Limit and Enclosed Switches HDLS Series
Plunger Actuated Switches
A40Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
ASSEMBLED CONDITIONS
Catalog listings in order guide below are
factory assembled with:
1Side plungers facing front (label side) of
switch. Rollers on side plungers are in
horizontal position.
ORDER GUIDE
Momentary action, except for maintained
contact LSG version. UL listed, CSA
certified.
1Roller on top plungers are parallel to
mounting surface.
1Lights on indicator versions are wired to
N.O. circuit.
Refer to facing page to specify modifica-
tions to these assembled conditions.
For low temperature, high temperature
or preleaded versions see page A42.
Circuitry For Maintained Plunger
SPDT Double Break DPDT Double Break
(Electrical rating A) (Electrical rating B)
Circuits on any one pole must be the same polarity.
Catalog Listings
Top Plungers Side Plungers
Catalog listings in this chart
are complete switches.
Elec. Maintained
(Circuitry
Shown
Above)
Rating Body**
Circuitry Page A34 Style Plain Roller Adjustable Plain Roller Adjustable
Silver contacts A Plug-in LSC1A LSD1A LSV1A LSE1A LSF1A LSW1A LSG1A
1⁄2NConduit
Gold cross pt.
Gold plated C
C Plug-in LSC1J LSD1J LSV1J LSE1J LSF1J LSW1J —
1⁄2NConduit — LSD1E — — LSF1E LSW1E —
Silver contacts A* 120 V. Ind. Lite LSC5A LSD5A LSV5A LSE5A LSF5A LSW5A LSG5A
Plug-in
1⁄2NConduit*
A* 240 V. Ind. Lite LSC8A LSD8A LSV8A LSE8A LSF8A LSW8A LSG8A
Plug-in
1⁄2NConduit*
A Non plug-in LSC3K LSD3K LSV3K LSE3K LSF3K LSW3K LSG3K
1⁄2NConduit
SPDT
Double Break
Silver contacts B Plug-in LSC2B LSD2B LSV2B LSE2B LSF2B LSW2B LSG2B
3⁄4NConduit
B 120 V Ind. Lite LSC2R LSD2R LSV2R LSE2R LSF2R LSW2R LSG2R
Plug-in
3⁄4NConduit
B Plug-in LSC6B LSD6B LSV6B LSE6B LSF6B LSW6B LSG6B
1⁄2NConduit
B Non plug-in LSC4L LSD4L LSV4L LSE4L LSF4L LSW4L LSG4L
3⁄4NConduit
B Non plug-in LSC7L LSD7L LSV7L LSE7L LSF7L LSW7L LSG7L
1⁄2NConduit
DPDT
Double Break
D Non plug-in — — — LSE3N LSF3N LSW3N LSG3N
1⁄2NConduit
SPNC
Direct Acting
*Use at voltage indicated for light. Upper operating temperature limit for lighted units is 200°F. Wired to N.O. circuit. **Plug-in listings include base receptacle.
OPERATING CHARACTERISTICS
mm 1,78 1,78 1,78 2,54 2,54 2,54 4,32
Pretravel (in. max.) .070 .070 .070 .100 .100 .100 .170
0,38 0,38 0,38 0,64 0,64 0,64 2,29
SPDT .015 .015 .015 .025 .025 .025 .090
Differential mm 0,51 0,51 0,51 0,89 0,89 0,89 2,29
Travel (in. max.) DPDT .020 .020 .020 .035 .035 .035 .090
mm 4,83 4,83 4,83 4,83 4,83 4,83 2,0
Overtravel (in. min.) .190 .190 .190 .190 .190 .190 .080
Newton 17,8 17,8 17,8 26,7 26,7 26,7 44,5
Operating Force (lb. max.) 4 4 4 6 6 6 10
Operating Point mm
(in.)
45,8 ±0,76 55,9 ±1,02 53,0 to 59,3 33,0 ±0,76 44,1 ±1,02 41,0 to 47,4 37,6 ±0,76
1.805 ±.030 2.200 ±.040 2.085 to 2.335 1.300 ±.030 1.735 ±.040 1.615 to 1.865 1.480 ±.030
Operating Temperature
Range
10°F to 200°F10°F to 200°F10°F to 200°F30°F to 200°F
–12 to 93°C –12 to 93°C –12 to 93°C –1 to 93°C