Series PVT412PbF
2 www.irf.com © 2015 International Rectifier Submit Datasheet Feedback May 18, 2015
OUTPUT CHARACTERISTICS PVT412L PVT412
Operating Voltage Range 0 to ±400 V(DC or AC peak)
Maximum Load Current @ TA=+40°C
5mA Control (see figures1 and 2)
A Connection 120 140 mA (AC or DC)
B Connection 130 150 mA (DC)
C Connection 200 210 mA (DC)
Maximum On-State Resistance @TA=+25°C
For 50mA Pulsed Load, 5mA Control (see figure 4)
A Connection 35 27 Ω
B Connection 18 14 Ω
C Connection 9 7 Ω
Maximum Off-State Leakage @TA=+25°C, ±400V (see figure 5) 1.0 µA
Current Limit @TA=+25°C, For 5mA Control Current:
Connection: AC
Minimum 130 260 n/a mA
Maximum 220 440 n/a mA
Complies with FCC Part 68 Surge Requirements* yes yes
Maximum Turn-On Time @TA=+25°C (see figure 7)
For 50mA, 100 VDC load, 5mA Control 2.0 ms
Maximum Turn-Off Time @TA=+25°C (see figure 7)
For 50mA, 100 VDC load, 5mA Control 0.5 ms
Maximum Thermal Offset Voltage @ 5mA Control 0.5 µV
Maximum Output Capacitance @ 50VDC 12 pF
GENERAL CHARACTERISTICS ALL MODELS
Minimum Dielectric Strength, Input-Output 4000 VRMS
Minimum Insulation Resistance, Input-Output @TA=+25°C, 50%RH, 100VDC 1012 Ω
Maximum Capacitance, Input-Output 1.0 pF
Maximum Pin Soldering Temperature (10 seconds maximum) +260
Ambient Temperature Range: Operating -40 to +85 °C
Storage -40 to +100
INPUT CHARACTERISTICS Part Numbers Units
PVT412L PVT412
Minimum Control Current (see figures 1 and 2) 3.0 mA
Maximum Control Current for Off-State Resistance 0.4 mA
Control Current Range (Caution: current limit input LED, see figure 6) 3.0 to 25 mA
Maximum Reverse Voltage 6.0 V
Electrical Specifications (-40°C ≤ TA ≤ +85°C unless otherwise specified)
International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications.
Users of this International Rectifier product in such applications assume all risks of such use and indemnify International
Rectifier against all damages resulting from such use.