ACDC 150/180 Watts GCS Series xppower.com * Convection/Forcedcooled Ratings * IT & Medical Safey Approvals (Class I & II) * < 0.5W Standby Power * 40 C to +70 C Operation * Remote On/Off (R Models) * Class B Emissions * 3 Year Warranty Specification Input * 85-264 VAC, derate output power <90 VAC by 10% Input Frequency * 47-63 Hz Input Current * 1.5/1.8 A typical at 115 VAC, full load (150/180 W) 0.7/0.8 A typical at 230 VAC, full load (150/180 W) Inrush Current * 80 A typical at 230 VAC, cold start at 25 C Power Factor * EN61000-3-2, class A & C Earth Leakage Current * 200 A max at 264 VAC/60 Hz No Load Input Power * <0.5 W Input Protection * Internal T3.15 A/250 V fuse in line and neutral Input Voltage Output * 12-48 VDC (see Models & Ratings table) * 2%, fan output will track by same percentage Initial Set Accuracy * 1% V1, 5% V Fan Minimum Load * None Start Up Delay * 0.5 s max Hold Up Time * 18 ms typical Drift * 0.2% after 20 min warm up Line Regulation * 0.5% max Load Regulation * 0.5% V1, 5% V Fan Over/Undershoot * 12 - 28 V models none, 48 V models typically 5% Transient Response * 4% max. deviation, recovery to within 1% in 500 s for a 50-75-50% load change Ripple & Noise * 1% pk-pk V1, 12 V models 1.5%, 20 MHz bandwidth Overvoltage Protection * 115-140% Vnom, recycle input to reset Overload Protection * 110-150% V1 only Short Circuit Protection * Continuous Temperature * 0.05%/C Coefficient Remote Sense * Compensates for 0.5 V total voltage drop Remote On/Off * Optional, -R models (see longform datasheet for full details) Output Voltage Output Voltage Trim General Efficiency Isolation Switching Frequency MTBF Power Density * 93% typical * 4000 VAC Input to Output 2 x MOPP, 1500 VAC Input to Ground 1 x MOPP, 500 VDC Output to Ground * 65/100 KHz PFC/Main Converter * 569 kHrs to MIL-HDBK-217F at 25 C, GB * 8.5 W/in3 Environmental Operating Temperature * -40 C to +70 C derate linearly from +50 C at 2.5%/C to 50% load at +70 C Cooling * Convection & Fan cooled ratings (see Models & Ratings tables) Operating Humidity * 95% RH, non-condensing Storage Temperature * -40 C to +85 C Operating Altitude * 3048 m Shock * 3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/-0.5msec), half sine, conforms to EN60068-2-27 & EN60068-2-47 Vibration * Single axis 10 - 500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 EMC & Safety Low Voltage PSU EMC * EN61204-3, high severity level Emissions * EN55011/22 level B conducted EN55011/22 level B radiated (GCS180 level A) Harmonic Currents * EN61000-3-2, class A & C Voltage Flicker * EN61000-3-3 Radiated Immunity * EN61000-4-3, level 3 Perf Criteria A EFT/Burst * EN61000-4-4, level 3 Perf Criteria A Surge * EN61000-4-5, installation class 3 Perf Criteria A Conducted Immunity * EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions * EN55024 & EN60601-1-2 (see longform datasheet for details) Safety Approvals * EN60601-1, ANSI/AAMI ES60601-1, CSA22.2 No. 60601-1 per cUL, Including Risk Management, EN60950, UL60950 Output Current V1 Convection Cooled Forced Cooled (7 CFM) 9.2 A 12.5 A 7.3 A 10.0 A 4.6 A 6.3 A 3.9 A 5.4 A 2.3 A 3.2 A Output Voltage V1 12.0 15.0 24.0 28.0 48.0 VDC VDC VDC VDC VDC 12.0 15.0 24.0 28.0 48.0 VDC VDC VDC VDC VDC 12.5 10.0 6.3 5.4 3.1 A A A A A 15.0 12.0 7.5 6.4 3.7 Output Voltage (Vfan) & Current A A A A A Maximum Output Power Model Number(1,2,3,4) 12.0 12.0 12.0 12.0 12.0 VDC/0.6 VDC/0.6 VDC/0.6 VDC/0.6 VDC/0.6 A A A A A 157 157 157 157 157 W W W W W GCS150PS12 GCS150PS15 GCS150PS24 GCS150PS28 GCS150PS48 12.0 12.0 12.0 12.0 12.0 VDC/0.6 VDC/0.6 VDC/0.6 VDC/0.6 VDC/0.6 A A A A A 187 187 187 187 187 W W W W W GCS180PS12 GCS180PS15 GCS180PS24 GCS180PS28 GCS180PS48 Notes 1. Add suffix -C for convection cooled cover, e.g. GCS150PS12-C. 2. Add suffix -EF for fan cooled cover with end fan e.g. GCS150PS12-EF. Note Vfan output no longer available. 3. Add suffix -TF for fan cooled cover with top fan, e.g. GCS150PS12-TF. Note Vfan output no longer available. 4. Add suffix -R for remote on/off, e.g. GCS150PS12-R, GCS150PS12-RC with convection cover or GCS150PS12-REF/GCS150PS12-RTF with fan covers. Mechanical Details Note: Mounting points A should be connected together for optimum EMI performance 5.0 (127.0) 0.225 (5.72) 4.5 (115.57) 1.42 (36.3) 0.20 (5.1) T1 Q3 3.00 (76.2) AIRFLOW 2.15 (54.6) C45 A 2.40 (61.0) C23 2.55 (64.7) C6 Q1 C28 L3 A A 0.225 (5.72) 0.20 (5.1) 0.25 Faston Ground Tab Signal Connector Molex pn. 09-65-2068 Pin 1 2 Function Line Neutral Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN 1.18 (29.8) 0.14 (3.5) 4 x 0.156 (3.96) mounting holes o.312 (7.92) clearance top and bottom Input Connector J1 Molex pn. 09-65-2038 0.61 (15.6) 0.18 (4.6) 0.15 (3.8) SMD Component Height Signal Connector Molex pn. 09-65-2068 Fan Connector J3 Molex pn. 22-04-1021 Pin 1 2 Function Fan +(12 V) Fan - Pin 1 2 3 4 5 6 7 8 9 10 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-161 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 22-01-1024 and with Molex series 5103 crimp terminals. ACDC GCS150/180 Models and Ratings Convection (C) 0.39 (10.0) 4.72 (120.0) 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 0.93 (23.7) 5.50 (139.7) 1 1 3.48 (88,5) 10 1 2 J4 1 2 Pin 1 2 2.64 (67.0) 0.85 (21.6) 0.43 (10.8) 0.45 (11.4) 0.25 Faston Ground Tab J3 6 J2 J1 Input Connector J1 Molex pn. 09-65-2038 2 2.39 (60.7) 0.45 (11.4) 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration Pin 1 2 3 4 5 6 7 8 9 10 4.72 (120.0) 0.39 (10.0) 4.72 (120.0) 2 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 0.93 (23.7) Single Output +V1 +V1 +V1 RTN RTN RTN Signal Connector Molex pn. 09-65-2068 0.76 (19.3) Top Fan (TF) Pin 1 2 3 4 5 6 1.96 (50.0) 0.39 (10.0) Function Line Neutral Signal Connector Molex pn. 09-65-2068 1.70 (43.2) Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C 5.5 (139.7) 1 0.25 Faston Ground Tab 0.43 (10.8) 3.48 (88,5) 2.64 (67.0) Notes J4 10 1 2 1 0.45 (11.4) J3 6 J2 1 J1 2 2.39 (60.7) 2 ACDC GCS150/180 Models and Ratings 0.85 (21.6) 0.45 (11.4) 2.2 (57.8) 1.7 (43.2) 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 1.96 (50.0) 0.76 (19.3) 0.39 (10.0) 4.72 (120.0) 1. All dimensions in inches (mm). 2. Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-161 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 22-01-1024 and with Molex series 5103 crimp terminals. End Fan (EF) 6.35 (161.3) 0.43 (10.8) J4 J3 6 1 0.45 (11.4) 0.25 Faston (Right Angle) Ground Tab 1.70 (43.2) 0.93 (23.7) 0.39 (10.0) Pin 1 2 3 4 5 6 Single Output +V1 +V1 +V1 RTN RTN RTN Signal Connector Molex pn. 09-65-2068 4.72 (120.0) Pin 1 2 3 4 5 6 7 8 9 10 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 0.76 (19.3) 1.96 (50.0) 0.39 (10.0) J1 2 1 0.45 (11.4) 2 x M3 x 0.5 THD 0.16 (4.0) max screw penetration Signal Connector Molex pn. 09-65-2068 1.10 [27.8] 0.84 (21.5) 5.50 (139.7) Function Line Neutral J2 2.63 (66.9) 10 1 2 3.48 (88.5) Pin 1 2 1 2 1.90 (48.2) Input Connector J1 Molex pn. 09-65-2038 Single Output +Sense -Sense XP Internal Use Inhibit LO Inhibit HI N/C N/C N/C N/C N/C 4.72 (120.0) Notes 1. All dimensions in inches (mm). 2. Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-161 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 22-01-1024 and with Molex series 5103 crimp terminals. Thermal Considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). See Mechanical Details for component locations. See longform datasheet for further information and service life estimates. Component T1 Coil L3 Coil Q1 Body Q3 Body C6 C23 Temperature Measurements (Ambient 50 C) Max Temperature C 120 C 120 C 120 C 120 C 105 C 105 C 28-Feb-13 ACDC GCS150/180 Models and Ratings