Anderson Power Products®
®
SPEC Pak®
Solar Power | Wind Power | DC Lighting | Inverters | Micro Inverters | Battery Back up
LED Lighting | Solar Panels | Combiner Boxes | Hydro-Electricity | Harsh Environments
Sealed Power For Environmental Connections
www.andersonpower.com
- 2 -
Configurable to 1000 Volts
1 - Chemical & UV Resistant Ruggedized Shells
• Wire to wire configurations
• Panel mount configurations
2 - Touch Safe Housings (UL1977, Section 10.2)
3 - IP68 Interfacial Sealing Gasket
4 - Locking Latch (NEC 2008, Section 690.33C)
5 - Power Contacts (up to 4) and / or Signal Contacts (up to 16)
6 - Uses Industry Standard Sealing Components
(PG gland compatible - size 16)
7 - First Mate / Last Break Ground Contacts
(NEC 2008, Section 690.33D)
8 -
Housing Colors to Match Wire Colors for ease of Assembly
9 - Unlocking Tool
Rugged and Sealed
(IP68) Plugs and Receptacles
For Use with APP® Powerpole® Signal, Power & Ground Contacts & Housings
APP®’s Solar SPEC Pak® Connector Series uses rugged and environmentally sealed (IP68) shells to protect industry leading APP® Powerpole®
contacts and housing. Customer configured Solar SPEC Pak® is designed specifically to meet the requirements of the photovoltaic industry
conforming to NEC 2008 requirements for first make/last break ground and a locking feature that require a tool to unlock. It’s also the first multipole
connector to conform to UL 6703A. The adaptive design lends itself towards use in other markets including wind power, fuel cells, mass transporta-
tion, off-road vehicles, agricultural equipment, oil and petro chemical exploration and many more.
The core APP® Powerpole® technology within the SPEC Pak® is proven reliable and cost effective. The broad selection of touch safe, color-coded
Powerpole®
housings with power, signal and ground contacts accept a broad range of wire gauges, #24 to #10 AWG (0.25 to 4.0 mm²), giving users
thousands of flexible design solutions in a single interconnect.
4
235
6
8
1
7
9
Specications
www.andersonpower.com - 3 -
Electrical
Current Rating (Amprese)
UL 1977 - 15 to 40 40 7
UL 6703A - 20 - -
CSA (30C Rise) - 10 to 26 35 5
Voltage Rating
UL 1977 (AC/DC) - 600 600 300
UL 6703A (AC) - 600 600 -
IEC 60664 (AC/DC) - 1,000 - -
Dielectric Withstanding (AC/DC) - 2,200 2,200 1,600
Contact Resistance Ω (average) - 525 525 -
Hot Plug 2 (UL 1977)
250 Cycles at 120V - 30 30 -
Mechanical
Environmental Seal
IP rating IP68 - - -
UL 50 Sec 36 Pass - - -
Wire Size - 20 to 10 AWG 14 to 10 AWG 24 to 20 AWG
- 0.5 to 4.0 mm² 1.5 to 4.0 mm² 0.25 to 0.5 mm²
Operating Temperature
UL 1977 -40° to 105°C -20° to 105°C -20° to 105°C -20° to 105°C
-40° to 221°F -4° to 221°F -4° to 221°F -4° to 221°F
UL 6703A -35° to 65°C - - -
-31° to 149°F - - -
Mating Cycles (no load)
Tin - 1,500 1,500 -
Silver - 10,000 - -
Gold - - - 5,000
Latch
Mating Cycles 200 - - -
Lock (NEC 2008 Sec 690.33C) Pass - - -
Contact Retention Force (lbf) - 25.0 25.0 12.0
(N) - 111.0 111.0 53.0
Insertion Force (lbf) - - 3.0 4.5 max
(N) - - 13.3 20.0 max
Touch Safe (UL 1977 Sec 10.2) - Pass - -
Mechanical Shock (50g) Mil Standard 202 213 Cond A Pass - -
Vibration (10g) Mil Standard 202 204 Cond A Pass - -
Materials
Shell / Housing PBT / PC PC PC PBT / PC
Powerpole® Holder PC - - -
Latch PPE - - -
Flammability (UL 94) V0 V0 V0 V0
Weatherability (UL 764C) F1 - - -
-35°C Impact Test (UL 6703A Sec 30) Pass - - -
Thermal Cycle Test (UL 6703A Sec 35) Pass - - -
Humidity Cycle Test (UL6703A Sec 36) Pass - - -
Contacts
Base - Copper Alloy Copper Alloy Copper Alloy
Plating - Tin or Silver Tin or Silver Gold, 50µ
Notes:
1. PPMX housing holds up to 2 pin and 2 sockets.
2. Hot Plug testing completed using individual Powerpole® housings and contacts,
not installed in SPEC Pak® shells.
For other industry test and/or agency approvals, contact customer service.
............................. SPEC Pak® Shells Used With ..........................
Powerpole® Power Powerpole® Ground PPMX 1 Signal
Contacts & Housings Contacts & Housings Contacts & Housings
SPEC Pak® Shell (1327FP Series) (1827 Series) (4800 Series)
Part Number Congurator
PART NUMBER PLAN
www.andersonpower.com
- 4 -
ORDERING INFORMATION
P K 2 - 050 B04
P = Solar K = Black 1 = Inline Receptacle 050 = 50 mm - 4 Pole Shell B04 = PP15/45 Housing (any type), 4 Pole
SPEC Pak® 2 = Panel Mount Receptacle
6 = Straight Plug
9 = Panel Mount Receptacle Cover
9R = Inline Receptacle Cover
9P = Plug Cover
SPEC Pak® Series Shell Color Shell Style Shell Size Insert Arrangement
(1 Fixed Character) (1 Character) (1 Character) Dash (mm) (3 Characters) (3 Characters)
SPEC Pak® Shell Kits
Part
Number Description
PK6-050B04 Plug shell kit
- Plug shell (includes interfacial sealing gasket)
- Powerpole® holder for plug
PK2-050B04 Panel mount receptacle shell kit
- Panel mount receptacle shell with locking latch
- Powerpole® holder for receptacle
- Panel mount gasket for receptacle
PK1-050B04 Inline receptacle shell kit
- Inline receptacle shell with locking latch
- Powerpole® holder for receptacle
PK9P-050 Cover kit for plug
- Protective sealing (IP68) cover with lanyard
- With locking latch
PK9-050 Cover kit for panel mount receptacle
- Protective sealing (IP68) cover with lanyard
PK9R-050 Cover kit for inline receptacle
- Protective sealing (IP68) cover with lanyard
Component Replacement Parts
Part
Number Description
114805P1 Panel mount gasket for receptacle
2-8709P1 4 position solar locking latch
PKT-050T01 4 position solar unlocking tool
(for use with locking latch)
INLINE
RECEPTACLE KIT
PANEL MOUNT
RECEPTACLE KIT
PLUG
KIT
NOTE:
- Mounting hardware (4 each - M3 or #4 screws) not included
- Recommended torque for mounting hardware is 2½ to 4 in-lbf (0.28 to 0.45 N)
Panel Mount
Receptacle
Shell
LatchPanel Mount Gasket
Receptacle
Powerpole®
Holder
Plug
Powerpole®
Holder
Plug Shell
Interfacial Sealing Gasket
Receptacle
Powerpole®
Holder
Inline Receptacle Shell
IP68 SEALING
COVER KIT
Latch
Plug
Cover
Receptacle
Cover
PART NUMBER PLAN
www.andersonpower.com - 5 -
00 = Custom Configuration - Use Next Section
01 = 261G2 Contact for #10 to #14 AWG (4.0 to 1.5 mm²) Wire
02 = 200G1L Contact for #10 to #14 AWG (4.0 to 1.5 mm²) Wire
03 = 261G1 Contact for #12 to #16 AWG (2.5 to 1.0 mm²) Wire
04 = 1331 Contact for #12 to #16 AWG (2.5 to 1.0 mm²) Wire
05 = 262G1 Contact for #16 to #20 AWG (1.0 to 0.5 mm²) Wire
06 = 1332 Contact for #16 to #20 AWG (1.0 to 0.5 mm²) Wire
99 = All Signal
Amperage ratings are available on page 9.
Housing
Wire Protection Arrangement Contact
See pages 6 & 7 For more information see pages 8 & 9 APP® Content
(4 Characters) Dash (1 Character) (2 Characters) Dash (3 Characters)
PS 01 - 0 00 - Leave Blank
00 = None 00 = None 0 = Custom Configuration - Use Next Section Custom Configuration*
PS = Plastic Short 01-99 = Varies By Gland Type A = AC, Single Phase Contact Factory
PF = Plastic With Flex Spring B = AC, 3 Phase, 3 Wire
PR = Plastic Right Angle C = DC, 2 Circuit, 4 Wire
PM = Plastic Multi Hole D = DC, 2 Wire, With Ground
CT = Conduit Adapter Threaded H = DC, 2 Wire, With 8 Signal
CA = Conduit Adapter Push-in J = AC, Single Phase, With 4 Signal
L = DC, 2 Wire, With 4 Signal
N = DC, 2 Wire, With Ground & 4 Signal
U = DC, 2 Wire
X = All Signal
NOTE:
1. See PG Gland charts on
page 6 & 7 for details.
2. Panel Mount receptacle
side is always “00”.
Part Numbering Notes:
1. To order SPEC Pak® Shell Kits Only (no internal Powerpole® housings or contacts), use part numbering on page 4 only. Plug Shell Kit
Example: PK6-050B04. Powerpole®
housings, contacts and wire protection may be ordered separately, see pages 6, 7 and 10 for information.
2. To order SPEC Pak® connectors kits (including internal Powerpole® housings and contacts) use Part Number Plan across the top of pages 4
and 5. Standard SPEC Pak® Plug Configuration Example: PK6-050B04PS01-B01
3. To order a custom configuration which is not listed on page 8 and 9, use custom part number configurator on the APP® website,
www.andersonpower.com or contact factory.
* Custom configuration may not be UL Recognized.
Wire Protection - PG Gland
www.andersonpower.com
- 6 -
STRAIGHT PLASTIC WITH FLEX SPRING - STD PACK 50 / UL LISTED
STRAIGHT PLASTIC SHORT THREAD TYPE - STD PACK 50 / UL LISTED
SPECIFICATIONS
Washer Body Seal Sealing Nut
C1
C2
Wire Protection Cable Range Thread O. D. Panel Thread Length Wrench Size Wrench Size
Designation Wire Outer Dia. C1 Mounting Hole C2 Lock Nut Sealing Nut
APP® P/N (4 Characters) mm (in) mm (in) mm (in) mm (in) (mm) (mm)
PS1P16-10X PS01 11.2 - 5.5 (0.44 - 0.22) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 27
PS1P16-14X PS02 14.1 - 8.0 (0.56 - 0.31) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 27
Wire Protection Cable Range Thread O.D. Panel Thread Length Wrench Size Wrench Size
Designation Wire Outer Dia. C1 Mounting Hole C2 Lock Nut Sealing Nut
APP® P/N (4 Characters) mm (in) mm (in) mm (in) mm (in) (mm) (mm)
PR1P16-10X PR01 11.0 - 7.0 (0.43 - 0.28) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 12.0 (0.47) 30 27
PR1P16-13X PR02 13.0 - 8.0 (0.51 - 0.31) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 12.0 (0.47) 30 27
RIGHT ANGLE - STD PACK 50 / UL LISTED
Washer Body Seal Claw Sealing Nut
C2
C1
LOCK NUT FOR
PG 16 CABLE
GLANDS
Lock Nut
APP® Wrench Size Std. Pkg.
P/N Lock Nut (mm) Size
124G31 30 50
Washer Body Seal Sealing Nut
C1
C2
Wire Protection Cable Range Thread O.D. Panel Thread Length Wrench Size Wrench Size
Designation Wire Outer Dia. C1 Mounting Hole C2 Lock Nut Sealing Nut
APP® P/N (4 Characters) mm (in) mm (in) mm (in) mm (in) (mm) (mm)
PF1P16-10X PF01 11.2 - 5.5 (0.44 - 0.22) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PF1P16-13X PF02 13.8 - 8.0 (0.54 - 0.31) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
Notes:
1. For V0 material, contact the factory.
SPEC Pak® connectors are not UL recognized components when used with cable glands that are
not UL listed.
Torque Requirement
Cable Gland Body to Connector Shell
• Hand tighten until snug, tighten additional 1/8 to 1/4 turn with wrench
Sealing Nut to Cable
• Hand tighten until snug, tighten additional 1/2 to 3/4 turn with wrench
Gland Styles Straight Plastic
Straight Plastic With Flex Spring
Right Angle
Straight Plastic Multi-Hole
Straight Conduit Straight Conduit Push-In
Mechanical
IP Rating IP68 IP68
Operating Temperature
UL 1977 -40° to 105°C -31° to 100°C
-40° to 221°F -22° to 212°F
UL 6703A -35° to 65°C -
-31° to 149°F -
Thread Type PG PG
Thread Size 16 16
Flammability (UL 94) V2 1 -
Weatherability (UL 764C) F1 -
Material
Shell Nylon PA 66 Nylon PA 66
Gasket EPDM TPE
Color Black Black
www.andersonpower.com - 7 -
CORRUGATED NYLON PLASTIC TUBING
STRAIGHT CONDUIT ADAPTER THREAD TYPE - STD PACK 50 / NOT UL LISTED
STRAIGHT PLASTIC MULTI-HOLE TYPE - STD PACK 50 / NOT UL LISTED
C1
C2
Washer Body Seal Sealing Nut Corrugated
F1
STRAIGHT CONDUIT PUSH-IN TYPE - STD PACK 50 / NOT UL LISTED
Conduit I. D. Conduit O. D. Conduit Trade Std. Pkg.
APP® P/N mm (in) mm (in) Size Size (mm) Meters (Feet)
NGN - 12B 11.8 (0.46) 15.8 (0.62) 3/8” OD15.8 50 (164)
NGN - 14B 13.8 (0.54) 17.8 (0.70) - - 50 (164)
NGN - 17B 16.7 (0.66) 21.2 (0.83) 1/2” OD21.2 50 (164)
NGN - 23B 21.7 (0.85) 28.5 (1.12) 3/4” OD28.5 50 (164)
Wire Protection Thread O.D. Panel Thread Length Wrench Size Wrench Size APP® Conduit
Designation C1 Mounting Hole C2 Lock Nut Sealing Nut Conduit Trade
APP® P/N (4 Characters) mm (in) mm (in) mm (in) (mm) (mm) P/N Size
CAP16-15X CA01 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 21 NGN - 12B OD15.8
CAP16-18X CA02 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 21 - OD18.5
CAP16-21X CA03 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 10.0 (0.39) 30 27 NGN - 17B OD21.2
CAP16-28X CA04 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 12.0 (0.47) 30 34 NGN - 23B OD28.5
For R/A versions contact Factory
Wire Protection Cable Range Thread O.D. Panel Thread Length Wrench Size Wrench Size
Designation Number Wire Outer Dia. C1 Mounting Hole C2 Lock Nut Sealing Nut
APP® P/N (4 Characters) of Holes mm (in) mm (in) mm (in) mm (in) (mm) (mm)
PS2P16-3X PM21 2 3.5 - 2.5 (0.14 - 0.10) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS2P16-4X PM22 2 4.3 - 3.3 (0.17 - 0.13) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS2P16-6X PM23 2 6.1 - 4.3 (0.24 - 0.17) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS3P16-3X PM31 3 3.6 - 2.6 (0.14 - 0.10) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS3P16-5X PM32 3 5.2 - 3.5 (0.20 - 0.14) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS4P16-2X PM41 4 2.5 - 1.6 (0.10 - 0.06) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS4P16-3X PM42 4 3.6 - 2.5 (0.14 - 0.10) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS4P16-4X PM43 4 4.8 - 3.4 (0.19 - 0.13) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS5P16-2X PM51 5 2.1 - 1.3 (0.08 - 0.05) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS5P16-3X PM52 5 3.1 - 2.0 (0.12 - 0.08) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS5P16-4X PM53 5 4.1 - 3.0 (0.16 - 0.12) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS6P16-2X PM61 6 2.0 - 1.3 (0.08 - 0.05) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
PS6P16-3X PM62 6 3.0 - 2.0 (0.12 - 0.08) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 27
Wire Protection Max. Joint Thread O.D Panel Thread Length Wrench Size APP® Conduit
Designation F1 C1 Mounting Hole C2 Lock Nut Conduit Trade
APP® P/N (4 Characters) mm (in) mm (in) mm (in) mm (in) (mm) P/N Size
CT1P16-15X CT01 16.0 (0.63) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 NGN - 12B OD15.8
CT1P16-18X CT02 18.3 (0.72) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 NGN - 14B -
CT1P16-21X CT03 22.0 (0.87) 22.5 (0.89) 22.5 - 22.8 (0.89 - 0.90) 11.0 (0.43) 30 NGN - 17B OD21.2
Washer Body Seal
C1
C2
TUBING CUTTER
APP® P/N Description Range (mm)
TM0002 Corrugated Plastic Tubing Cutter Up to OD 34.5
C1
C2
Washer Body Seal Claw Sealing Nut
Standard Housing Arrangements & Contacts
www.andersonpower.com
- 8 -
HOUSING ARRANGEMENTS FOR POWER, SIGNAL & GROUND CONNECTORS
ARRANGEMENTS REPRESENT FRONT VIEW OF RECEPTACLE
Custom conguration may be created using APP’s part number congurator at www.andersonpower.com
1327G6FP
1827GA
1327G7FP
1327G6FP
4827G6
E
1327G6FP 1327FP
1827GA
AC Single Phase With 4 Signal
DC 2 Wire With 4 Signal
DC 2 Wire With Ground
& 4 Signal
DC 2 Wire
All Signal
L
J
N
1327G6FP E
1827GA
1327G7FP
1327G6FP 1327FP
1327G7FP 1827GA
1327G6FP 1327G6FP
1327FP 1327FP
1327G6FP E
1327FP 1827GA
Custom Configuration
AC Single Phase
AC 3 Phase, 3 Wire
DC 2 Circuit, 4 Wire
DC 2 Wire With Ground
A
0
C
B
D
E = Empty 1327 Series = Power 1827 Series = Ground 4800 Series = Signal
4827G6
1327FP
4827G6
4827G6
4827G6
4827G6
X
4827G6
DC 2 Wire With 8 Signal
4827G6
1327G6FP 1327FP
H
4827G6
1327G6FP
1327FP
E
U
E
Notes:
600 Volt Rating
• UL 1977 - All Configurations
• UL 6703A - Configuration B
• IEC 60664 - All Configurations
1000 Volt Rating
• IEC 60664 - Configuration U
www.andersonpower.com - 9 -
CONTINUOUS CURRENT RATINGS - POWER CONTACT CODE SELECTION
HOLDER LOCATIONS (VIEWS)
Front Back Front Back
Receptacle
Plug
2 1
4 3
1 2
3 4
1 2
3 4
2 1
4 3
NOTES:
1. Current ratings under UL1977:
• First number represents current rating per pole for 30°C temperature rise (25 / 38)
• Second number is the maximum recommended current per pole based on a 25°C ambient (25 / 38)
(Current ratings under UL 6703A, contact the factory)
2. Configuration H - N based on signal contacts crimped to #20 AWG wire and carrying 1 amp.
3. Denotes wire size not appropriate for power contact.
4. Shaded boxes are pending.
5. 1827GA housing should be used with 1830G1 or 1830G2 ground contact, depending on primary contacts.
All signal housings (4850) available with up to two 4802G3 and two 4803G3 contacts.
TEMPERATURE CHART
0
10
20
30
40
50
0 5 10 15 20 25 30 35 40
SPEC Pak® (4) Pole - Temperature Rise
Based on 261G2 Contact
Temperature (°C)
Amperes
#10 AWG
#12 AWG
#14 AWG
Individual components
www.andersonpower.com
- 10 -
POWERPOLE® HOUSINGS & CONTACTS
NOTE:
LD - Low Detent
15/45 Powerpole® Contacts
Loose Piece
Package Quantity:
Standard, 200 pieces - Bulk, 5,000 pieces
Standard Bulk
Part Number Part Number Description
#16 to #20 AWG (1.0 to 0.5 mm²)
1332 1332-BK Individual-LD-Silver Plate
262G1-LPBK - Singulated Reel-LD-Tin Plate
262G2-LPBK - Singulated Reel-LD-Silver Plate
#12 to #16 AWG (2.5 to 1.0 mm²)
1331 1331-BK Individual-LD-Silver Plate
261G1-LPBK - Singulated Reel-LD-Tin Plate
#10 to #14 AWG (4 to 1.5 mm²)
261G2-LPBK - Singulated Reel-LD-Tin Plate
261G3-LPBK - Singulated Reel-LD-Silver Plate
200G1L-LPBK - Superflex, Sing. Reel-LD-Tin Plate
Reel - 15/45 Powerpole® Contacts
Package Quantity 5,000
Part
Number Description
#16 to #20 AWG (1.0 to 0.5 mm²)
262G1 Reel-LD-Tin Plate
262G2 Reel-LD-Silver Plate
#12 to #16 AWG (2.5 to 1.0 mm²)
261G1 Reel-LD-Tin Plate
#10 to #14 AWG (4 to 1.5 mm²)
261G2 Reel-LD-Tin Plate
261G3 Reel-LD-Silver Plate
#10 to #14 AWG (6 to 1.5mm²)
200G1L SuperFlex, Reel-LD-Tin Plate
Fingerproof PP15/45 Housing Only
Package Quantity:
Standard, 200 pieces - Bulk, 2,500 pieces
Standard Bulk
Part Number Part Number Description
1327FP 1327FP-BK Red Housing
1327G5FP 1327G5FP-BK Green Housing
1327G6FP 1327G6FP-BK Black Housing
1327G7FP 1327G7FP-BK White Housing
1327G8FP 1327G8FP-BK Blue Housing
1327G16FP 1327G16FP-BK Yellow Housing
Standard PP 15/45 Housing Only
Package Quantity:
Standard, 200 pieces - Bulk, 2,500 pieces
Standard Bulk
Part Number Part Number Description
1327 1327-BK Red Housing
1327G5 1327G5-BK Green Housing
1327G6 1327G6-BK Black Housing
1327G7 1327G7-BK White Housing
1327G8 1327G8-BK Blue Housing
1327G16 1327G16-BK Yellow Housing
1327G17 1327G17-BK Orange Housing
1327G18 1327G18-BK Gray Housing
1327G21 1327G21-BK Brown Housing
1327G22 1327G22-BK Pink Housing
1327G23 1327G23-BK Purple Housing
Premate Ground PP15/45 Housing Only
Package Quantity:
Standard, 200 pieces - Bulk, 2,500 pieces
Standard Bulk
Part Number Part Number Description
1827GA 1827GA-BK Green Housing
Premate Ground Contacts
Loose Piece
Package Quantity 200
Part
Number Description
#10 to #14 AWG (4 to 1.5 mm²)
1830G1-LPBK Singulated-LD-Tin Plate
1830G2-LPBK Singulated-LD-Silver Plate
Reel
Package Quantity 5,000
Part
Number Description
#10 to #14 AWG (4 to 1.5 mm²)
1830G1 Reel-LD-Tin Plate
1830G2 Reel-LD-Silver Plate
Individual Singulated Open Barrel On a Reel
CONTACT STYLES
www.andersonpower.com - 11 -
PPMX (4800 SERIES) HOUSING & CONTACTS PP15/45 POWERPOLE®
HOUSING STYLES
* All Hand and Pneumatic Tools for use with Loose Piece contacts only. All reeled contacts can be ordered singulated, (Loose Piece) with the suffix “- LPBK”
** 1309G8 is a hand tool kit- includes dies and locators to make up 1309G2, 1309G3, &1309G6
APPLICATION TOOLING - POWERPOLE® 15 / 45 CONTACTS
Powerpole®
Fingerproof Housing
Rib Feature
Powerpole®
Standard Housing
Closed Nose
Powerpole®
Premate Ground Housing
Open Nose
PPMX Housing
2 Socket & 2 Pin Contacts
Open Nose
1327FP Series
1327 Series
1827 Series
4800 Series
Loose Piece Tin
Part Number
Loose Piece
Silver Part
Number Hand Tool* or Pneumatic Tool*
Reeled Tin Part
Number
Reeled Silver
Part Number ATS Applicator
N/A 1332 N/A N/A N/A
N/A 1331 N/A N/A N/A
262G1-LPBK 262G2-LPBK 261G1 262G2 1385520
200G2L-LPBK 200G4L-LPBK 200G2L 200G4L TBD
261G1-LPBK 261G4-LPBK 261G1 261G4 1385520
261G2-LPBK 261G3-LPBK 261G2 261G3 1385458
200G1L-LPBK 200G3L-LPBK 200G1L 200G3L 1385460
1830G1-LPBK 1830G2-LPBK 1830G1 1830G2 1385460
1367G1
N/A
1309G3 or
1309G8**
1309G6 or
1309G8**
1309G2 or
1309G8**
Contact
Part Number APP® Hand Tool or
Mil Std.Hand
Tool
(APP Part #) + Positioner +
Pneumatic Tool
for Locator /
Turret
4802G3
4803G3
No Mil Std.
(TL0005) TP0001PM1000G1 M22520/1-01
(TM0001)
APPLICATION TOOLING - PPMX CONTACTS
PPMX Signal Housing
Package Quantity
Standard, 25 pieces - Bulk, 1,000 pieces
Standard Bulk
Part Number Part Number Description
4827G6 4827G6-BK Black two piece housing
PPMX Signal Contacts
Package Quantity
Standard, 50 pieces - Bulk, 2,000 pieces
Loose Piece
#20 to #24 AWG (0.50 to 0.25 mm²)
Standard Bulk
Part Number Part Number Description
4802G3 4802G3-BK Socket, Gold, 50 Micro-inches
4803G3 4803G3-BK Pin, Gold, 50 Micro-inches
PPMX Signal Housing & Contact Kits
Package Quantity
Standard, 100 pieces
1 Black two piece housing, 2 Male Contacts,
2 Female Contacts
Standard Bulk
Part Number Part Number Description
4850G6 - 50 Micro-inches Gold Plated Contacts - Pin & Socket
www.andersonpower.com
- 12 -
Dimensions
All Data Subject To Change Without Notice Patents with Patents Pending 15145 DS-SOLARSPAK REV 02
HEADQUARTERS: Anderson Power Products®, 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T:978-422-3600 F:978-422-0128
EUROPE: Anderson Power Products® Ltd., Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, Cheshire, WA5 7TN United Kingdom T: +44 (0) 1925 428390 F: +44 (0) 1925 520203
ASIA / PACIFIC: IDEAL Anderson Asia Pacic Ltd., Unit 922-928 Topsail Plaza, 11 On Sum Street, Shatin N.T., Hong Kong T:+(852) 2636 0836 F:+(852) 2635 9036
CHINA: IDEAL Anderson Technologies (Shenzhen) Ltd., Block A8 Tantou Western Industrial Park, Songgang Baoan District, Shenzhen, PR. China 518105 T: +(86) 755 2768 2118 F: +(86) 755 2768 2218
TAIWAN: IDEAL Anderson Asia Pacic Ltd., Taiwan Branch, 4F.-2, No.116, Dadun 20th St., Situn District, Taichung City 407, Taiwan (R.O.C.) T: +(886) 4 2310 6451 F:+(886) 4 2310 6460
www.andersonpower.com
[ 53.6 ]
2.11
[ 68.3 ]
2.69
PG 16
FEMALE
THREAD [ 40.4 ]
1.59
INTERFACIAL
GASKET
[ 33.7 ]
1.33
[ 68.3 ]
2.69
[ 68.6 ]
2.70
[ 35.4 ]
R1.36 SWEEP
OF LATCH
[ 123.6 ]
4.87
[ 38.7 ]
1.52
[ 29.4 ]
1.16
Top View Front View Side View Mated Side View
Panel Cut Out Front View Side View Back View
Top View Front View Side View Mated Side View
PS - Plastic CT - Threaded Conduit CA - Push-in Conduit PF - Plastic PR - Right Angle
Short Adapter Adapter Flex PG
Front View Side View Front View Side View
PLUG 4 POSITION FOR PP15/45 HOUSINGS
PANEL MOUNT RECEPTACLE 4 POSITION FOR PP15/45 HOUSINGS
INLINE RECEPTACLE 4 POSITION FOR PP15/45 HOUSINGS
PG GLANDS
RECEPTACLE COVER KIT PLUG COVER KIT
[ 50.2 ]
1.98
[ 38.2 ]
1.50
[ 38.4 ]
1.51
[ 33.7 ]
1.33
[ 54.1 ]
2.13
[ 23.2 ]
0.91
[ 95.1 ]
3.74
[ 43.9 ]
1.73
[ 33.0 ]
1.30
[ 33.0 ]
1.30
[ 50.2 ]
1.98
[ 44.5 ]
1.75
[ 44.5 ]
1.75
[ 55.6 ]
2.19
[ 44.5 ]
1.75
[ 50.3 ]
1.98