38
SSG Series 5W/10W/15W/30W/50W/100W/150W
Rating
Item Conditions
Rated Input Voltage
Input Voltage Range
Input Current (see Note 1)
Rated Frequency
Frequency Range
Efficiency (typ) (see Note 1)
Inrush Current (see Note 1, 2)
Rated Output Voltage
Adjustable Output Voltage Range
Rated Output Current
Adjustable Output Current Range
Maximum Output Power
Ripple (mVp-p) (see Note 1, 4)
Static Input Range 85 to 132V AC
Static Load Range 0 to 100%
Time Driftt 10min. to 8 hours
Ambient Temperature Range 0 to +50°C
Output Holdup Time (see Note 1)
Startup Time (see Note 1)
Leakage Current (see Note 1)
Over Current Protection
Over Voltage Protection
Remote On/Off Control
Remote Sensing
Temperature Operating Temperature
Storage Temperature
Relative Humidity Operating Humidity
Storage Humidity
Insulation Withstand Voltage Between Input and Output
Between Input and Frame
Between Output and Frame
Insulation Resistance Between Input and Output
Between Input and Frame
Between Output and Frame
Safety Standards
EMI Standards
External Appearance
Size (dimensions in mm)
Weight (without cover)
Input
Note 1: Rated input/output conditions means that the switching power supply is operated under the rated input voltage, rated frequency, rated output voltage, and at an ambient
temperature of 25°C and 60% humidity.
Note 2: At cold start. (More current may flow at restart.)
Note 3: All output characteristics are measured at a point 5 cm from the output connector, with a 63 V 47 µF electrolytic capacitor attached at that point.
Note 4: Ripple noise is measured with a 100 MHz oscilloscope, using a 1:1 probe.
Output (see Note 3)
Other
Additional
Functions
EnvironmentalInsulation
Structural
Specifications
Applicable
Standards
Constant Voltage
Accuracy
15W
SSG 015-05 SSG 015-12 SSG 015-15 SSG 015-24
100-120V AC
85 to 132V AC
0.5A (typ)
50/60 Hz
47 to 440 Hz
72% 75% 75% 78%
30 A (max)
+5V +12V +15V +24V
Rated voltage ±10%
3.0A 1.3A 1.0A 0.7A
0 to 100%
15W 15.6W 15W 16.8W
120mVp-p 170mVp-p 200mVp-p 300mVp-p
±3%
10ms (min)
40ms (typ)
0.5mA (max)
Detection above 120% of rated current (output cutoff)
Detection above 120% of rated voltage (output cutoff)
Not provided
Not provided
0 to 50°C (no cover)
-25 to +85°C
30 to 90% (no condensation)
30 to 90% (no condensation)
2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less)
500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less)
100 MΩ(measured with 500 V DC Megger)
UL and CSA certified
Conforms to FCC Class B
PCB type,
input and output connectors (chassis and input/output terminal stand are optional)
70 x 92 x 20 (W x D x H)(with chassis)
100 g (150 g with chassis)