LLE Series
DESCRIPTION
The enhanced series of liquid level sensors incorporates a
photo-transistor trigger which provides a digital output that
denotes the presence or absence of liquid.
The mode of operation is derived from the principle of total
internal reflection. An LED and photo-transistor are housed
within a plastic dome at the head of the device. When no
liquid is present, light from the LED is internally reflected from
the dome to the photo-transistor. When liquid covers the
dome, the effective refractive index at the dome-liquid
boundary changes, allowing some light from the LED to
escape. Thus the amount of light received by the photo-
transistor is reduced and the output switches, indicating the
presence of liquid. This method of liquid level sensing is very
fast, and almost instantaneous for water.
FEATURES
• Solid state technology
• Small size
• Digital output
• Pre-wired
• Electrically robust
TYPICAL APPLICATIONS
• Home appliances
• Spa baths
• Vending machines
• Food and beverage
• Medical
• Compressors
• Machine tools
• Automotive
Liquid level sensors
BENEFITS
• Accurate, repeatable switching point
• Can be mounted in applications where space is limited
• Microprocessor compatible
• Easy to install, saving assembly time
• Reverse polarity, over voltage, short circuit and transient
protection
ORDER GUIDE
Catalogue Listing
Description Standard temperature High temperature
(Type 1) LLE101000 LLE101101
Screw In, M12 Thread, Plastic (Type 2) LLE102000 LLE102101
(Type 3) LLE103000 LLE103101
Push In, Plastic (Type 5) LLE105000 LLE105100
Screw In, ½ in, Metal Nickel plated brass LLE205000 LLE205100
Stainless steel LLE305000 LLE305100
LLE Series
2 www.honeywell.com/sensing
TECHNICAL INFORMATION
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
Operation mode User defined single point on/off switch (Output is high in air)
Repeatability (mm) ± 1
Hysteresis (mm) 2 (dependent on liquid)
Response time Rising liquid level - 50 µs
Falling liquid level - 1 s max (in ethanol)
Response in other liquids dependent on viscosity
MM
MM
Mechanicalechanical
echanicalechanical
echanical
Mounting Type 1 and 2 - mounted from outside; Type 3 and 5 - mounted from inside
Termination 250 mm flying leads (180 mm for metal versions)
Blue 0 V
Red +5 V to +12 V supply
Green Output
Material [Note 1] Polysulphone
Dimensions PlasticPlastic
PlasticPlastic
Plastic MetalMetal
MetalMetal
Metal
LLE101/102/103 SeriesLLE101/102/103 Series
LLE101/102/103 SeriesLLE101/102/103 Series
LLE101/102/103 Series LLE205/305 SeriesLLE205/305 Series
LLE205/305 SeriesLLE205/305 Series
LLE205/305 Series
Dome 3,5 mm radius (includes LLE105 Series)
Thread M12x1 ½ in BSPT
Hex 19 mm 24 mm (See mounting drawings on page 3)
EnvirEnvir
EnvirEnvir
Environmentalonmental
onmentalonmental
onmental SS
SS
Standartandar
tandartandar
tandard temperaturd temperatur
d temperaturd temperatur
d temperaturee
ee
eHigh temperaturHigh temperatur
High temperaturHigh temperatur
High temperaturee
ee
e
Operating temperature (°C) -25 to 80 (-13 °F to 176 °F) -40 to 125 (-40 °F to 257 °F)
Storage temperature (°C) -30 to 85 (-22 °F to 185 °F) -40 to 125 (-40 °F to 257 °F)
Thermal testing As per BS EN60068-2-33
Humidity As per BS EN60068-2-30
Vibration As per BS EN60068-2-6 Part S3: 1996
Mechanical shock As per BS EN60068-2-27 Part 2 Ea: 1987
Pressure range (bar) 0 to 5 (plastic housing) [Note 2]
0 to 25 (metal housing)
Ambient IR light limit (@ 940 nm) [Note 3] 10 mW/cm2 in operation
ElectricalElectrical
ElectricalElectrical
Electrical SS
SS
Standartandar
tandartandar
tandard temperaturd temperatur
d temperaturd temperatur
d temperaturee
ee
eHigh temperaturHigh temperatur
High temperaturHigh temperatur
High temperaturee
ee
e
Supply voltage (Vcc) +5 Vdc to +12 Vdc ± 5 %
Supply current (mA) 15 mA nominal @ +5 Vdc 5 mA nominal @ +5 Vdc
Output sink current [Note 4] @ 25 °C 10 mA max. @ 25 °C 40 mA max.
@ 5 Vdc supply @ 80 °C 3 mA max. @ 125 °C 7 mA max.
Notes:Notes:
Notes:Notes:
Notes:
[Note 1] Material compatibility information available on request.
[Note 2] Threaded sensors only.
[Note 3] For other ambient light environments the user should test the sensor under application conditions to verify compatibility.
[Note 4] The output is intended as a TTL compatible output signal, for interfacing to logic systems. For interfacing with other types of circuitry an appropriate buffer circuit
must be used.
Liquid level sensors
Honeywell Sensing and Control 3
MOUNTING DRAWING (IN MM AND INCHES)
19,00
(0.75)
22,49
(0.89)
19,40
(0.76)
12,45
(0.49)
4,70
(0.19)
M12 x 1 - 8 g
0,22 mm
Tinned Ends
2
(0.01 in )
2
Ø10,00
+0,10
-0
4,1
(0.16)
13,0
(0.51)
2,3
(0.09)
16,12
(0.63)
0,22 mm
Tinned Ends
2
(0.01 in )
+0.004
-0
(0.39 )
2
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
;y
Vcc
RED
OUTPUT
GREEN
SCHMITT
TRIGGER
PHOTO
TRANSISTOR
0 V
BLUE
IRED
VOLTAGE
REGULATOR
ELECTRICAL DIAGRAM
Notes
1 Recommended panel hole size Ø 12,5
±0.3 mm (0.49 ±0.01 in)
2 ‘O’ ring seal supplied Unassembled
LLE102000/LLE102101
(Type 2)
LLE105000/LLE105100
(Type 5)
19,00
(0.75)
M12 x 1 - 8 g
"L"
12,40
(0.49)
10,25
(0.40)
4,70
(0.19)
0,22 mm
2
(0.01 in
2
)
Tinned Ends
19,00
(0.75)
0,22 mm
2
(0.01 in
2)
Tinned Ends
"L"
7,20
(0.28)
10,30
(0.41)
2,70
(0.11)
M12 x 1 - 8 g
LLE101000/LLE101101
(Type 1)
LLE103000/LLE103101
(Type 3)
Cable length 12,3
(0.49)
16,00
(0.63)
24,00
(0.94)
24,00
(0.94)
45,4
(1.79)
16,5
(0.65)
Thread 1/2" BSP
Ø 14,5
0.57
0,22 mm2 (0.01 in2)
Tinned Ends
LLE205000/LLE205100
LLE305000/LLE305100
Automation and Control Solutions
Sensing and Control
Honeywell
Newhouse Industrial Estate
Motherwell, ML1 5SB, UK
www.honeywell.com
100437-EN UK07 GLO
Issue 3 June 2005
Copyright 2001-2005 Honeywell International Inc.
SALES AND SERVICE
Honeywell serves its customers through
a worldwide network of sales offices,
representatives and distributors. For
application assistance, current
specifications, pricing or name of the
nearest Authorized Distributor, contact
your local sales office or:
E-mail: E-mail:
E-mail: E-mail:
E-mail: info.sc@honeywell.com
InterInter
InterInter
Internet:net:
net:net:
net: www.honeywell.com/sensing
Phone and Fax:Phone and Fax:
Phone and Fax:Phone and Fax:
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
WARRANTY/REMEDY
Honeywell warrants goods of its
manufacture as being free of defective
materials and faulty workmanship.
Honeywell’s standard product warranty
applies unless agreed to otherwise by
Honeywell in writing; please refer to
your order acknowledgement or consult
your local sales office for specific
warranty details. If warranted goods are
returned to Honeywell during the period
of coverage, Honeywell will repair or
replace, at its option, without charge
those items it finds defective. TheThe
TheThe
The
forfor
forfor
foregoing is buyeregoing is buyer
egoing is buyeregoing is buyer
egoing is buyer
s sole rs sole r
s sole rs sole r
s sole remedy andemedy and
emedy andemedy and
emedy and
is in lieu of all waris in lieu of all war
is in lieu of all waris in lieu of all war
is in lieu of all warranties, exprranties, expr
ranties, exprranties, expr
ranties, expressedessed
essedessed
essed
or implied, including those ofor implied, including those of
or implied, including those ofor implied, including those of
or implied, including those of
mermer
mermer
merchantability and fitness for achantability and fitness for a
chantability and fitness for achantability and fitness for a
chantability and fitness for a
parpar
parpar
particular purpose. In no event shallticular purpose. In no event shall
ticular purpose. In no event shallticular purpose. In no event shall
ticular purpose. In no event shall
Honeywell be liable forHoneywell be liable for
Honeywell be liable forHoneywell be liable for
Honeywell be liable for
consequential, special, or indirconsequential, special, or indir
consequential, special, or indirconsequential, special, or indir
consequential, special, or indirectect
ectect
ect
damages.damages.
damages.damages.
damages.
While we provide application
assistance personally, through our
literature and the Honeywell web site, it
is up to the customer to determine the
suitability of the product in the
application.
Specifications may change without
notice. The information we supply is
believed to be accurate and reliable as
of this printing. However, we assume no
responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety
or emergency stop devices or in any
other application where failure of the
product could result in personal injury.
Failure to comply with these
instructions could result in death or
serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this
product sheet is for reference only.
Do not use this document as a
product installation guide.
Complete installation, operation, and
maintenance information is provided
in the instructions supplied with each
product.
Failure to comply with these
instructions could result in death or
serious injury.