9:1 Transmission Line Step-up Transformer
5-220MHz MABA-007488-CT9550
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1P
2
RoHS
Compliant
Electrical Specifications: TA = 25°C, Z0 = 75 Ω
Recommended PCB Configuration Absolute Maximum Ratings 1,2
Parameter Absolute Maximum
Max Input Power 250mW
DC current 30mA
Operating Temperature -20°C to +85°C
Storage Temperature -55°C to +100°C
1. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2. M/A-COM does not recommend sustained operation near
these survivability limits.
Parameter Units Typical Minimum Maximum
Frequency Range 5-220 MHz
Insertion Loss 1 {From Pin 6 to 1 & From Pin 4 to 3}
(Short Connections) 5 - 155 MHz
155-220 MHz
dB
dB
0.2
0.8
—
—
0.5
1.0
Amplitude Imbalance 1 5 - 55 MHz
55 –155 MHz
155 –220 MHz
dB
dB
dB
0.03
0.04
0.14
—
—
—
0.2
0.3
0.5
Phase Imbalance 1 5-55 MHz
55 –155 MHz
155 –220 MHz
º
º
º
0.5
1.1
1.5
—
—
—
1.0
2.0
2.5
Insertion Loss 2 {From Pin 6 to 3 & From Pin 4 to 1}
(Cross connections) 5 - 55 MHz
55-100 MHz
100-220 MHz
dB
dB
dB
0.8
1.0
1.4
—
—
—
1.0
1.2
1.8
Amplitude Imbalance 2 5 - 55 MHz
55 –155 MHz
155 –220 MHz
dB
dB
dB
0.03
0.04
0.14
—
—
—
0.2
0.3
0.5
Phase Imbalance 2 5-55 MHz
55 –100 MHz
100 –220 MHz
º
º
º
1.0
1.4
2.5
—
—
—
2.0
3.0
4.0
Input Return Loss 5-220 MHz dB 10 8 —