QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 968A-A
ISOLATED DC/DC POWER CONVERTER
1
LT1952
DESCRIPTION
Demonstration circuit 968A-A is isolated input to
high current output 1/8th Brick footprint con-
verter featuring the LT®1952 switching control-
ler. The DC968 converts isolated 36V to 75V
input to 3.3V output and provides over 30A of
output current. The converter operates at
300kHz with efficiency greater than 91%. The
DC968 can be easily modified to generate out-
put voltages in the range from 0.6V to 28V. The
output currents are limited by total output power
of up to 200W. The other available versions of
DC968A are:
DC968A-B 18-36Vin to 5V@20A
DC968A-C 36-75Vin to 12V@12A
DC968A-D 36-75Vin to 28V@4A
Also, the DC968 can be modified for other input
voltages like 8V-36V, 18V-75V, 44V-52V, and so
on. The wider input voltage range will decrease
the converter efficiency. Therefore, narrow input
voltage range will be more desirable.
The DC968 circuit features soft-start which pre-
vents output voltage overshoot on startup or
when recovering from overload condition.
The DC968 has precise over-current protection
circuit that allows for continuous operation un-
der short circuit conditions. The low power dis-
sipation under short circuit conditions insures
high reliability even during short circuits.
The LT1952 can be synchronized to an external
clock of up to 400kHz. Please refer to LT1952
data sheet for design details and applications
information.
Design files for this circuit board are avail-
able. Call the LTC factory.
LT is a trademark of Linear Technology Corporation
Table 1.
Performance Summary
PARAMETER CONDITION VALUE
Minimum Input Voltage IOUT = 0A to 30A 36V
Maximum Input Voltage IOUT = 0A to 30A 75V
VOUT VIN = 36V to 75V, IOUT = 0A to 30A 3.3V ±3%
Typical Output Ripple VOUT VIN = 36V to 75V, IOUT = 0A to 30A 50mVP–P
Nominal Switching Frequency 300kHz
QUICK START PROCEDURE
Demonstration circuit 968 is easy to set up to
evaluate the performance of LT1952 circuit. Re-
fer to Figure 1 for proper measurement
equipment setup and follow the procedure be-
low:
NOTE:
When measuring the input or output
voltage ripple, care must be taken to avoid a
long ground lead on the oscilloscope probe.
Measure the input or output voltage ripple by
touching the probe tip directly across the Vin or
Vout and GND terminals. See Figure 2. for