■Ratings
●Coil
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
■Characteristics
Note. Values in the above table are the initial values at 23°C.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric
strength using a 500 VDC ohmmeter.
*3. This value was measured at a switching frequency of 120 operations/min.
*4. Sealed (G5NB-1A4, -1A4-E): -40°C to 70°C
■Actual Load Life (Reference Values)
1. 120 VAC motor and lamp load
2.5A surge and 0.5A normal:
250,000 operations min. (at 23°C)
2. 160 VDC valve load (with varistor)
0.24A:
250,000 operations min. (at 23°C)
3. 140 VAC pump load
Inrush: 5.4 A (o-p), Steady state: 1.6 A
200,000 operations min. (Ambient temperature: 23°C)
4. 100 VAC motor load
Inrush: 10.7 A (o-p), Steady state: 1.1 A
200,000 operations min. (Ambient temperature: 23°C)
Item Rated current
(mA)
Coil resistance
(Ω)
Must operate voltage
(V)
Must release voltage
(V)
Max. voltage
(V) Power consumption
(mW)
Rated voltage % of rated voltage
5 VDC 40 125
75% max. 10% min.
Standard:
180% (at 23°C)
High-capacity:
170% (at 23°C)
Approx. 200
12 VDC 16.7 720
18 VDC 11.1 1,620
24 VDC 8.3 2,880
Item Load Resistive load
Standard High-capacity
Contact Type Single
Contact material Ag-alloy (Cd free)
Rated load 3 A at 125 VAC 5 A at 250 VAC
3 A at 30 VDC 3 A at 30 VDC
Rated carry current 3 A 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 3 A 5 A
Contact resistance *1 100 mΩ max.
Operate time 10 ms max.
Release time 10 ms max.
Insulation resistance *2 1,000 MΩ min.
Dielectric
strength
Between coil
and contacts 4,000 VAC, 50/60 Hz for 1 min
Between
contacts of the
same polarity
750 VAC, 50/60 Hz for 1 min
Impulse
withstand
voltage
Between coil
and contacts 10 kV (1.2 x 50 μs)
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 100 m/s2
Durability
Mechanical 5,000,000 operations min.
Electrical
(resistive load)
Standard (G5NB-1A, -1A4)
200,000 operations at 125 VAC, 3A
200,000 operations at 30 VDC, 3A
High-capacity (G5NB-1A-E, -1A4-E)
100,000 operations at 250 VAC, 5A
200,000 operations at 30 VDC, 3A
(with a rated load at 1,800 operations/hour)
Failure rate (P level)
(reference value) *3 DC5V 10mA
Ambient operating
temperature *4
-40°C to 85°C
(with no icing or condensation)
Ambient operating humidity 5% to 85%