Low Temperature Passive Probes LTP Series 32309592 Issue E Datasheet Bosch Kompact AMP Minitimer Delphi Metri-Pack 150 Series AMP Superseal 1.5 Series 2P AMP Seal 16 Deutsch DT04-2P DESCRIPTION Honeywell's Low Temperature Passive Probes, LTP Series, are a modular range of temperature sensors designed for potential use in transportation applications. The LTP Series feature a durable, closed-tip design that maximizes reliability in harsh applications. The sensor's thermistor sensing element effectively senses liquids and gases because of its enhanced sensitivity, accuracy and reliability. Easy-to-install threaded mounting provides reliable operation in harsh environments. Numerous options--from mechanical and electrical interface-- simplify installation, allow customers to meet their specific application needs, and facilitate backwards-compatibility with most existing applications. VALUE TO CUSTOMERS The LTP Series are designed to meet the customer's need for sensors that are configurable, backwards-compatible, durable, and that reduce total cost of ownership. Their flexible design provides over 2,200 standard configurations with an enhanced response time over a wide operating temperature range. DIFFERENTIATION * Seven probe lengths, four NTC thermistor sensor curves, 12 thread options ranging from M10 to M18, 3/4 UNF, and G 1/4, and two hex options * Zero NRE (non-recurring engineering) costs for configurations * Reduces cost of ownership due to BOM (bill of materials), engineering, testing, NRE and tooling * Reduces design costs due to plug-and-play options, backwards integration, flexible offering, customization and non-standard offering Sensing and Productivity Solutions FEATURES * Temperature range: -40 C to 150 C [-40 F to 302 F] * Response time [T63.2% of 25 C to 85 C step]: stirred silicon oil <15 s; stirred water <15 s; air flow 10 m/s <20 s * Accuracy: - -40 C to 25 C [-40 F to 77 F]: 2.5 C - 25 C to 100 C [77 F to 212 F]: 0.8 C - 100 C to 125 C [212 F to 257 F]: 2.0 C - 125 C to 150 C [257 F to 302 F]: 3.5 C * Electrical interface: Bosch Kompakt, Delphi Metri-Pack 150 Series, AMP Seal 16, AMP Minitimer, AMP Superseal 1.5 Series 2P, and Deutsch DT04-2P * Probe length options: 20 mm to 50 mm (other lengths available upon request) * Mechanical fastening options: M10 to M18, 3/4 UNF, and G 1/4 (other threads available on request) * Retainer ring with hex: provides complete location for socket wrench in axial and radial directions, enabling the operator to first locate the sensor inside the socket to freely and more easily install the sensor * Insulation resistance between I/O pin and the sensor's housing: >10 MOhm at 250 Vdc, 25 C [77 F] * Ingress protection: IP67 * Vibration: 30 g sine wave,10 Hz to 2000 Hz * Mechanical shock: 50 g * Service pressure: 10 bar * Burst pressure: 40 bar * Wire harness (with or without a connector) or other sensing elements (PTC or RTD) available upon request POTENTIAL TRANSPORTATION APPLICATIONS * Ambient air temperature sensor * Automatic transmission system * Engine air inlet system * Engine cooling system * Engine lubrication system * Fuel system * Haldex coupling system * Hydraulic pump systems PORTFOLIO The LTP Series joins the R300, 500, ES110, ES120, and 6655 Series that offer a variety of housing materials and styles, terminations and R-T curves, depending on the customers' application needs. Low Temperature Passive Probes, LTP Series Table 1. Operating and Environmental Specifications Characteristic Condition PParameter Sensing element -- NTC thermistor Sensed media capability -- engine coolant, engine oil, fuel, air, hydraulic oil, water Response time (T63.2%) -- Current -- 10 mA max. (self heating) Insulation resistance -- >10 MOhm at 250 Vdc, 25 C [77 F] Accuracy -- 0.8 C, 25 C to 100 C ( See Table 3.) Operating temperature range * * * less than 15 s in stirred silicon oil temperature step 25 C to 85 C [77 F to 185 F] continuous 500 hr at 150 C 500 thermal shocks from -40 C to 150 C 100 thermal cycles from -40 C to 150 C -40 C to 150 C [-40 F to 302 F] Storage temperature range -- -40 C to 150 C [-40 F to 302 F] Vibration -- 30 g sine, 10 Hz to 2000 Hz Operating pressure -- 10 bar max. Burst pressure -- 40 bar max. Compliance -- RoHS, REACH Table 2. Mechanical Specifications Characteristic Parameter Storage temperature range -40 C to 150 C [-40 F to 302 F] Probe tip static side load Electrical connector type: Bosch Kompakt 1.1a Series (2-way, 1928404226) Delphi Metri-Pack 150 Series (12191170) AMP Seal 16 (767428-1) AMP Minitimer (2 Position, 106462-1) AMP Superseal 1.5 Series 2P (282104-1) Deutsch DT04-2P (2 position) Mechanical connector thread size: M10 X 1,25 M12 X 1,5 M14 X 1,5 M16 X 1,5 M18 X 1,5 3/4-16-2A UNF (SAE 8) G 1/4 2 Sensing and Productivity Solutions 80 N Material tin-plated brass tin-plated brass gold-plated brass tin-plated brass tin-plated brass gold-plated brass Standard ISO 261 ISO 261 ISO 261 ISO 261 ISO 261 ISO J1926-3 ISO 228-2 IP Rating IP67, IP69K IP67 IP67 IP64 IP67 IP67 Mating Connector Bosch Kompakt (1928403874) Delphi Metri-Pack (12162193) AMP Seal 16 (776427-1) Junior Power Timer (282189-1) AMP Superseal (282080-1) Deutsch DT06-2S Torque 8 1 N m 15 1 N m 15 1 N m 20 1 N m 20 1 N m 20 1 N m 15 1 N m Low Temperature Passive Probes, LTP Series Table 3. Resistance vs Temperature Curve and Sensor Accuracy Resistance (Ohm) Temperature (C) Minimum Nominal Maximum Temperature Tolerance (C) -40 28141.68 33487.40 38833.11 2.5 NTC-1000 at 25 C 25 964.88 1000.0 1035.12 0.8 (3947 Beta 0 C/100 C) 100 67.63 69.24 70.86 0.8 150 17.75 19.31 20.87 3.5 -40 41061.23 48032,75 55004.26 2.5 NTC-2057 at 25 C 25 1993.09 2057.00 2120.91 0.8 (3520 Beta 0 C/100 C) 100 183.7 187.53 191.37 0.8 150 52.59 56.57 60.55 3.5 -40 63419.83 75491.04 87562.26 2.5 NTC-2252 at 25 C 25 2172.92 2252.00 2331.08 0.8 (3947 Beta 0 C/100 C) 100 149.32 152.90 156.47 0.8 150 36.89 41.70 46.51 3.5 -40 85718.02 102530.35 119342.68 2.5 NTC-2795 at 25 C 25 2694.40 2795.00 2895.6 0.8 (4073 Beta 0 C/100 C) 100 173.36 177.62 181.88 0.8 150 43.07 46.95 50.83 3.5 Thermistor Curve Figure 1. Schematic Up = 5 V Rp Sensor Typical voltages: Power supply: Up = +5 +0.1 Vdc (Depends on application system.) Typical resistance: Pull-up: Rp = precision resistor (+0.1% typical) Notes: 1. Maximum current through the circuit: 10 mA 2. Self heating error needs to be considered and is addtional to sensor basic accuracy Sensing and Productivity Solutions 3 Low Temperature Passive Probes LTP Series Low Temperature Passive Probes, LTP Series Product Nomenclature Figure 2. Nomenclature and Order Guide1 For example, LTPCTAA20MBSITX01 defines an LTP Series Low Temperature Passive Probe, -40 C to 150 C [-40 F to 302 F] temperature range, configurable construction type, NTC Thermistor outptut, NTC-1000 at 25 C (3947 Beta 0 C/100 C) thermistor curve, 0.8 C, 25 C to 100 C accuracy, 20 mm probe tip length, M10 X 1,25 mechanical connector thread size, 19 mm mechanical connector hex size, integral connector electrical interface, Deutsch DT04-2P electrical connector type. L TP C T A A 20 MB S I T X 01 Designation1 Temperature Range L 01 Pigtail Length Temperature Probe X TP Construction Type C B D E M S T Thermistor, NTC Thermistor Curve A F G H NTC-1000 at 25 C (3947 Beta 0 C/100 C) Bosch Kompact 1.1a Series (2-way, 1928404226) Delphi Metri-Pack 150 Series (12191170) Amp Seal 16 (767428-1) AMP Minitimer (2 position, 106462-1) AMP Superseal 1.5 Series 2P (282104-1) Deutsch DT04-2P (2 position) NTC-2057 at 25 C (3520 Beta 0 C/100 C) Electrical Interface NTC-2252 at 25 C (3947 Beta 0 C/100 C) I NTC-2795 at 25 C (4073 Beta 0 C/100 C) Accuracy A 20 25 30 35 40 45 50 Integral connector Mechanical Connector Hex Size 0.8 C, 25 C to 100 C S B Probe Tip Length 20 1,0 mm 19 mm A/F 22 mm A/F Mechanical Connector Thread Size2 25 1,0 mm 30 1,0 mm 35 1,0 mm 40 1,0 mm 45 1,0 mm 50 1,0 mm Notes: 1 Standard configurations shown, customization available upon request. 2 MI and UE Mechanical Connectors available only with Mechanical Connector Hex Size B (22 mm A/F). Probe Mechanical connector thread size Mechanical Connector Probe tip length Hex size Electrical Interface/Electrical Connector Type 9,5 mm [0.37 in] 4,0 mm [0.16 in] 009092-5-EN IL50 March 2016 Copyright (c) 2016 Honeywell International Inc. All Rights Reserved. 4 Integral connector Electrical Connector Type Configurable Output T Standard -40 C to 150 C [-40 F to 302 F] Sensing and Productivity Solutions 36 mm [1.42 in] MB MD MF MH MI2 UE2 GB M10 X 1,25 M12 X 1,5 M14 X 1,5 M16 X 1,5 M18 X 1,5 3/4 -16 UNF (SAE 8) G 1/4 Low Temperature Passive Probes, LTP Series Figure 3. 19 mm Hex Mechanical Connector and Corresponding Installation Port Dimensions (For reference only: mm.) 19 mm Hex Mechanical Connector 19,0 0,5 Thread G (mm) W (mm) M10 X 1,25 8,4 0,2 2,0 0,2 M12 X 1,5 9,7 0,2 3,0 0,2 M14 X 1,5 11,7 0,2 3,0 0,2 Corresponding Installation Port Per BS-ISO-6149-1:2006 for metric threads Per J1926-1 for UNF threads oD1 oD2 R 0,1 to 0,2 R 0,40 Max. L1 0.2 A 0.1 L3 W G 17,0 0,3 L3 L2 Z 45 5 o6,00 Thread M16 X 1,5 G (mm) W (mm) 13,7 0,2 3,0 0,3 19,0 0,5 W G Thread D1 (mm) Thread A Datum at pitch diameter D2 (mm) L1 L2 L3 L4 Z (mm) (mm) (mm) (mm) (mm) M10 X 1,25 20 11,1 (+0,1, -0) 1,6 11,5 1,5 10 12 M12 X 1,5 23 13,8 (+0,1, -0) 2,4 14 1,5 11,5 15 M14 X 1,5 25 15,8 (+0,1, -0) 2,4 14 1,5 11,5 15 M16 X 1,5 28 17,8 (+0,1, -0) 2,4 15,5 1,5 13 15 M18 X 1,5 30 19,8 (+0,1, -0) 2,4 17 2,0 14,5 15 3/4-16-2A UNF (SAE 8) 30 20,6 (+0,13, -0) 2,5 17,5 2,5 14,3 15 21,5 0,3 Thread G (mm) W (mm) G 1/4 11,2 0,2 3,2 0,3 Per BS-ISO-1179-1:2013 D3 D4 90.00 0.1 B L5 19,0 0,5 L7 L6 W G o6,00 17,0 0,3 Thread Thread D3 (mm) D4 (mm) G 1/4 20 13,2 (+0,2, -0) B Datum and pitch diameter L5 L6 (mm) (mm) 1,5 12,5 L7 (mm) 15,5 Sensing and Productivity Solutions 5 Low Temperature Passive Probes, LTP Series Figure 4. 22 mm Hex Mechanical Connector and Corresponding Installation Port Dimensions (For reference only: mm.) 22 mm Hex Mechanical Connector 22,0 0,5 W G Corresponding Installation Port Thread G (mm) W (mm) M10 X 1,25 8,4 0,2 2,0 0,2 M12 X 1,5 9,7 0,2 3,0 0,2 M14 X 1,5 11,7 0,2 3,0 0,2 Per BS-ISO-6149-1:2006 for metric threads Per J1926-1 for UNF threads 17,0 0,3 oD1 oD2 R 0,1 to 0,2 R 0,40 Max. L1 22,0 0,5 Thread G (mm) L2 W (mm) M16 X 1,5 13,7 0,2 3,0 0,2 M18 X 1,5 15,7 0,2 3,0 0,2 L3 0.2 A 0.1 L3 Z 45 5 o6,00 Thread A Datum at pitch diameter W G 25,0 0,3 22,0 0,5 Thread G (mm) W (mm) 3/4-16-2A UNF 16,76 0,1 2,4 0,3 (SAE 8) Thread D1 (mm) D2 (mm) L1 L2 L3 L4 Z (mm) (mm) (mm) (mm) (mm) M10 X 1,25 20 11,1 (+0,1, -0) 1,6 11,5 1,5 10 12 M12 X 1,5 23 13,8 (+0,1, -0) 2,4 14 1,5 11,5 15 M14 X 1,5 25 15,8 (+0,1, -0) 2,4 14 1,5 11,5 15 M16 X 1,5 28 17,8 (+0,1, -0) 2,4 15,5 1,5 13 15 M18 X 1,5 30 19,8 (+0,1, -0) 2,4 17 2,0 14,5 15 3/4-16-2A UNF (SAE 8) 30 20,6 (+0,13, -0) 2,5 17,5 2,5 14,3 15 W G 25,0 0,3 22,0 0,5 Thread G (mm) W (mm) G 1/4 11,2 0,2 3,2 0,3 Per BS-ISO-1179-1:2013 L7 D3 D4 90.00 0.1 B L5 L6 W G o17,0 0,3 o6,00 6 Sensing and Productivity Solutions Thread B Datum and pitch diameter Thread D3 (mm) D4 (mm) L5 (mm) L6 (mm) L7 (mm) G 1/4 20 13,2 (+0,2, -0) 1,5 12,5 15,5 Low Temperature Passive Probes, LTP Series Figure 5. Electrical Connector Type Dimensions (For reference only: mm.) B: Bosch Kompact D: Delphi Metri-Pack 150 Series E: Amp Seal 16 M: Amp Minitimer S: Amp Super Seal 1.5 Series T: Deutsch DT04-2P 39 2 32 2 35 2 28 2 35,70 2 36 2 Sensing and Productivity Solutions 7 ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: * Product Range Guide * Product Line Guide * Product Installation Instructions * Technical Information: Detailed resistance vs temperature curves WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * * The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell Sensing Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. and Productivity Solutions' products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Productivity Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 32309592-E-EN IL50 March 2016 (c) 2016 Honeywell International Inc. All rights reserved.