Product Bulletin
SW Series
Fiberoptic Switch Modules
Description
The SW Series of fiberoptic switch modules connect a single
channel to one of several (up to five) channels. In addition
to the single pole configurations, the SW Series also supports
several two pole versions, as shown schematically. Note
that the 2x4 version can be driven independently as two 1x2
switches.
Both single-mode and multimode versions are available. In
operation, the SW switch connects the optical channel by
redirecting the optical signal into a selected output fiber.
This is achieved using optical prisms driven by a highly
precise mechanism and activated via an electrical control
signal.
The use of collimating lenses minimizes the insertion loss
and improves the repeatability and stability of the switch
parameters. The SW switches are optically passive and are,
therefore, transparent to signalling formats. Configurations
can be optimized for bidirectional performance as a factory
option.
Configurations
Key Features
Typical insertion loss 0.5 dB
Return loss greater than 55 dB
Wide choice of configurations
Small size
High repeatability over a broad range of
environmental conditions
Simple control
Applications
Optical signal routing, fiber network configuration,
and restoration
Sensor switching, source/detection selection, reference,
and multisource measurements in instrumentation
Fiberoptic component testing
Research and development
Solid lines represent the unpowered (0 V DC) state of the switch.
Tel. (613) 727-1303
Fax. (613) 727-8284
sales@jdsfitel.com
www.jdsfitel.com
JDS FITEL Inc.
570 West Hunt Club Rd.
Nepean (Ottawa), Ontario
K2G 5W8 CANADA
All information contained herein is believed to be accurate and is subject to change without notice. No responsibility is assumed for its use. As this is a new/advanced product,
JDS FITEL or manufacturer are likely to make changes, and reserves the right to do so, without notice, to product design, product components and product manufacturing methods.
Some specific combinations of options may not be available. Please contact JDS FITEL Inc. for more information.
© JDS FITEL Inc. All rights reserved. MKT-DS-0025 Rev. D 02/99 Printed in Canada
Page 2
Specifications
Parameter Typical Maximum
Insertion loss single-mode1(SM) 0.5 dB 0.8 dB
multimode1(MM) 0.4 dB 0.7 dB
Return loss SM250 dB 45 dB (minimum)
SM2 (high RL) 60 dB 55 dB (minimum)
MM 25 dB 20 dB (minimum)
Polarization dependent loss2,3 SM 0.02 dB 0.07 dB
Insertion loss stability4±0.03 dB ±0.05 dB
Repeatability ±0.003 dB ±0.005 dB
Crosstalk -70 dB -60 dB
Optical input power 300 mW
Switching time510 ms 15 ms
Cycle rate 5 c/s
Operating temperature -25 to 65 °C
Storage temperature -40 to 80 °C
Humidity (non-condensing) 95%
Power65±5% V DC/45 mA (70 mA for TTL option)
Dimensions (WxHxD) SW1x1, 1x2, 2B 40 x 17 x 40 mm (fiber version)
SW1x1, 1x2, 2B 70 x 17 x 40 mm (cable version)
SW2x2 70 x 17 x 40 mm (fiber or cable version)
SW1x3, 1x4, 1x5, 2x4 70 x 17 x 70 mm (fiber or cable version)
Weight 45, 80, and 140 g
Control direct or TTL
Ordering Information
Indicate your requirements by selecting one option from each configuration table. Please print the corresponding codes in the
available boxes to form your part number. For more information on this or other products and their availability, please contact
your local JDS FITEL sales representative, or JDS FITEL directly at (613)727-1303, or by fax at (613)727-8284 or via e-mail at
sales@jdsfitel.com. Specify your requirements in detail and consult your JDS FITEL sales representative or factory to obtain a
quote. Sample: SW101+1075USPE
Code Connector Type
FA FC/APC (SM only)
FP FC/HPC
NC No connector
SU SC/APC (SM only)
SC SC/HPC
SP ST/HPC
SW Series
1. Excluding connectors. Include 0.2 dB (typical insertion loss) for each
connector. Add 0.2 dB insertion loss for 1x3, 2x2, and higher configurations.
2. Excluding connectors.
3. PDL for SW2x2 is typically 0.09 dB.
4. Drift of any channel relative to one assigned reference channel at ±3 °C
deviation of ambient temperature over a seven-day period.
5. For SW1x4, 1x5, and 2x2, the maximum switching time is 20 ms.
6. 90 mA (115 mA TTL) for SW2x4.
SW +1
Code # of Output Channels
01 1
02 2
03 3
04 4
05 5
BP Bypass
Code # of Input Channels
11
22
Code Control Type
0 Direct
2 TTL
Code Fiber Type
1 50/125
2 62.5/125
4 100/140
7 9/125
1. 1.5 m length
Code Pigtail Type1
E 900 µm tight buffer
L 3.0 mm jacketed cable
Code Wavelength
D 1300/1500 nm
3 1300 nm
5 1500 nm
8 800 nm (MM only)
Code Return Loss
L 45 dB (SM only)
U 55 dB (SM only, high RL)
M 20 dB (MM only)