(888) IPD-CONVerters (888) 473-2668 www.ipdconverters.com
C-68
55
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOA D %
EFFICIENCY %
EFF. IWD1209
EFF. IWD1212
50
55
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
EFF. IWD505
EFF. IWD512
TECHNICAL SPECIFICA TIONS
General
DESCRIPTION FEATURES
Efficiency vs. Load (12V Input)
Efficiency vs. Load (5V Input)
IWD SERIES - DUAL OUTPUT, 10 WATT
Notes
1 Converter will auto-restart once fault has been removed.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
IWD dual output DC/DC converters offer excellent
regulation and isolation in an industry standard
package. Available in 5V and 12V input versions, the
IWD is perfect for industrial, datacom, or telecom
applications. The IWD features short circuit
protection and 500 VDC isolation. Please see the IWS
and IAS series for single output applications.
Industry Standard Package
Industry Standard Pinout
85°C Case Operation
Short Circuit Protection
5V and 12V Inputs
Input Pi Filter
6-Sided Shielding
Wide Input Voltage
500V Isolation
Switching Frequency 300 kHz
Isolation
Input - Output 500 VDC
Isolation Resistance - Input to Output 109 Ohms
Standard Case Operating Range -25 to +85°C
Industrial Range (add -I to p/n) -40 to +85°C
Storage Range -40 to +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 min each 5 g, 10 - 55 Hz
Safety UL, CUL, TUV
Weight (approx.) 1.4 oz
Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., Iout Rated ±1.0% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. ±1.0% Vout
Minimum Output Current 10 % Iout Rated
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 1% Vout
Settling Time 500 µs
Temperature Coefficient 0.02%/°C
Ripple and Noise, 20 MHz BW 1% Vout nom.
Short Circuit Protection 1Hiccup
Current Limit 130%
Output
Input
Voltage Range
5 VDC Nominal 4.5 - 9 VDC
12 VDC Nominal 9 - 18 VDC
Reflected Ripple 20% Iin Max.
Reverse Input Current 100% Iin Max.
C-69
Thermal Impedance
Natural convection 15.4 °C/W
100 LFM 12.2 °C/W
200 LFM 9.3 °C/W
300 LFM 7.4 °C/W
400 LFM 6.4 °C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
IWD SERIES - DUAL OUTPUT, 10 WATT
MECHANICAL DRAWING
Pin Function
1+V
in
2-V
in
3+ V
out
4 Common
5- V
out
Tolerances
Inches: (Millimeters)
.XX ± 0.040 .X ± 1.0
.XXX ± .010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
Case:
+ 0.04, - 0.00 + 1.0, - 0.0
(T olerances as listed unless otherwise specified.)
MODELS - (See the last page of this file for options.)
Vin
(Volts) Vi n Range
(Volts) Iin Max.*
(Amps) Vout
(Volts) Iout Rated
(Amps) Rip p le & No ise
Pk-Pk (mV) Efficiency
Typ. ** Model
5
5
5
12
12
12
4.65 - 5.5 0
4. 65 - 5. 50
4. 65 - 5. 50
10.90 - 13. 20
10.90 - 13. 20
10.90 - 13. 20
3.20
3.20
3.20
1.55
1.55
1.55
±5
±12
±15
±5
±12
±15
±1.000
±0.500
±0.375
±1.000
±0.500
±0.375
50
120
150
50
120
150
82%
80%
82%
80%
84%
82%
IWD505
IWD512
IWD515
IWD1205
IWD1212
IWD1215
* Max imu m inpu t cur rent at m i nim um i nput v olt ag e, ma x i mu m ra te d o ut p ut p ower.
** At nominal Vin, rated output.
1.40"(35.6mm)
BOTTOM VIEW
0.800"(20.3mm)
0
(4.6mm)
0.18" MIN.
(1.0mm)
DIA 0.040"
(10.2mm)
0.40"
(50.8mm)
2.00"
(25.4mm)
1.00"
4
2
53
1
(-2.5mm)
-0.10"
0(20.3mm)
0.800"
(7.6mm)
0.300"
(10.2mm)
0.400"
(12.7mm)
0.500"
C105
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y E ncapsulated EWS, IWS, OWS
PIN LENGTH A ND HEAT SINK
OPTIONS Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length 8 All Units (E xcept SMS)
0.150” (3.8mm) Pin Length 9 All Units (E xcept SMS)
0.24” (6.1mm) Horizontal Heatsi nk 1H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink 2H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink 3H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.