
NOT FOR ARMY, NAVY OR AIR FORCE USE. FOR OEM USE ONLY
MIL-PRF-39012/1J
w/AMENDMENT 1
13
TABLE IV. Super ses s ion d ata. 1/ 2/
Preferred PIN
M39012/01
(except as otherwise specified in
tables I or III)
Superseded PIN’s
or superseded type designation
-0005
MS91236-21G , UG -21/U, M390 12/ 01-0002,
MS90534-1185A, UG-1185A/U
-0015
MS91238-204D, UG-204/U, M39012/01-0003;
UG-1487A/U
-0016
M39012/01-0020, M39012/40-0009, M39012/40-
0032, M39012/01-0027
-0017
M39012/01-0021
-0018
M39012/01-0022
-0023
----------
-0024
----------
-0101
MS91231-18E, UG-1 8/U, M390 12/01-0001
-0104
MS91239-167F, UG-167/U, M39012/01-0004
-0125
M39012/40-0007, M3901 2/ 40-0030,
MS90293-941C, UG-9 41, M390 12/ 01-0025
B0006
M39012/01-0010, UG-1680, UG-1684,
M23329/2-01, M39012/01-0006, M23329/2-06
B0007
M23329/2-02, UG-1681, M39012/01-0007
B0008
M23329/2-03, UG-1682, M39012/01-0008
B0011
M23329/2-07, UG-1685, M39012/01-0011
B0012
M23329/2-08, UG -1695, M39012/01-0012
B0013
M23329/2-09, UG-1817, M39012/01-0013
B0014
UG-1817/U, M39012/01-0014
B0026
M39012/40-0008, M3901 2/ 40-0031,
M39012/01-0026
-0501
M39012/40-0012, M3901 2/ 40-0033
-0502
M39012/40-0013, M3901 2/ 40-0034
-0503
M39012/40-0035
-0504
UG-536/U
1/ The listed superseded PIN or type designations are for information and cross-reference only. Where a
superseded PIN or type designat ion is not giv en, no ne was ass igne d or will be
assigned. The PIN M39012/01-XXXX shall be used in all cases for marking and identifying the
connector.
2/ The basic type designation includes all letter versions of the specified number, e.g., UG-18/U includes
UG-18A/U, UG-18 B/U, etc.
MIL-PRF-39012/1J
w/AMENDMENT 1
14
TABLE V. Maintenance replacements for category B.
Categor y B
number 1/
Categor y C
dash number
Categor y A
dash number
Categor y D
dash number
B0006
B0007
B0008
B0011
B0012
B0013
B0014
B0026
0016
0017
0018
--
--
0023
0024
--
0101
0005
0005
0005
0005
0005
0005
0101
--
0502
0501
--
0501
--
--
--
1/ Category B connectors are for original installation only. They will not be stocked or procured by the
Government.
Amendment notations. The margins of this specification are marked with vertical lines to indicate
modifications generated by th i s amendment. This was done as a convenience only and the
Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and
contractors are cautioned to evaluate the requirements of this document based on the entire content
irrespective of the marginal notations.
Referenced documents. In addition to MIL-PRF-39012, this document references the following:
MIL-STD-202-101
MIL-STD-202-106
MIL-STD-202-107
MIL-STD-202-204
MIL-STD-202-213
MIL-STD-202-302
MIL-STD-348
FED-STD-H28
MIL-DTL-22520
SAE-AS39029
MIL-STD-202-301
CONCLUDING MATERIAL
Custodians: Preparing activity:
Army CR DLA CC
Navy EC
Air Force 85 (Project 5935-2017-004)
NASA NA
DLA - CC
Review acti vities:
Army AR, AT, EA, MI
Navy AS, MC, OS, SH
Air Force 19, 99
NOTE: The activities listed above were interested in this document as of the date of this document.
Since organizations and responsibilities can change, you should verify the curren cy of the information
above using the ASSIST Online database at https://assist.dla.mil.