MODEL NUMBERS AC CONTROL A1210 A1225 A1240 A2410 A2425 A2450 A2475 A2490
DC CONTROL D1210 D1225 D1240 D2410 D2425 D2450 D2475 D2490
OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vrms] 24-140 24-140 24-140 24-280 24-280 24-280 24-280 24-280
Max. Load Current 3[Arms] 10 25 40 10 25 50 75 90
Min. Load Current, [mArms] 40 40 40 40 40 40 40 40
Transient Overvoltage [Vpk] 400 400 400 600 600 600 600 600
Max. Surge Current, (16.6ms) [Apk] 120 250 625 120 250 625 1000 1200
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Thermal Resistance Junction to Case (RθJC) [°C/W] 1.48 1.02 0.63 1.48 1.02 0.63 0.31 0.28
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 60 260 1620 60 260 1620 4150 6000
Max. Off-State Leakage Current @ Rated Voltage [mArms] 88 81010101010
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] 2500 500 500 500 500 500 500 500
Max. Turn-On Time 41/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time 1/2 Cycle (DC Control), 40.0 msec(AC Control)
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS 1DC CONTROL AC CONTROL 24V AC/DC CONTROL
(E SUFFIX)
Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms/Vdc
Max. Reverse Voltage -32 Vdc --- ---
Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms/Vdc
Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms/Vdc
Nominal Input Impedance 1500 Ohms 60K Ohms 9.0K Ohms
Typical Input Current 3.4mA @ 5 Vdc, 20mA @ 28Vdc 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 V
GENERAL NOTES
1All parameters at 25° C unless otherwise specified.
2Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3Heat sinking required, for derating curves see page 3.
4Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
Zero Voltage and Random
Turn-On Switching
Panel Mount
600V Transient Capability
Internal Snubber
110 & 125A Models
Available
SERIES1
Rev. 082305
PAGE 1 OF 3
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross, random turn-
on (phase controllable) and normally
closed (Form B) versions with either
AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
© 2005 CRYDOM CORP, Specifications subject to change without notice.
Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1
10-90Amp • 120/240 Vac - AC OUTPUT
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
SERIES1
Rev. 082305
PAGE 2 OF 3
AVAILABLE OPTIONS
-B Normally Closed (Form B)
Example: D2450-B, A2450-B
4D 400 Hz Operation
10-50 Amp Models Only
Zero Cross Switching Only
Example: 4D2450
E24V AC/DC Input
Example: A2450E
-10 Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D2450-10
FFaston Terminals (Up to 50A Models)
Example: D1225F
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc 10 9Ohm
Max. Capacitance Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical) 3.0 oz. (86.5g)
Encapsulation: Thermally Conductive Epoxy
Terminals: Screws and Saddle Clamps Furnished, Unmounted
APPROVALS
UL E116949
CSA LR81689
VDE 10143 UG
(Not Applicable: -B and 4D)
Crydom Heat Sinks offer excellent
thermal management and are per-
fectly matched to the load current rat-
ings of Crydom panel mount relays.
Request Crydom’s Heat Sink specifica-
tion sheet for all the details.
© 2005 CRYDOM CORP, Specifications subject to change without notice.
All dimensions are in inches (millimeters)
.90
(22.9)
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
BASE PLATE
.125 (3.2)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.87 REF.
(22.2)
OUTPUT
INPUT
1.00
(25.4)
1.80
(45.7)
.45
(11.4)
1.10
(27.9)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
PInternal Overvoltage Protection.
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads.
Not Available with -B Option
Agencies Approval Pending.
Example: D2425P
GInput Status LED.
Agencies Approval Pending
Example: D2450G
Note: Control Voltage Range 4.5-32Vdc
for DC Control Models.
1 2
43
+
--
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.90
(22.9)
.45
(11.4)
1.10
(27.9)
8-32 TERMINAL
(2 PLACES )
1.00
(25.4) 6-32 TERMINAL
(2 PLACES)
1.80
(45.7)
12
OUTPUT
34 +--
INPUT
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
BASE PLATE
.125 (3.2)
Ordering System: Combination of the
suffixes should be made in the following order:
EFPG-10.
Example: A2450EFPG-10
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
H Heat Transfer Pad (Attached)
Example: D2450H
Series 1
10-90Amp • 120/240 Vac - AC OUTPUT
12
8
4
0
24 8106 20406080
Load Current [Arms] Max Ambient Temp. [°C]
Power Dissipation
110
115
120
Base Plate Temp [°C]
10A
9°C/W 5°C/W
3°C/W
7°C/W
NO HEATSINK
30
20
10
25
15
5
0
510 202515 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
Power Dissipation
95
120
Base Plate Temp [°C]
25A
1°C/W
100
110
3°C/W
NO HEATSINK
60
40
20
0
10 20 40 5030 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
Power Dissipation
90
Base Plate Temp [°C]
50A
2°C/W
1°C/W .5°C/W
100
110
120
1.5°C/W
NO HEATSINK
120
80
40
0
15 30 60 7545 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
Power Dissipation
100
110
120
Base Plate Temp [°C]
75A
.5°C/W
95
1°C/W
120
80
40
0
20 40 80 060 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
Power Dissipation
100
110
120
Base Plate Temp [°C]
90A
1°C/W
.4°C/W
.2°C/W
90
.5°C/W
2°C/W
.3°C/W
CURRENT DERATING CURVES
SERIES1
Rev. 082305
PAGE 3 OF 3
© 2005 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1
10-90Amp • 120/240 Vac - AC OUTPUT