DC/DC CONVERTERS 8-10W Wide Input DC/DC Converters 1
2 YEAR WARRANTY
BXA10 Series
Single and dual output
•1 x 2 x 0.395 inch package with stand-offs
•13.3 Watts/in3power density
•CISPR22 and EN55022 conducted emission level A
•UL, CSA and VDE approvals (48V input only)
•Continuous short circuit protection
•Optional remote ON/OFF
The BXA10 series of DC/DC converters, comprising 7 different models, is designed for
a wide range of applications including communications, industrial systems and mobile
battery powered systems. Packing up to 10 Watts of power into a 2 x 1 x 0.395 inch
package, with efficiencies as high as 85%, the BXA10 has wide input ranges of 9-18VDC
and 18-75VDC, and is available in single and dual output versions. Isolation of 1500VDC,
approval to EN60950 2nd edition, coupled with reduced conducted noise for simplified
compliance to FCC Part 15 level A and EN55022 level A, make the BXA10 ideal for
telecommunications and distributed power applications. Other features include
overvoltage protection, continuous short circuit protection with automatic recovery and
remote on/off, all of which minimize the need for external circuitry and make the BXA10 a
recommended component in distributed power systems.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC, (See Note 8) Level A
ESD air EN61000-4-2, level 2 Perf. criteria 1
ESD contact EN61000-4-2, level 3 Perf. criteria 1
Surge EN61000-4-5, level 2 Perf. criteria 1
Fast transients EN61000-4-4, level 2 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output 1500VDC
Input or output to case 1000VDC
Switching frequency Fixed 400kHz
Approvals and Safety VDE0805, EN60950, IEC950
standards UL1950, CSA C22.2 No. 950
Case material Black coated, six-sided metal case
Material flammability UL94V-0
Weight 20g (0.71oz)
MTBF MIL-HDBK-217F 519,000 hours
Bellcore >2 million hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -25°C to +71°C
(See derating curve)
Non-operating amb. -55°C to +125°C
Case +110°C max.
Derating See derating curve
Cooling Free air convection cooled
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non operating 40,000 feet max.
Vibration 5Hz to 500Hz 2.5G rms (approx.)
SPECIFICATIONS
File Name: bxa10.pdf Rev: 10 August 2005
OUTPUT SPECIFICATIONS
Line regulation LL to HL, single output ±0.2%
LL to HL, dual output ±0.2%
Load regulation 10% to 100% FL (See Note 4) ±0.5%
Minimum load 48V models 10% full load
12V models No minimum load
Overshoot At start-up 10% max.
Ripple and noise 5Hz to 20MHz 100mV pk-pk, max.
(See Note 2) 20mV rms
Transient response 25% load step ±2.0% max. dev.,
250µs recovery
to within ±1.0%
Temperature coefficient ±0.02%/°C max.
Overvoltage protection Clamp type See table
Short circuit protection Hiccup Continuous
automatic recovery
INPUT SPECIFICATIONS
Input voltage range 12VDC (See Note 6) 9 to 18VDC
48VDC 18 to 75VDC
Input filter Pi type
Start up surge current Resistive load 1.5A max.
Remote ON/OFF Open collector compatible
ON (See Note 3) High impedance >400kΩ
OFF Low impedance <1.0kΩ
OFF idle current <1.5mA
Start-up time 1.6s, max.