1
Connector Termination Switch D3M
Saves Wiring Effort, Production Steps,
and Time
Easy wiring ensured through the quick-connect
terminals.
External
actuator mounts in either
of two directions
and increases Switch mounting flexibility.
Horizontal layout of terminals saves mounting
space.
Same mounting pitch as the OMRON SS
Subminiature
Basic Switch.
RCE
Ordering Information
Model Number Legend
D3M-01jjj
123
1. Actuator
Mounting Position
None:
No actuator
K:
Pushbutton close to actuator fulcrum
L:
Pushbutton far from actuator fulcrum
2. Actuator
None:
Pin plunger
1:
Hinge lever
2:
Hinge roller lever
3:
Simulated hinge lever
3. Contact Form
None: SPST
-NC (with red pushbutton)
-3: SPST
-NO (with black pushbutton)
Note:
For details about models with a low operating force, contact your OMRON sales representative.
D3M D3M
2
List of Models
Actuator Actuator
mounting position
Contact type
Model
Pin plunger
--- SPST-NC D3M-01
pu ge
SPST-NO D3M-01-3
Hinge lever
KSPST-NC D3M-01K1
geee
SPST-NO D3M-01K1-3
LSPST-NC D3M-01L1
SPST-NO D3M-01L1-3
Hinge roller lever
KSPST-NC D3M-01K2
g
SPST-NO D3M-01K2-3
LSPST-NC D3M-01L2
SPST-NO D3M-01L2-3
Simulated hinge lever
KSPST-NC D3M-01K3
S uaed geee
SPST-NO D3M-01K3-3
LSPST-NC D3M-01L3
SPST-NO D3M-01L3-3
Specifications
Ratings
Rated
voltage Resistive load
30 VDC
0.1 A
Use the D3M in the following permissible operating range.
Operating
range
Inoper-
able
range
Voltage (V)
Current
(mA)
Minimum
Applicable Load (Level N)
Voltage
Resistive load
5 VDC
1 mA
Refer to
Minute Load
on page
18 for details.
D3M D3M
3
Characteristics
Permissible
operating speed (see note 1) 0.1 mm/s to 1 m/s
Permissible operating frequency
Mechanical: 400 operations/min max.
e ss b e ope a g eque cy
Electrical: 60 operations/min max.
Insulation resistance
100 M
min. at 500 VDC
Contact resistance (initial value)
100 m
max. including connector and 50-mm A
WG28 lead-wire resistance
Dielectric strength
1,000 V
AC at 50/60 Hz for 1 min between terminals of the same polarity
eec cs e g
1,500 V
AC at 50/60 Hz for 1 min between charged metal part and ground
1,500 V
AC at 50/60 Hz for 1 min between non-charged metal part and each
terminal
V
ibration resistance (see note 2)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 1 ms max. with contacts
closed or open.
Shock resistance (see note 2)
Destruction: 1,000 m/s
2
{approx. 100G} max.
S oc es s a ce (see o e )
Malfunction: 300 m/s
2
{approx. 30G} for 1 ms max. with contacts closed or open.
Life expectancy
Mechanical:
500,000 operations (at full-stroke operating speed of 10 mm/s at a
frequency of 60 operations/min)
Electrical: 200,000 operations (at full-stroke operating speed of 10 mm/s at a
frequency of 30 operations/min)
Enclosure rating
IP00
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Ambient temperature
Operating: –25
°
C to 85
°
C (with no icing)
Ambient humidity
Operating: 85% max. (5
°
C to 35
°C)
Weight
Approx. 2 g (pin plunger models)
Note: 1.
The permissible operating speed applies to pin plunger models.
2.
If a lever actuator model is used, the above values apply for use at the total travel position.
Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No. 55 (File No. LR21642)
TÜV EN61058-1 (File No. R9750979)
Rated
voltage
Rated current
30 VDC
0.1 A
Contact Specifications
Contact Crossbar
Material Gold
alloy
Distance between contacts
0.5 mm
Contact Form
SPST-NC
NC
COM
SPST-NO
NO
COM
D3M D3M
4
Dimensions
Note: 1. All
units are in millimeters unless otherwise indicated.
2.
Unless otherwise specified, a tolerance of
±
0.4 mm applies to all dimensions.
Dimensions and Operating Characteristics
Pin Plunger
OF
max.
1.50 N {153 gf}
RF min.
0.25 N {25 gf}
PT max.
0.6 mm
OT min.
0.4 mm
MD max.
0.1 mm
OP 8.4±
0.3 mm
Hinge Lever
OF
max.
0.50 N {51 gf}
RF min.
0.06 N {6 gf}
OT min.
1.2 mm
MD max.
0.8 mm
FP max.
14.0 mm
OP 10.0±
0.8 mm
OF max.
1.00 N {102 gf}
RF min.
0.10 N {10 gf}
OT min.
0.7 mm
MD max.
0.6 mm
FP max.
1
1.5 mm
OP 9.2±
0.6 mm
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The
Dipole XA Connector consists of
the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
(See note 2)
(See note 1)
(See note 2)
2.5 dia.
2.35 dia.
+0.1
–0.05
D3M-01
D3M-01-3
OP FP
Stainless steel (t = 0.3)
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The
Dipole XA Connector
consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
2.5 dia.
(See note 2)
(See note 2)
(See note 1)
2.35 dia.
+0.1
–0.05
D3M-01K1
D3M-01K1-3
OP FP
Stainless steel (t = 0.3)
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The Dipole XA Connector consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
2.5 dia.
(See note 1)
(See note 2)
2.35 dia.
+0.1
–0.05
(See note 2)
D3M-01L1
D3M-01L1-3
OP FP
D3M D3M
5
Hinge Roller Lever
OF
max.
0.50 N {51 gf}
RF min.
0.06 N {6 gf}
OT min.
1.2 mm
MD max.
0.8 mm
FP max.
19.7 mm
OP 15.7±
0.8 mm
OF max.
1.00 N {102 gf}
RF min.
0.10 N {10 gf}
OT min.
0.7 mm
MD max.
0.6 mm
FP max.
17.2 mm
OP 14.9±
0.6 mm
Simulated Hinge Lever
OF
max.
0.50 N {51 gf}
RF min.
0.06 N {6 gf}
OT min.
1.2 mm
MD max.
0.8 mm
FP max.
16.2 mm
OP 12.2±
0.8 mm
4.8
dia. x 3.2
polyacetal
resin roller
Stainless steel (t = 0.3)
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The Dipole XA Connector consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
2.5 dia.
(See note 2)
(See note 2)
(See note 1)
OP FP
2.35 dia.
+0.1
–0.05
D3M-01K2
D3M-01K2-3
4.8 dia. x 3.2 polyacetal resin roller
Stainless steel (t = 0.3)
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The
Dipole XA Connector consists of the following
components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
2.5 dia.
(See note 2)
(See note 2)
(See note 1)
2.35 dia.
+0.1
–0.05
D3M-01L2
D3M-01L2-3
OP FP
Stainless steel (t = 0.3)
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The Dipole XA Connector consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
2.5 dia.
(See note 2)
(See note 2)
(See note 1)
2.35 dia.
+0.1
–0.05
D3M-01K3
D3M-01K3-3
OP FP
D3M D3M
6
OF
max.
1.00 N {102 gf}
RF min.
0.10 N {10 gf}
OT min.
0.7 mm
MD max.
0.6 mm
FP max.
13.6 mm
OP 11.3±
0.6 mm
Precautions
Mounting Dimensions
Use M2.3 screws, flat washers, and spring washers to mount the
D3M
securely
. Make sure that the tightening torque
applied to each
screw is within a range from 0.23 to 0.26 N
S
m {2.3 to 2.7 kgf
S
cm}.
Two, 2.4-dia. mounting hole or M2.3 screw hole
Operating
Stroke
Make
sure that the dog is separated from
the actuator when the ac
-
tuator is in the free position and that the actuator is pressed ap-
propriately when the D3M is actuated. The actuator must not be
pressed excessively to reach the maximum overtravel position,
otherwise
the D3M may be damaged.
Make
sure the actuator is pressed in the direction where the D3M is
actuated.
Correct Use
Refer
to pages
22
to
29 for common precautions.
W
iring Connectors
The terminals connect to JST’
s Dipole XA Connector
.
The Dipole XA Connector consists of the following components.
Contact: SXA-001T
-P0.6
Housing: XAP-02V
-1
OMRON
does not sell the Dipole
XA Connector
. Contact the follow
-
ing.
J.S.T.
Manufacturing Co., Ltd. (Japan)
T
el: (81)45-543-1271
Fax: (81)45-544-1503
J.S.T
. (U.K.) Ltd. (United Kingdom)
T
el: (44)1986-874131
Fax: (44)1986-874276
J.S.T
. Corporation (U.S.A.)
T
el: (1)847-473-1957
Fax: (1)847-473-0144
J.S.T
. (H.K.) Co. Ltd. (Hong Kong)
T
el: (852)24137979
Fax: (852)241
11193
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
convert millimeters into inches, multiply by 0.03937. T
o convert grams into ounces, multiply by 0.03527.
Cat. No. B100-E1-2
Stainless
steel (t = 0.3)
Note: 1. The terminals connect to JST’s Dipole XA Connector.
2. The
Dipole XA Connector consists of
the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
2.5 dia.
(See note 2)
(See note 1)
2.35 dia.
+0.1
–0.05
(See note 2)
D3M-01L3
D3M-01L3-3
OP FP