DC-DC
Specification
50-200 Watts
•2:1 & 4:1 Input Ranges
•Efficiency up to 90%
•Single Output
•-40 °C to +100 °C Operating Temperature
•Continuous Short Circuit Protection
•Five-sided Metal Case
•3 Year Warranty
ICH/IFH Series
Input
Input Voltage Range • See tables
Input Current (no load) • See tables
Input Reverse Voltage • None
Protection
Input Filter • Pi network
Undervoltage Lockout • 2:1 Input Models:
12 Vin, power up 8.8 V, down 8.0 V
24 Vin, power up 17.0 V, down 16.0 V
48 Vin, power up 34.0 V, down 32.5 V
4:1 Input Models:
24 Vin, power up 8.8 V, down 8.0 V
48 Vin, power up 17.0 V, down 16.0 V
Output
Output Voltage Trim • ±10%
Initial Set Accuracy • ±1% max (ICH100: ±1.5%)
Line Regulation • ±0.2% max measured from high line
to low line
Load Regulation • ±0.2% max measured from 0-100% load
Transient Response • 5% max deviation, recovery to within
1% in 500 µs, 25% step load change
Ripple & Noise • 3.3 & 5 V models: 100 mV pk-pk
12 & 15 V models: 150 mV pk-pk
24, 28 & 48 V models: 1% max pk-pk
ICH50/75 - 3.3 V, 5 V models: 75 mV
12 V, 15 V models: 100 mV
20 MHz bandwidth (see note 3)
Overvoltage Protection • 115-140%
Short Circuit Protection • ICH50/75/100W/IFH200-: Trip & restart
(hiccup mode) with auto recovery
ICH50W/75W/100/150 & IFH200: Current
limit, auto recovery
Temperature • ±0.03%/°C
Coefficient
Current Limit • IFH200: 110-150% nominal output, all
other models: 110-160% nominal output
Remote On/Off • See note 1 & 2
Thermal Shutdown • ICH50/50W/75/75W/100/150:
Thermal shutdown when case temperature
reaches 100 °C, auto recovery when case
temperature < +60 °C
ICH100W/IFH200:
Thermal shutdown when case temperature
reaches 105 °C, auto recovery when case
temperature <+90 °C
xppower.com
General
Efficiency • See tables
Isolation Voltage • 1500 VDC Input to Output
1500 VDC Input to Case
1500 VDC Output to Case
Isolation Resistance • 107 ohms min
Switching Frequency • ICH50/75 12-24V models: 400 kHz typical
ICH50/75 48 V models: 300 kHz typical
ICH50W/75W: 300 kHz typical
ICH100/ICH150: 500 kHz typical
ICH100W: 250 kHz typical
IFH200: 350 kHz typical
Power Density • ICH50: 18.3 W/in3
ICH75: 27.4 W/in3
ICH100: 36.6 W/in3
ICH150: 54.8 W/in3
IFH200: 34.8 W/in3
MTBF • ≥790 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Case • -40 °C to +100 °C, see derating curve
Temperature
Storage Temperature • ICH50/75: -55 °C to +105 °C
ICH100/150 & IFH200: -40 °C to +105 °C
Shock • 30 g pk, half sine wave for 18 ms, 3 pulses
per face, all 6 faces tested on all 3 axes
Vibration • 5-500 Hz at 3 g, 10 mins per axis
EMC & Safety
Emissions • EN55032, level A conducted with external
components
ESD Immunity • EN61000-4-2, level 2 Perf Criteria A
EFT/Burst • EN61000-4-4, level 1, Perf Criteria A
Surge • EN61000-4-5, installation class 1,
Perf Criteria A
Conducted Immunity • EN61000-4-6, 3 V rms Perf Criteria A
Magnetic Field • EN61000-4-8, 1 A/m, Perf Criteria A
Safety Approvals • UL60950-1