Digital Fiber Sensors
E3X-DA-S/MDA
OMRON’s Next-generation Platform
for a Wide Range of Detection
Features a Power Tuning function that optimizes light
reception at the press of a button.
Combines newly developed 4-element LEDs with an APC
circuit to ensure stable, long-term LED performance.
Utilizes OMRON’s innovative wire-saving connector.
2-channel models achieve the thinnest profile in the
industry, at only 5 mm per channel.
2-channel models also offer AND/OR control output.
Be sure to read Safety Precautions on
page 15.
Features
Equipped with an Industry’s First Power Tuning (Optimum Light Setting) Function
The E3X-DA-S/MDA features a Power Tuning function that optimizes
power at the press of a button.
This function easily but securely resolves saturation due to short
sensing distances or insufficient incident light due to long sensing
distances.
In addition, the response speed does not change as mode selection
has tuned the power.
Adoption of Newly Developed 4-Element LEDs and an APC (Auto Power Control) Circuit
Achieves Long-term Reliable Detection at the Highest Level in the Industry
The long-term reliable detection at the highest level in the industry is
achieved with the innovative APC circuit whose performance is
proved by E3X-DA-N series and the newly developed high-power
LEDs (4-element type) to ensure super stable, long-term LED
performance.
Stable performance is always available without the ON/OFF setting of
an APC circuit.
OMRON’s Innovative Wire-saving Connector Inherited from the E3X-DA-N
The amplifier units with connectors supply the power to slave connectors
via a master connector. This offers three following advantages.
Selected from various
power mode according to applications
Up to approx. 1/25 times
Up to approx.
5 times
Incident
level Low
Appropriate
Incident level
Threshold
Saturation
Saturation
High-speed mode
Short-range mode
Standard mode
Long-range mode
Super-long-range mode
Appropriate
Modeless
Press
Available without mode setting.
Press the MODE key once to
adjust high or low incident levels
to be appropriate.
Conventional New proposal
Conventional Newly developed
Time
No APC circuit No APC circuit
3-element LEDs + APC
4-element LEDs + APC
Incident level
Incident level
Time
Long-term
stability
1. Greatly reduced wiring work
2. Improved space usability due to the unnecessity of relay
connectors
3. Simple stock management due to the unnecessity of
distinction between master and slave for amplifiers
Wire-saving Connector Model
Reduced Wiring and Space Requirements for Power Lines
Optical
communications
Power supply pin
Relay connector
Relay connector installation work, cost and space are saved.
No relay connector required
Amplifier units with connectors
Amplifier units with cables
<When using 5 amplifier units>
The power is
supplied from a
master unit to
slave units via a
master connector.
Power and output
lines are required
respectively.
Up to 16 amplifier units connectable
Master connector
Slave connector
Only output lines
Power line
Output lines
Power lines
Clear 7 lines
15 lines
1
E3X-DA-S/MDA
Industry Leading Two Amplifiers Loaded in a Small Body
Two amplifiers are loaded in a 10 mm-wide body.
Space usability can be approximately doubled.
In addition, approximately 40% of the energy can be
saved.
(compared to the value per channel of the former
model)
Simpler Digital Fiber Sensors
Required performance and functions have been reviewed from basic points to improve high-performance
but hard-to-use digital models. Digital fiber sensors, used in the sense as if using volume type sensors,
are added to the basic functions such as an APC function and digital display.
High-speed and High-resolution Analog Output Supports Wide Variety of Applications
Analog Control Output
The voltage in the range of 1 to 5 V is output according to the incident
level (digital display). Wide variety of applications is possible including
positioning control or difference detection with multiple levels.
High-speed and High Resolution
Detection modes can be switched in accordance with applications.
High-speed response of 80 Ps (super-high-speed mode) supports the
positioning controls that require high-speed control.
Area Output Function Area Judgment Is Possible
Only one sensor is enough for area judgment for height or others that has re-
quired multiple sensors.
Setting two threshold values allows easy output inside and outside range.
Remote Input Function Sensors Controlled from Outside
Remote settings for teaching/power tuning/light OFF are possible with input signals.
The remote input function meets the diversifying demands such as remote settings made for frequent teaching
due to level change corresponding to workpiece change or remote operation check of sensors before operation.
Equipped with an Industry's First ATC Function that Resolves Problems
at Manufacturing Sites
OMRON’s unique algorism is equipped to
distinguish dust or dirt and the change of
workpieces. Automatic correction of threshold
values by sensors in accordance with changes
prevents malfunctions and improves the operating
rates of machines. The ATC function is especially
effective for the applications that require high-
resolution detection.
Models available for a wide variety of applications at manufacturing sites
. . . . 2-channel models
Liquid crystal board installation and alignment check
20mm 10mm
2-channel models
E3X-MDA
Current value Threshold value
Key lock switch
Operation mode
selection switch
Threshold value adjustment
Threshold value teaching
Yes/No: Teaching at two points to be detected
Automatic: Automatic teaching by feeding workpieces
UP/DOWN keys
TEACH key
. . . . Simple & Easy Single-function Models
. . . .Advanced Analog
Output Models
ON/OFF
Analog
Sheet Displacement
Area Output Tablet length detection
2000
1000
Threshold
value 1
Threshold
value 2
Output
ON
OFF
Incident
level
Time
. . . .
Advanced, Twin-
output Models
Sticker detection
. . . .Advanced, External-
input Models
. . . .Advanced ATC Models
Fixed Threshold Value Method (Conventional Models)
2000
Incident level
(digital value)
Incident level
(digital value)
ON
Output OFF
ON
Output OFF
Corrected Threshold Value Method (ATC Models)
2000 10%
Threshold value is corrected every 30 seconds
*
Malfunctions are prevented
Threshold value
setasa relative
value
Time
1800
Time
Threshold value
set as an
absolute value
Malfunction Adjustment is required
* Monitoring range is defined in sensors according to threshold
values. Threshold values are corrected in this definition ran
g
e.
2
E3X-DA-S/MDA
Ordering Information
Amplifier Units
Amplifier Units with Cables
Amplifier Units with Connectors
Ratings and Specifications
Item Appearance Functions Model
NPN output PNP output
Single-function models --- E3X-DA11SE-S E3X-DA41SE-S
Standard models
Timer, Response speed change
E3X-DA11-S E3X-DA41-S
Mark-detecting models
(multiple color light sourc-
es)
Green LED E3X-DAG11-S E3X-DAG41-S
Blue LED E3X-DAB11-S E3X-DAB41-S
Infrared LED E3X-DAH11-S E3X-DAH41-S
Advanced models
External-in-
put models
Remote setting, counter, differential
operation E3X-DA11RM-S E3X-DA41RM-S
Twin-output
models
Area output, self-diagnosis, differential
operation E3X-DA11TW-S E3X-DA41TW-S
ATC function
models
ATC (Threshold value automatic correc-
tion) E3X-DA11AT-S E3X-DA41AT-S
Analog output
models Analog output models E3X-DA11AN-S E3X-DA41AN-S
2-channel models AND/OR output E3X-MDA11 E3X-MDA41
Item Appearance Functions Model
NPN output PNP output
Single-function models --- E3X-DA6SE-S E3X-DA8SE-S
Standard models
Timer, Response speed change
E3X-DA6-S E3X-DA8-S
Mark-detecting models
(multiple color light sourc-
es)
Green LED E3X-DAG6-S E3X-DAG8-S
Blue LED E3X-DAB6-S E3X-DAB8-S
Infrared LED E3X-DAH6-S E3X-DAH8-S
Advanced models
External-in-
put models
Remote setting, counter, differential
operation E3X-DA6RM-S E3X-DA8RM-S
Twin-output
models
Area output, self-diagnosis, differential
operation E3X-DA6TW-S E3X-DA8TW-S
ATC function
models
ATC (Threshold value automatic cor-
rection) E3X-DA6AT-S E3X-DA8AT-S
2-channel models AND/OR output E3X-MDA6 E3X-MDA8
Light
source
Response
time
Control output/input Functions
ON/OFF
output Input Analog
output
Power
tuning Timer
Interference
prevention
Differential
detection
counter
ATC
Single-function models
Red LED 1ms Only
main --- --- --- --- --- --- ---
Standard models
50
P
s to 4ms
Mark-de-
tecting
models
E3X-DA@G-S Green LED
50
P
s to 4ms
Only
main --- --- --- --- ---3X-DA@B-S Blue LED
E3X-DA@H-S Infrared LED
Ad-
vanced
models
Twin-output
models
Red LED
50
P
s to 4ms
Only
main
(1 line)
---
---
External-in-
put models
80
P
s to 4ms
Main +
sub
(2 lines) --- ---
ATC function
models
130
P
s to 4ms
Analog output
80
P
s to 4ms
Only
main (1 line) --- ---
2-channel models Red LED
130
P
s to 4ms
Main + main
(2 indepen-
dent lines)
--- --- --- --- ---
3
E3X-DA-S/MDA
Amplifier Unit Connectors (Order Separately)
Mobile Console (Order Separately)
Note: Use the E3X-MC11-SV2 Mobile Console for the E3X-DA-S/MDA-series Amplifier Units.
The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model.
Accessories (Order Separately)
Mounting Bracket End Plate
Item Appearance Cable
length
No. of con-
ductors Model
Master Connector
2 m
3E3X-CN11
4E3X-CN21
Slave Connector
1E3X-CN12
2E3X-CN22
Combining Amplifier Units and Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order.
When Using 5 Amplifier Units
Amplifier Unit Applicable Connector (Order Separately)
Model NPN output PNP output Master Connector Slave Connector
Single-function models
E3X-DA6SE-S E3X-DA8SE-S
+ E3X-CN11 E3X-CN12
Standard models E3X-DA6-S E3X-DA8-S
Mark-detecting
models
(multiple color light
sources)
E3X-DAG6-S E3X-DAG8-S
E3X-DAB6-S E3X-DAB8-S
E3X-DAH6-S E3X-DAH8-S
Advanced models
E3X-DA6TW-S E3X-DA8TW-S
E3X-CN21 E3X-CN22
E3X-DA6RM-S E3X-DA8RM-S
E3X-DA6AT-S E3X-DA8AT-S
2-channel models E3X-MDA6 E3X-MDA8
Amplifier Units (5 Units) + 1 Master Connector + 4 Slave Connectors
Appearance Model Remarks
E3X-MC11-SV2
(model number of set)
Mobile Console with Head,
Cable, and AC adapter pro-
vided as accessories
E3X-MC11-C1-SV2 Mobile Console
E3X-MC11-H1 Head
E39-Z12-1 Cable (1.5 m)
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
4
E3X-DA-S/MDA
Ratings and Specifications Refer to pages 17 to 20 for dimensions.
Amplifier Units
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 μs, reset: 55 μs.
*3. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
Type Single-function
models
Standard
models
Mark-detecting models (multiple color light sources)
Green LED Blue LED Infrared LED
Item Model E3X-DA@SE-S E3X-DA@-S E3X-DAG@-S E3X-DAB@-S E3X-DAH@-S
Light source (wavelength) Red LED (635 nm) Green LED (525 nm) Blue LED (470 nm)
Infrared LED (870nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Protection circuits Reverse polarity for power supply connection, output short-circuit
Response
time
Super-high-speed mode
--- Operate: 48 μs, reset: 50 μs*1, *2
High-speed mode
--- Operate/reset: 250 μs
Standard mode Operate or reset: 1 ms
High-resolution mode
--- Operate or reset: 4 ms
Sensitivity setting Teaching or manual method
Functions
Power tuning --- Light emission power and reception gain, digital control method
Timer function ---
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power
control (APC) High-speed control method for emission current
Zero-reset --- Negative values can be displayed. (Threshold value is shifted.)
Initial reset Settings can be returned to defaults as required.
Mutual interfer-
ence prevention Possible for up to 10 Units *3
Display Operation indicator
(orange) Operation indicator (orange), Power Tuning indicator (orange)
Digital display incident level +
threshold Select from incident level + threshold or other 6 patterns
Display orientation --- Switching between normal/reversed display is possible.
Ambient illumination
(Receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature range
Operating: Groups of 1 to 2 Amplifiers: 25°C to 55°C
Groups of 3 to 10 Amplifiers: 25°C to 50°C
Groups of 11 to 16 Amplifiers: 25°C to 45°C
Storage: 30°C to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired or amplifier unit connector
Weight (packed state) Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction manual
5
E3X-DA-S/MDA
*1. Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention
and the Mobile Console will not function.
*2. PNP output is as follows: Operate: 53 Ps, reset: 55 Ps.
*3. When counter is enabled: 80 Ps for operate and reset respectively.
*4. When differential output is selected for the output setting, the second channel output is 200 Ps for operation and reset respectively.
*5. Mutual interference prevention can be used for only up to 6 Units if power tuning is enabled.
*6. Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled.
Type Advanced models 2-channel models
External input
models Twin output models ATC function models
Analog output models
Item Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S E3X-MDA@
Light source (wavelength) Red LED (635 nm)
Power supply voltage 12 to 24 VDC 10%, ripple (p-p) 10% max.
Power consumption 1,080mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Control
output
ON/OFF output Load power supply voltage: 26.4 VDC; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 1 V max.
Analog output ---
Control output
Voltage output: 1 to
5 VDC
(Connection load 10
k: min.)
Temperature char-
acteristics
0.3%F.S./C
Response speed/
repeat accuracy
Super-high-speed mode:
80
P
s/1.5%F.S.
High-speed mode:
250
P
s/1.5%F.S.
Standard mode:
1 ms/1%F.S.
High-resolution mode:
4 ms/0.75%F.S.
---
Protection circuits Reverse polarity for power supply connection, output short-circuit
Response
time
Super-high-speed mode
Operate: 48 Ps,
reset: 50 Ps*1, *2, *3
Operate or reset:
80Ps*1
Operate or reset:
130 Ps*1
Operate or reset:
80 Ps*1
Operate or reset:
130 Ps*1, *4
High-speed mode
Operate or reset: 250 Ps
Operate or reset: 450
P
s
Standard mode Operate or reset: 1ms
High-resolution mode
Operate or reset: 4ms
Sensitivity setting Teaching or manual method
Functions
Power tuning Light emission power and reception gain, digital control method
Differential de-
tection
Switchable between single edge and double edge detection mode
Single edge: Can be set to 250 Ps, 500 Ps, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 Ps, 1 ms, 2 ms, 20 ms, or 200 ms.
---
Timer function
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-
ms increments, and 1 to 5 s set in 1 s-increments)
Automatic power
control (APC) High-speed control method for emission current
Zero-reset Negative values can be displayed. (Threshold value is shifted.)
Initial reset Settings can be returned to defaults as required.
Mutual interfer-
ence prevention Possible for up to 10 Units *5
Possible for up to 9
Units (18 channels) *6
Counter
Switchable between
up counter and down
counter.
Set count:
0 to 9,999,999
---
I/O setting
External input set-
ting (Select from
teaching, power tun-
ing, zero reset, light
OFF, or counter re-
set.)
Output setting
(Select from channel
2 output, area out-
put, or self-diagno-
sis.)
Output setting (Se-
lect from channel 2
output, area output,
self-diagnosis out-
put, or ATC error
output)
Analog output set-
ting (offset voltage
adjustable)
Output setting
(Select from channel
2 output, AND, OR,
leading edge sync,
falling edge sync, or
differential output)
Display
Operation indicator
(orange), Power
Tuning indicator (or-
ange)
Operation indicator for channel 1 (orange),
Operation indicator for channel 2 (orange)
Operation indicator
(orange),
Power Tuning indi-
cator (orange)
Operation indicator for
channel 1 (orange),
Operation indicator for
channel 2 (orange)
6
E3X-DA-S/MDA
Type Advanced models 2-channe models
External input models
Twin-output models
ATC function models
Analog output models
Item Model E3X-DA@RM-S E3X-DA@TW-S E3X-DA@AT-S E3X-DA@AN-S E3X-MDA@
Digital display
Select from incident
level + threshold or
other 7 patterns
Select from incident level + threshold or other 6 patterns
Select from incident
level for channel 1 +
incident level for
channel 2 or other 7
patterns
Display orientation Switching between normal/reversed display is possible.
Ambient illumination
(Receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Ambient temperature range
Operating: Groups of 1 to 2 Amplifiers: 25C to 55C
Groups of 3 to 10 Amplifiers: 25C to 50C
Groups of 11 to 16 Amplifiers: 25C to 45C
Storage: 30C to 70C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 M: min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection IEC 60529 IP50 (with Protective Cover attached)
Connection method Pre-wired or amplifier unit connector
Weight (packed state) Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate (PC)
Accessories Instruction manual
Amplifier Unit Connectors
Item Model E3X-CN11/21/22 E3X-CN12
Rated current 2.5 A
Rated voltage 50 V
Contact resistance
20 m: max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent Connec-
tor. It does not include the conductor resistance of the cable.)
No. of insertions
Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit
and the adjacent Connector.)
Mate-
rials
Housing Polybutylene terephthalate (PBT)
Contacts Phosphor bronze/gold-plated nickel
Weight
(packed state) Approx. 55 g Approx. 25 g
Mobile Console
Item Model E3X-MC11-SV2
Applicable
Sensors
E3X-DA-S
E3X-MDA
E3C-LDA
E2C-EDA
Power supply
voltage Charged with AC adapter
Connection
method Connected via adapter
Weight
(packed state)
Approx. 580 g (Console
only: 120 g)
Refer to Instruction Manual provided with
the Mobile Console for details.
7
E3X-DA-S/MDA
Sensing Distance
Through-beam Models (Unit: mm)
*1. The optical fiber for the E32-T17L is 10 m long on each side, so the value is 20,000 mm
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Standard
models
Flexible
(new
standard)
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R) 700 530 350 140 450 350 230 140
E32-T14LR/E32-T15YR/E32-T15ZR 270 210 130 50 170 130 85 50
E32-T21R/E32-T22R/E32-T222R/
E32-T25XR/E32-TC200FR(F4R) 160 130 75 30 100 75 50 30
E32-T24R/E32-T25YR/E32-T25ZR 60 50 25 10 35 27 18 10
Standard
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4) 1,000 760 500 200 650 500 330 200
E32-T14L/E32-T15Y/E32-T15Z 600 460 300 120 390 300 200 120
E32-TC200A 900 680 450 180 580 450 300 180
E32-TC200E/E32-T22/E32-T222/
E32-T25X/E32-TC200F(F4) 270 220 125 50 170 130 85 50
E32-T24/E32-T25Y/E32-T25Z 160 130 75 30 100 70 45 30
Break-
resistant
E32-T11/E32-T12B/E32-T15XB 900 680 450 180 580 450 300 180
E32-T21/E32-T221B/E32-T22B 240 200 110 45 150 110 70 45
E32-T25XB 180 150 85 35 125 95 60 35
Fluorine
coating E32-T11U 900 680 450 180 580 450 300 180
Special-
beam
models
Long-
distance,
high power
E32-T17L
20,000*1 20,000*1
10,000 4,000 13,000 10,000 6,500 4,000
E32-TC200 + E39-F1
4,000*24,000*2
2,600 1,500 4,000 3,700 2,400 1,500
E32-T11R + E39-F1
4,000*2
3,700 2,400 970 3,100 2,400 1,600 970
E32-T11 + E39-F1
4,000*2
3,600 2,300 930 3,000 2,300 1,500 930
E32-T14
4,000*2
3,400 2,250 900 2,900 2,200 1,450 900
E32-T11L/E32-T12L 1,700 1,330 870 350 1,100 870 580 350
E32-T11L + E39-F2 910 800 500 180 600 520 340 180
E32-T11R + E39-F2 520 400 250 100 330 260 170 100
E32-T11 + E39-F2 820 660 430 160 530 430 280 160
E32-T21L/E32-T22L 540 440 250 100 340 260 170 100
Ultracom-
pact,
ultrafine
sleeve
E32-T223R 160 130 75 30 110 85 55 30
E32-T33-S5 53 44 25 10 35 28 18 10
E32-T333-S5 1210648654
E32-T334-S5 65324322
Fine beam
E32-T22S 2,500 1,900 1,250 500 1,600 1,250 830 500
E32-T24S 1,750 1,300 870 350 1,100 870 580 350
Area sensing
E32-T16PR 1,100 840 560 220 730 560 370 220
E32-T16P 1,500 1,100 750 300 970 750 500 300
E32-T16JR 980 750 480 190 600 480 320 190
E32-T16J 1,300 1,000 650 260 800 650 430 260
E32-T16WR 1,700 1,300 850 340 1,100 860 570 340
E32-T16W 2,300 1,800 1,150 450 1,400 1,100 730 450
E32-T16 3,700 2,800 1,850 740 2,400 1,800 1,200 740
E32-M21 750 610 350 140 470 360 240 140
8
E3X-DA-S/MDA
* The optical fiber for the E32-T12F is 2 m long on each side, so the sensing distance is 4,000 mm.
Reflective Models (Unit: mm)
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Environ-
ment
resistive
models
Heat-
resistant
E32-T51 1,000 760 500 200 650 500 330 200
E32-T54 300 230 150 60 190 150 100 60
E32-T81R-S 360 280 180 70 230 180 120 70
E32-T61-S + E39-F2 600 450 300 120 390 300 200 120
E32-T61-S + E39-F1 4,000 3,400 2,200 900 3,000 2,200 1,450 900
E32-T84S-S 1,750 1,300 870 350 1,100 870 570 350
E32-T61-S 600 450 300 120 390 300 200 120
Chemical
resistant
E32-T11F 2,500 2,000 1,300 520 1,600 1,300 850 520
E32-T12F 4,000*3,000 2,000 800 2,600 2,000 1,300 800
E32-T14F 500 400 250 100 320 250 160 100
E32-T51F 1,800 1,400 900 350 1,190 920 600 350
E32-T81F-S 920 700 460 190 600 460 300 190
Vacuum
resistant
E32-T51V 260 200 130 50 170 130 85 50
E32-T51V + E39-F1V 1,350 1,000 680 260 850 650 430 260
E32-T54V 210 130 100 35 110 85 55 35
E32-T54V + E39-F1V 660 500 330 180 420 320 210 180
E32-T84SV 630 480 320 130 410 310 200 130
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Standard
models
Flexible
(new stan-
dard)
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R) 300 170 120 50 170 120 80 50
E32-D14LR 80 45 30 14 45 33 22 14
E32-D15YR/E32-D15ZR 70 40 26 12 40 29 19 12
E32-D211R/E32-D21R/E32-D22R/
E32-D25XR/E32-DC200FR(F4R) 50 30 20 8 30 22 14 8
E32-D24R 26 15 10 4 15 10 6 4
E32-D25YR/E32-D25ZR 14 8 5 2 8 5 3.3 2
Standard
E32-DC200/E32-D15X/
E32-DC200B(B4) 500 300 200 90 300 210 130 90
E32-D12 400 230 160 70 230 160 100 70
E32-D14L 200 110 80 36 110 80 50 36
E32-D15Y/E32-D15Z 170 100 65 30 100 70 45 30
E32-D211/E32-DC200E/E32-D22/
E32-D25X/E32-DC200F(F4) 130 80 50 22 80 55 35 22
E32-D24 50 30 20 8 30 22 14 8
E32-D25Y/E32-D25Z 35 20 12 6 20 14 9 6
Break-
resistant
E32-D11/E32-D15XB 300 170 120 50 170 125 80 50
E32-D21B/E32-D221B 110 70 45 20 70 50 30 20
E32-D21/E32-D22B 50 30 20 8 30 22 14 8
E32-D25XB 85 50 30 15 50 35 23 15
Fluorine
coating E32-D11U 300 170 120 50 170 125 80 50
9
E3X-DA-S/MDA
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Special-
beam
models
Long
distance,
high power
E32-D16
40 to
1,000
40
to
700
40 to
450
40
to
240
40
to
600
40
to
490
40 to
300
40
to
240
E32-D11L 650 400 260 110 400 270 180 110
E32-D21L/E32-D22L 210 130 80 35 130 85 55 35
Ultracom-
pact, ultrafine
sleeve
E32-D33 25 16 10 4 16 10 6 4
E32-D331 5 3 2 0.8 3 2 1.3 0.8
Coaxial/small
spot
E32-CC200R 250 150 100 45 150 105 65 45
E32-CC200 500 300 200 90 300 210 140 90
E32-D32L 250 150 100 45 150 100 65 45
E32-C31/E32-D32 120 75 50 22 75 50 30 22
E32-C42 + E39-F3A Spot diameter variable in the range 0.1 to 0.6 mm at distances in the
range 6 to 15 mm.
E32-D32 + E39-F3A Spot diameter variable in the range 0.5 to 1mm at distances in the range
6 to 15 mm.
E32-C41 + E39-F3A-5 0.1-mm dia. spot at a distance of 7 mm.
E32-C31 + E39-F3A-5 0.5-mm dia. spot at a distance of 7 mm.
E32-C41 + E39-F3B 0.2-mm dia. spot at a distance of 17 mm.
E32-C31 + E39-F3B 0.5-mm dia. spot at a distance of 17 mm.
E32-C31 + E39-F3C Spot diameter of 4 mm max. at distances in the range 0 to 20 mm.
Area sensing E32-D36P1 250 150 100 45 150 100 65 45
Retroireflec-
tive
E32-R21 + E39-R3 (provided) 10 to 250
E32-R16 + E39-R1 (provided) 150 to 1,500
Convergent-
reflective
E32-L25/E32-L25A 3.3
E32-L24S 0 to 4
E32-L24L 2 to 6 (center 4)
E32-L25L 5.4 to 9 (center 7.2)
E32-L86 4 to 10
E32-L16 0 to 15 0 to 12 0 to 15 0 to 12
Environ-
ment-
resistive
models
Heat-
resistant
E32-D51 400 230 160 72 230 165 110 72
E32-D81R-S
E32-D61-S 150 90 60 27 90 63 40 27
E32-D73-S 100 60 40 18 60 40 25 18
Chemical-
resistant
E32-D12F 160 95 65 30 95 70 45 30
E32-D14F 70 40 30 10 40 28 18 10
10
E3X-DA-S/MDA
Application-specific Models (Unit: mm)
* The optical fiber for the E32-T14 is 2 m long on each side, so the sensing distance is 4,000 mm.
Model E3X-DA@-S E3X-MDA@
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Applica-
tion-
specific
models
Label
detection
E32-G14 10
E32-T14 4,000*3,400 2,250 900 2,900 2,200 1,450 900
Liquid-level
detection
E32-L25T Applicable tube: Transparent tube with a diameter in the range 8 to 10
mm and a recommended wall thickness of 1 mm
E32-D36T Applicable tube: Transparent tube (no restriction on diameter)
E32-A01 Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm
and a recommended wall thickness of 1 mm
E32-A02 Applicable tube: Transparent tube with a diameter in the range 6 to 13
mm and a recommended wall thickness of 1 mm
E32-D82F1(F2) Liquid-contact model
Glass-
substrate
alignment
E32-L16 0 to 15 0 to 12 0 to 15 0 to 12
E32-A08 10 to 20 --- 10 to 20 ---
E32-A07E1(E2) 15 to 25 --- 15 to 25 ---
E32-L66 5 to 18 5 to 16 --- 5 to 18 5 to 14 ---
Glass-
substrate
Mapping
E32-A09/E32-A09H 15 to 38 --- 15 to 38 ---
E32-A09H2 20 to 30 --- 20 to 30 ---
Wafer
mapping
E32-A03/E32-A03-1 1,150 890 600 250 750 580 380 250
E32-T24S 1,750 1,300 870 350 1,100 870 580 350
E32-A04/E32-A04-1 460 340 225 100 300 220 145 100
11
E3X-DA-S/MDA
Green, Blue, and Infrared Light Sources (Unit: mm)
Model E3X-DAG@-S/DAB@-S E3X-DAH@-S
Type
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
High-
reso-
lution
mode
Stan-
dard
mode
High-
speed
mode
Super-
high-
speed
mode
Through-
beam
models
Standard
E32-T11R/E32-T12R/E32-T15XR/
E32-TC200BR(B4R) 65 50 35 30 280 190 130 55
E32-T14LR/E32-T15YR/
E32-T15ZR 25 20 22 12 100 75 80 21
E32-TC200/E32-T12/E32-T15X/
E32-TC200B(B4) 100 75 50 45 400 280 180 80
E32-T14L/E32-T15Y/E32-T15Z 50 40 30 25 240 160 110 45
Special beam E32-T11L/E32-T12L 150 120 85 75 700 490 320 140
Reflective
models
Standard
E32-D11R/E32-D12R/E32-D15XR/
E32-DC200BR(B4R) 17 14 10 8 120 90 60 21
E32-D14LR 4.4 3.5 2.5 2.2 32 24 16 5.5
E32-D15YR/E32-D15ZR 4.2 3.3 2.2 2.1 28 20 13 5
E32-DC200/E32-D15X/
E32-DC200B(B4) 32 25 16 16 200 150 100 35
E32-D14L 11 9 65.580604014
E32-D15Y/E32-D15Z 10 8 5.5 5 65 50 33 11
Special beam
E32-D11L 44 35 22 22 260 190 130 45
E32-CC200R 15 12 8 7.5 100 75 50 17
E32-CC200 32 25 16 16 200 150 100 35
E32-D32L 15 12 8 7.5 100 75 50 17
E32-C31/E32-D32 7.5 6 4 3.5 50 37 25 8.5
Applica-
tion-
specific
models
Label
detection
E32-T14 320 260 220 160 1,800 1,200 820 360
E32-G14 10 10
Refer to E32 Series for details on Fiber Units.
12
E3X-DA-S/MDA
Dimensions (Unit: mm)
Amplifier Units
Main display Sub-display Vinyl-insulated round cable
Standard length: 2 m*
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
*Cable Specifications
CH1
CH2
Operation indicator
Amplifier Units with Cables
E3X-DA11-S
E3X-DA41-S
E3X-DAG11-S
E3X-DAG41-S
E3X-DAB11-S
E3X-DAB41-S
E3X-DA11RM-S
E3X-DA41RM-S
E3X-DA11TW-S
E3X-DA41TW-S
E3X-DA11SE-S
E3X-DA41SE-S
E3X-DA11AT-S
E3X-DA41AT-S
E3X-DA11AN-S
E3X-DA41AN-S
E3X-MDA11
E3X-MDA41
Four, 2.4 dia.
4.5
10
7
5.65
4.5
3.4
4.3 70
32
12.5
9.9
16
34.8
28.1
18.7
44.3 Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2 dia. holes
Hole for optical communications
10
Two, 2.4 dia.
4.5
5.65
3.9 × 3
=11.7
12.15
15.1
32.8
3.25
29.8
3.9 × 3 = 11.7
3.4 4.4
1628.1
16
A *
Two, M3
* The Mounting Bracket can also
be used on this side.
With Mounting Bracket Attached
Mounting Holes
(E3X-DA@-S) (E3X-MDA@)
(E3X-DA@-S) (E3X-MDA@)
E3X-DA11-S
-DA41-S
-DAG11-S
-DAG41-S
-DAB11-S
-DAB41-S
4-dia., 3-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
E3X-DA11TW-S
-DA41TW-S
-DA11RM-S
-DA41RM-S
4-dia., 4-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter, 1.1 mm)
E3X-MDA11
-MDA41
4-dia., 2-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
17
E3X-DA-S/MDA
7
4.5
10
5.65
4.5
Four, 2.4 dia.
3.4
3.9 × 3
=11.75
12.15
15.1
32.8
3.25
29.8
3.9 × 3 = 11.7
A*1
4.3 70 8.1
32
12.95
9.9
16
34.8
28.1
18.7
44.3 Mounting Bracket (E39-L143)
SUS304 stainless steel
Two, 3.2-dia. holes
3.4 4.4
16
Two, M3
10
Two, 2.4 dia.
4.5
5.65
Connector
Dia. A*2
*1 The Mounting Bracket can also be
used on this side.
*2 Cable Diameters
1628.1
Hole for optical communications
CH1
CH2
Main display Sub-display
Round ( ): Power tuning indicator
Oblong ( ): Operation indicator for channel 2
Operation indicator
Amplifier Units with
C
onnectors
E3X-DA6-S
E3X-DA8-S
E3X-DAG6-S
E3X-DAG8-S
E3X-DAB6-S
E3X-DAB8-S
E3X-DA6RM-S
E3X-DA8RM-S
E3X-DA6TW-S
E3X-DA8TW-S
E3X-DA6SE-S
E3X-DA8SE-S
E3X-DA6AT-S
E3X-DA8AT-S
E3X-MDA6
E3X-MDA8
(E3X-DA@-S) (E3X-MDA@)
With Mounting Bracket Attached
Mounting Holes
(E3X-DA@-S) (E3X-MDA@)
E3X-CN22
(2 conductors)
E3X-CN21
(4 conductors)
E3X-CN11
(3 conductors)
4.0-mm
dia.
E3X-CN12
(1 conductor)
2.6-mm