139www.lumberg-automationusa.com 1-717-217-2299
Be Certain with Belden
Cordsets
Double-Ended
M8-Double-Ended Cordsets for Actuators, Sensors and Distribution Boxes
RSMV-RKM | RSMV-RKMV
Technical Data
Environmental
Degree of protection IP 65 / IP 67 / NEMA 6P
Operating temperature range -40°C (-40°F) / +90°C (+194°F)
Mechanical
Housing / Molded body TPU, self-extinguishing
Insert PA / TPU
Contact CuZn, pre-nickeled and
0.8 microns gold-plated
Coupling nut CuZn, nickel-plated (only RSMV / RKMV)
Electrical
Nominal current at 40°C 4 A
Nominal voltage 60 V
Rated voltage 63 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Pollution degree 3
Cable Specifications
Cable No. Outer Jacket Gauge Jacket
Color OD Agency Approvals
224 PUR, halogen-free 3 x 0.34 mm2Black .169” (4.3 mm) UL: AWM 21198 / CSA: AWM I/II A/B
Part Number Pins Standard Cable Lengths Characteristics
RSMV 3-RKM 3-224/...M 30.6 M / 1 M / 2 M
RSMV 3-RKMV 3-224/...M 0.6 M / 1 M / 2 M
Cordsets
Double-Ended