1521-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZUP Series
Features
u Constant Voltage / Constant Current
u Last Setting Memory
u Digital Meters
u Built-in RS232 & RS485 Interface w/ GPIB optional
u Bench or Rack Mount
u Embedded Microprocessor Controller
u Voltage up to 120V, Current up to 132A
Zero up programmable power supplies
Notes: (1) Recovery to within +/-50mV after load change of 50-100% (2) Over 8 hour period following 30 minute warm up time
(3) 25°C ambient (cold start)
Model ZUP6 ZUP10 ZUP20 ZUP36 ZUP60 ZUP80 ZUP120
Load Regulation - 2mV + 0.005% over 0 - 100% load change
Line Regulation - 1mV + 0.005% over 85 - 132 or 170 - 265VAC line change
Recovery Time (1) ms 1ms 0.5ms 0.2ms
Temperature Coeffi cient - 30ppm/°C following 30 minute warm up
Temperature Drift(2) - 0.01% + 2mV change in output
Up programming response time ms 50 - 60ms 80ms 120ms
Down prog. resp. time (CV) ms 50ms (70ms ZUP60-14)
Down prog. resp. time (CV) ms 250ms 350ms 400ms 500ms 750ms 600ms 800ms
Load Regulation - 0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
Line Regulation - 0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
Temperature Coeffi cient - 100ppm/°C from rated current after 30 minute warm up time
Temperature Drift(2) - 0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models
Prog Voltage resolution - Better than 0.028% of rated voltage
Prog Voltage accuracy mV .02%+5mV .02%+8mV .02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV
Prog Current resolution - Better than 0.03% of rated voltage
Prog Current accuracy - 0.4% + 40mA
Overvoltage Shutdown V 0 - 7.5 0 - 13 0 - 24 0 - 40 0 - 66 0 - 88 0 - 132
Thermal Protection - Over temperature protected
Display - Voltage - 3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
Display - Current - 3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
Display - Status - CV / CC, Alarm, Foldback, Local/Remote, On/Off
Remote On/Off - TTL signal or dry contact relay
Output Good - Open Collector
Voltage & Current Programming - By either Voltage (0-4V) or Resistance (0-4k)
Remote Sense - Up to 0.5V compensation per output cable
Communication Interface - RS232 & RS485 standard, IEEE488 optional
Series & Parallel Operation - Series: Up to two units; Parallel: Up to fi ve units in master-slave confi guration
AC Input Voltage range VAC 85-265VAC (47-63Hz)
Inrush Current (100/200VAC)(3) A 15/30A, 200W models, 15A, 400W models, 30A, 800W models
Hold Up Time (Typ) at 100VAC ms 20
Power Factor Correction - Complies with EN61000-3 Class A (0.99 typ)
Temperature Range - Operating: 0 - 50°C; Storage: -20 to +70°C
Humidity (non condensing) - Operating: 30 - 90% RH, Storage 10 - 95%RH
Cooling - Internal fan
Withstand Voltage - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance - >100M at 25°C & 70%RH
Vibration & Shock (non-op.) - Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
Safety Agency Approvals - UL3111-1, EN61010-1, CE Mark
Conducted & Radiated EMI - EN55022-B conducted, A radiated, FCC Class B conducted, A radiated, VCCI-2 conducted, -1 radiated
Warranty yrs Three Years
Specifi cations
Key Market Segments & Applications