© 2000 IXYS All rights reserved 1 - 3
Symbol Test Conditions Maximum Ratings
IRMS TC = 110°C, 50 - 400 Hz, module 54 A
ITRMS TVJ = TVJM 39 A
ITAVM TC = 110°C; (180° sine) 25 A
ITSM TVJ = 45°C; t = 10 ms (50 Hz), sine 400 A
VR = 0 t = 8.3 ms (60 Hz), sine 430 A
TVJ = TVJM t = 10 ms (50 Hz), sine 350 A
VR = 0 t = 8.3 ms (60 Hz), sine 370 A
I2tTVJ = 45°C t = 10 ms (50 Hz), sine 800 A2s
VR = 0 t = 8.3 ms (60 Hz), sine 780 A2s
TVJ = TVJM t = 10 ms (50 Hz), sine 610 A2s
VR = 0 t = 8.3 ms (60 Hz), sine 570 A2s
(di/dt)cr TVJ = TVJM repetitive, IT = 150 A 100 A/ms
f =50 Hz, tP =200 ms
VD = 2/3 VDRM
IG = 0.3 A non repetitive, I T = ITAVM 500 A/ms
diG/dt = 0.3 A/ms
(dv/dt)cr TVJ = TVJM;V
DR = 2/3 VDRM 1000 V/ms
RGK = ¥; method 1 (linear voltage rise)
PGM TVJ = TVJM tp = 30 ms10W
IT = ITAVM tp = 300 ms5W
PGAVM 0.5 W
VRGM 10 V
TVJ -40...+150 °C
TVJM 150 °C
Tstg -40...+150 °C
VISOL 50/60 Hz, RMS 2500 V~
IISOL £ 1 mA
MdMounting torque (M4) 1.1 - 1.5 / 9 - 13 Nm/lb.in.
Terminal connection torque (M4) 1.1 - 1.5 / 9 - 13 Nm/lb.in.
Weight typ. 30 g
VRSM VRRM Type
VDSM VDRM
VV
1200 1200 MMO 62-12io6
1600 1600 MMO 62-16io6
Features
●Thyristor controller for AC (circuit
W1C acc. to IEC) for mains frequency
●International standard package
miniBLOC (ISOTOP compatible)
●Isolation voltage 2500 V~
●Planar passivated chips
●UL registered, E 72873
Applications
●Switching and control of single and
three phase AC
●Softstart AC motor controller
●Solid state switches
●Light and temperature control
Advantages
●Easy to mount with two screws
●Space and weight savings
●Improved temperature and power
cycling
●High power density
008
MMO 62
Data according to IEC 60747 and to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions.
IRMS = 54 A
VRRM = 1200-1600 V
AC Controller Modules
miniBLOC, SOT-227 B
K2/A1
G1
K1/A2 G2
K2/A1 G2
G1 K1/A2
http://store.iiic.cc/