2
Technical Data 10554
Effective July 2020
TV Supercapacitors
Cylindrical cells
www.eaton.com/electronics
Ratings10
Capacitance 3 F to 100 F
Maximum working voltage 3.0 V
Surge voltage 3.3 V
Capacitance tolerance -10% to +30% (+20 °C)
Operating temperature range -40 °C to +65 °C
Extended temperature range -40 °C to +85 °C (with linear voltage derating to 2.5 V @ +85 °C)
Specifications
Capacitance (F)
Part number
Maximum
initial ESR1
(Ω)
Nominal
leakage
current1,2
(µA) Stored energy3
(mWh) Peak power4
(W)
Pulse
current5
(A) Continuous
current6 (A)
Typical
thermal
resistance7
Rth (°C/W)
Short
circuit
current8
(A)
3 TV0820-3R0305-R 0.075 15 3.75 30 3.7 1.6 76 40
6 TV1020-3R0605-R 0.035 13 7.5 64.3 7.4 2.4 73 86
10 TV1030-3R0106-R 0.026 25 12.5 86.5 12 3.7 40 115
15 TV1325-3R0156-R 0.024 35 18.8 94 17 3.4 53 125
25 TV1625-3R0256-R 0.018 60 31.3 125 26 4.2 47 167
34 TV1245-3R0346-R 0.016 75 42.5 141 33 6.5 22 188**
35 TV1635-3R0356-R 0.015 90 43.8 150 34 5.1 39 200**
60 TV1840-3R0606-R 0.013 135 75 173 51 6.7 26 231**
100 TV1860-3R0107-R 0.011 225 125 205 71 11.7 10 273**
** Repeated short circuit current will permanently damage the leads.
Performance
Parameter Capacitance change
(% of initial value) ESR
(% of maximum initial value)
Lifetime: (1000 hours at maximum temperature and voltage) ≤ 30% ≤ 200%
Charge/Discharge Cycles9: (500,000 at +20 °C) ≤ 30% ≤ 200%
Storage: (3 years, uncharged, <35 °C) ≤ 5% ≤ 10%
1. Capacitance, Equivalent Series Resistance (ESR) and Leakage current are measured according to IEC62391-1 with current in milliamps (mA) = 8 x C x V.
2. Leakage current at +20 °C after 72 hour charge and hold.
3. Stored Energy (mWh) = 0.5 x C x V2
3600
4. Peak Power (W) = V2
4 x ESR
5. Pulse current for 1 second from full rate voltage to half voltage.(A) = 0.5 x V x C
(1 + ESR x C)
6. Continuous current with a 15 °C temperature rise. Continuous current (A) =
7. Thermal resistance (Rth) cell body temperature to ambient in open air in degrees C per Watt (°C/W).
8. Short circuit current is for safety information only. Do not use as operating current.
9. Cycling between rated voltage and half voltage, 3 second rest at +20 °C.
10. Testing and verification of product under end application conditions is recommended
Safety and Certifications
Regulatory UL810a, RoHS, REACH
Shock and vibration MIL-STD 202G
Warnings Do not overvoltage, do not reverse polarity
Shipping No restrictions, per UN3499 with all cells <0.3 watt-hours
x 1000