AC AXIAL FANS
Tel: 425-222-5900 800-453-4569www.mechatronics.com E-mail: Sales@Mechatronics.com Fax: 425-222-5155 Cooling Simplified
Model No.
Rated
Voltage
V
Freq.
HZ
Input
Power
W
Rated
Cur.
A
Locked
Cur.
A
Speed
RPM
Air Volume Ma x. Sta tic
Pressure (H20)
Sound
Noise
dbA
Weight
kg
/Min. CFM MM INCH
UF80B12-_ _H 115 60 11 0.12 0.13 3,100 0.68 24 5.5 0.22 35 0.26
UF80B23-_ _H 230 60 14 0.07 0.08 3,100 0.68 24 5.5 0.22 35 0.26
UF80B12-_ _L 115 60 11 0.12 0.13 2,400 0.50 18 3.5 0.14 31 0.26
UF80B23-_ _L 230 60 14 0.06 0.07 2,400 0.50 18 3.5 0.14 31 0.26
(80 x 80 x 25 mm)
3.15 x 3.15 x 0.98 inches
Operating voltage: 115 or 230 VAC
Construction: aluminum die cast frame;
UL94V-0 PBT impeller
Bearing option: ball bearing or sintered bronze
sleeve
Motor: shaded pole
Air Flow: exhaust over struts
Connection: terminal or 22 AWG lead wire
Protection: impedance
Options: dual voltage 115/230VAC,
IP55; IP55 + salt fog
.25
.20
.15
.10
.05
0510 15 20 25
AIR FLOW (CFM)
STATIC PRESSURE - IN. OF WATER
L
H
UF80B series
3.15 ±0.02
(80 ±0.5)
2.81 ±0.01
(71.5 ±0.3) Ø0.17
(Ø4.3 ±0.2)
TERMINAL TYPE
LEAD WIRE TYPE
.98 ±0.02
(25 ±0.5)
0.16
(4)
0.12
(3)
0.35
(8.5)
0.31
(8)
Ø2.99
(Ø76)
12.20.18