Inductive sensor
Bi7-M18-AD4X-H1141
●threaded barrel, M18 x 1
●chrome-plated brass
●2-wire DC, 10...65 VDC
●normally open
●connector M12 x 1
Wiring diagram
Function principles
Inductive proximity switches are designed
for wear-free non-contact detection of me-
tal objects. For this they use a high-fre-
quency electro-magnetic AC field that
interacts with the target. With inductive
sensors, this field is generated by an LC re-
sonant circuit with a ferrite core coil.
+ ()
(+)
3 BN
4 BU
Type Bi7-M18-AD4X-H1141
Ident-No. 4414541
Rated operating distance Sn 7 mm
Mounting mode flush
Hysteresis (switching distance) 1... 15 %
Min. repeat accuracy ≤ 2 %
Temperature drift ≤ ± 10 %
Operating temperature -25 ...+ 70 °C
Rated operational voltage (DC) UB10... 65 VDC
Max. ripple ≤ 10 % Upp
Rated operational current (DC) Ie≤ 100 mA
Max. OFF-state current ≤ 0,6 mA
Max. switching frequency ≤ 1 kHz
Rated insulation voltage ≤ 0,5 kV
Short-circuit protection yes, cyclic
Max. voltage drop at Ie≤ 5 V
Min. operational current Im≥ 3 mA
Housing style threaded barrel; M18 x 1
Dimensions 52 mm
Housing material metal, CuZn, chrome-plated
Active face plastic, PA12-GF30
Max. fixing torque of coupling nut 25 Nm
Wiring connector, M12 x 1
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 x g (11 ms)
Degree of protection IP67
Switching status indication LED yellow
24/4
36
52
LED
M18 x 1
9
M12 x 1