V15
2
INPUT SPECIFICATIONS:
Voltage …....………........….................................................. 90~264Vac
Frequency ……………………………………….....…..…………..... 47 to 63Hz
Inrush Current ……………….......... Cold Start @25℃ 80A max. @240Vac
Conducted EMI …………………………….…………… CISPR/FCC Class B
Leakage Current ………………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit Protection ………………………….…..…....…....… Continuous
Over Voltage Protection ………………..........................................…..… Yes
Temperature Coefficient ……………..………............................… ±0.05%/℃
GENERAL SPECIFICATIONS:
NOTE:
Isolation ………………………………………… Input to output = 4,242VDC
1. Voltage accuracy at 60% full load
Operating Temperature .............................. 0 ~ 70℃ (see derating curve)
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Storage Temperature ……………………………...….......……........ -20~85℃
Ripple & Noise measurement @20MHz BW.
Humidity …………………...….......……........ 93% RH max. Non condensing
3. Line regulation measured from 100Vac to 240Vac, full load.
Cooling………………………………………………………. Natural Convection
4. Load regulation measured from 60% to 100% full load and from 60% to
Switching Frequency …………………………………………… 60KHz Typical
20% full load (60% +/- 40% full load).
MTBF ……… MIL-HDBK-217F, GB, at 25℃/115VAC ………. 200K hrs min.
5. Typical efficiency at 230VAC and full load at 25 .℃
Altitude …………………………………………………………………… 2000m
Dimensions ………. 5.197x2.283x1.201 inches (132.00x58.00x30.50 mm)
Weight ……………………………………..……………… 345g(0.76 Pounds)
AC Inlet …………………………………………..…………………. IEC320/C8
SAFETY AND EMC:
Emission and lmmunity ………… EN55022 Class B, FCC Part 15 Class B
EN61000-6-3,EN61000-3-2,EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety ………………………………… IEC60950-1, EN60950-1, UL60950-1
IEC320/C8
70.866[1800.00]±1.969[50.00]
LED
2.283[58.00]
5.197[132.00]
1.201[30.50]
DC Plug :Right Angle(ψ5.5/ψ2.1) L12mm
18AWG/1800mm
DC Plug type: V+ ─●)─ V-
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
0%
20%
40%
60%
80%
0 10 20 30 40 50 60 70
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)