Programmable Dual-Axis Inclinometer/Accelerometer ADIS16201 FEATURES FUNCTIONAL BLOCK DIAGRAM AUX ADC AUX DAC VREF ADIS16201 TEMPERATURE SENSOR DUAL-AXIS ACCELEROMETER SIGNAL CONDITIONING AND CONVERSION CALIBRATION AND DIGITAL PROCESSING CS SCLK SPI PORT DIN DIGITAL CONTROL SELF-TEST DOUT VDD POWER MANAGEMENT ALARMS AUXILIARY I/O COM RST DIO0 DIO1 05462-001 Dual-axis inclinometer/accelerometer measurements 12-, 14-bit digital inclination/acceleration sensor outputs +1.7 g accelerometer measurement range +90o inclinometer measurement range, linear output 12-bit digital temperature sensor output Digitally controlled sensitivity and bias calibration Digitally controlled sample rate Digitally controlled frequency response Dual alarm settings with rate/threshold limits Auxiliary digital I/O Digitally activated self test Digitally activated low power mode SPI(R)-compatible serial interface Auxiliary 12-bit ADC input and DAC output Single-supply operation: 3.0 V to +3.6 V 3500 g powered shock survivability Figure 1. APPLICATIONS Platform control, stabilization, and leveling Tilt sensing, inclinometers Motion/position measurement Monitor/alarm devices (security, medical, safety) GENERAL DESCRIPTION The ADIS16201 is a complete, dual-axis acceleration and inclination angle measurement system available in a single compact package enabled by the Analog Devices iSensorTM integration. By enhancing the Analog Devices iMEMS(R) sensor technology with an embedded signal processing solution, the ADIS16201 provides factory calibrated and tunable digital sensor data in a convenient format that can be accessed using a serial peripheral interface (SPI). The SPI interface provides access to measurements for dual-axis linear acceleration, dualaxis linear inclination angle, temperature, power supply, and one auxiliary analog input. Easy access to calibrated digital sensor data provides developers with a system-ready device, reducing development time, cost, and program risk. Unique characteristics of the end system are accommodated easily through several built-in features, such as a single command in-system offset calibration, along with convenient sample rate and bandwidth control. The ADIS16201 offers the following embedded features, which eliminate the need for external circuitry and provide a simplified system interface: * Configurable alarm function * Auxiliary 12-bit ADC * Auxiliary 12-bit DAC * Configurable digital I/O port * Digital self-test function The ADIS16201 offers two power management features for managing system-level power dissipation: low power mode and a configurable shutdown feature. The ADIS16201 is available in a 9.2 mm x 9.2 mm x 3.9 mm laminate-based land grid array (LGA) package with a temperature range of -40C to +125C. Rev. A Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 (c)2006 Analog Devices, Inc. All rights reserved. ADIS16201 TABLE OF CONTENTS Features .............................................................................................. 1 Calibration Register Definitions .............................................. 19 Applications....................................................................................... 1 Alarms.......................................................................................... 21 Functional Block Diagram .............................................................. 1 Sample Period Control .............................................................. 23 General Description ......................................................................... 1 Filtering Control......................................................................... 24 Revision History ............................................................................... 2 Power-Down Control ................................................................ 24 Specifications..................................................................................... 3 Status Feedback........................................................................... 25 Timing Specifications .................................................................. 5 Command Control..................................................................... 25 Timing Diagrams.......................................................................... 5 Miscellaneous Control Register................................................ 26 Absolute Maximum Ratings............................................................ 6 Peripherals ....................................................................................... 27 ESD Caution.................................................................................. 6 Auxiliary ADC Function........................................................... 27 Pin Configuration and Function Descriptions............................. 7 Auxiliary DAC Function ........................................................... 27 Typical Performance Characteristics ............................................. 8 General Purpose I/O Control ................................................... 28 Theory of Operation ...................................................................... 13 Applications..................................................................................... 29 Accelerometer Operation .......................................................... 13 Serial Peripheral Interface (SPI)............................................... 29 Inclinometer Operation............................................................. 13 Hardware Considerations ......................................................... 29 Temperature Sensor ................................................................... 14 Grounding and Board Layout Recomendations .................... 29 Basic Operation............................................................................... 15 Bandgap Reference..................................................................... 30 Data Output Register Access..................................................... 15 Power-On Reset Operation....................................................... 30 Programming and Control............................................................ 17 Second-Level Assembly ............................................................. 30 Control Register Overview........................................................ 17 Example Pad Layout................................................................... 30 Control Register Access ............................................................. 17 Outline Dimensions ....................................................................... 31 Control Register Details................................................................. 19 Ordering Guide .......................................................................... 31 Calibration................................................................................... 19 REVISION HISTORY 5/06--Rev. 0 to Rev. A Changes to Figure 3.......................................................................... 5 Changes to Figure 35...................................................................... 18 Changes to Status Feedback Section ............................................ 25 3/06--Revision 0: Initial Version Rev. A | Page 2 of 32 ADIS16201 SPECIFICATIONS TA = -40oC to +125C, VDD = 3.3 V, tilt = 0, unless otherwise noted. Table 1. Parameter INCLINOMETER Input Range Relative Accuracy Sensitivity Sensitivity over Temperature Offset Offset over Temperature ACCELEROMETER Input Range 1 Nonlinearity1 Alignment Error Cross Axis Sensitivity Sensitivity Sensitivity over Temperature Offset Offset over Temperature ACCELEROMETER NOISE PERFORMANCE Output Noise Noise Density ACCELEROMETER FREQUENCY RESPONSE Sensor Bandwidth Sensor Resonant Frequency ACCELEROMETER SELF-TEST STATE 2 Output Change When Active TEMPERATURE SENSOR Output at 25C Scale Factor ADC INPUT Resolution Integral Nonlinearity Differential Nonlinearity Offset Error Gain Error Input Range Input Capacitance ON-CHIP VOLTAGE REFERENCE Accuracy Reference Temperature Coefficient Output Impedance Conditions Each axis Operable to ~90 degrees 15 degrees, 25C, max filter 30 degrees, 25C, max filter 60 degrees, 25C, max filter 60 degrees, 25C 30 degrees At 25C Each axis At 25C % of full scale X sensor to Y sensor Min 9.9 2037 70 0.25 0.5 1.5 10 50 2048 0.082 2.140 At 25C, 0 g 8151 At 25C, no averaging At 25C, no averaging 372 0.5 0.1 2 2.162 50 8192 0.33 2059 2.5 2.184 8233 Degrees Degrees Degrees Degrees LSB/degrees ppm/C LSB LSB/C g % Degrees % LSB/mg ppm/C LSB LSB/C LSB rms LSB/Hz rms 2250 5.5 Hz kHz 708 1040 LSB 1278 -2.13 LSB LSB/C 12 2 1 4 2 Bits LSB LSB LSB LSB V pF V mV ppm/oC 2.5 20 2.5 -10 +10 40 70 Rev. A | Page 3 of 32 10.1 Unit 22 0.37 0 During acquisition At 25C Max 1.7 At 25C At 25C Typ ADIS16201 Parameter DAC OUTPUT Resolution Relative Accuracy Differential Nonlinearity Offset Error Gain Error Output Range Output Impedance Output Settling Time LOGIC INPUTS Input High Voltage, VINH Input Low Voltage, VINL Logic 1 Input Current, IINH Logic 0 Input Current, IINL Input Capacitance, CIN DIGITAL OUTPUTS Output High Voltage, VOH Output Low Voltage, VOL SLEEP TIMER Timeout Period 3 FLASH MEMORY Endurance 4 Data Retention 5 CONVERSION RATE Minimum Conversion Time Maximum Conversion Time Maximum Throughput Rate Minimum Throughput Rate POWER SUPPLY Operating Voltage Range VDD Power Supply Current Conditions 5 k/100 pF to GND Min Typ Max 12 4 1 5 0.5 0 to 2.5 2 10 For Code 101 to Code 4095 Bits LSB LSB mV % V s 2.0 VIH = VDD VIL = 0 V 0.2 -40 10 ISOURCE = 1.6 mA ISINK = 1.6 mA 0.8 1 -60 2.4 0.5 V V 128 Seconds Cycles Years 244 484 4096 2.066 3.0 Normal mode, SMPL_TIME 0x08 (fs 910 Hz), at 25C Fast mode, SMPL_TIME 0x07 (fs 1024 Hz), at 25C Sleep mode, at 25C Turn-On Time V V A A pF 0.4 20,000 20 TJ = 85C Unit s ms SPS SPS 3.3 11 3.6 14 36 42 500 130 750 V mA mA A ms 1 Guaranteed by iMEMs packaged part testing, design, and/or characterization. Self-test response changes as the square of VDD. 3 Guaranteed by design. 4 Endurance is qualified as per JEDEC Standard 22 Method A117 and measured at -40C, +25C, +85C, and +125C. 2 5 Retention lifetime equivalent at junction temperature (TJ) 55C as per JEDEC Standard 22 Method A117. Retention lifetime decreases with junction temperature. Rev. A | Page 4 of 32 ADIS16201 TIMING SPECIFICATIONS TA = 25C, VDD = 3.3 V, tilt = 0, unless otherwise noted. Table 2. Parameter Description Min 1 fSCLK Fast mode, SMPL_TIME 0x07 (fs 1024 Hz) Normal mode, SMPL_TIME 0x08 (fs 910 Hz) Chip select period, fast mode, SMPL_TIME 0x07 (fs 1024 Hz) Chip select period, normal mode, SMPL_TIME 0x08 (fs 910 Hz) Chip select to clock edge Data output valid after SCLK edge Data input setup time before SCLK rising edge Data input hold time after SCLK rising edge Data output fall time Data output rise time CS high after SCLK edge 0.01 0.01 40 100 48.8 tDATARATE tDATARATE tcs tDAV tDSU tDHD tDF tDR tSFS 1 Typ Max Unit 2.5 1.0 MHz MHz s s ns ns ns ns ns min ns min ns typ 100 24.4 48.8 5 5 12.5 12.5 5 Guaranteed by design, not tested. TIMING DIAGRAMS tDATA RATE tSTALL CS 05462-002 SCLK tSTALL = tDATA RATE - 16/fSCLK Figure 2. SPI Chip Select Timing CS tCS tSFS 1 2 3 4 5 6 15 16 SCLK tDAV MSB DB14 DB13 tDSU DIN W/R DB12 DB11 A4 A3 DB10 DB2 DB1 LSB tDHD A5 A2 D2 Figure 3. SPI Timing (Utilizing SPI Settings Typically Identified as Phase = 1, Polarity = 1) Rev. A | Page 5 of 32 D1 LSB 05462-003 DOUT ADIS16201 ABSOLUTE MAXIMUM RATINGS Table 3. Parameter Acceleration (Any Axis, Unpowered) Acceleration (Any Axis, Powered) VDD to COM Digital Input/Output Voltage to COM Analog Inputs to COM Analog Inputs to COM Operating Temperature Range Storage Temperature Range Rating 3500 g 3500 g -0.3 V to +7.0 V -0.3 V to +5.5 V -0.3 to VDD + 0.3 V -0.3 to VDD + 0.3 V -40C to +125C -65C to +150C Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Table 4. Package Characteristics Package Type 16-Terminal LGA JA 250C/W JC 25C/W ESD CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. Rev. A | Page 6 of 32 Device Weight 0.6 grams ADIS16201 VDD AUX ADC VREF COM PIN CONFIGURATION AND FUNCTION DESCRIPTIONS 13 14 15 16 AUX DAC 12 ADIS16201 NC 11 BOTTOM VIEW (Not to Scale) AUX COM 10 OR 1 SCLK 2 DOUT 3 DIN 4 CS 8 7 6 5 DIO1 DIO0 NC = NO INTERNAL CONNECTION Y SENSOR NC 9 AUX COM RST 05462-004 X SENSOR Figure 4. Pin Configuration Table 5. Pin Function Descriptions Pin No. 1 Mnemonic SCLK Type 1 I 2 DOUT O 3 DIN I 4 5, 6 7, 11 8, 10 9 12 13 14 15 16 CS DIO0, DIO1 NC AUX COM RST AUX DAC VDD AUX ADC VREF COM I I/O - S I O S I O S 1 Description Serial Clock. SCLK provides the serial clock for accessing data from the part and writing serial data to the control registers. Data Out. The data on this pin represents data being read from the control registers and is clocked out on the falling edge of the SCLK. Data In. Data written to the control registers is provided on this input and is clocked in on the rising edge of the SCLK. Chip Select, Active Low. This input frames the serial data transfer. Multifunction Digital I/O Pins. No Connect. Auxiliary Grounds. Connect to GND for proper operation. Reset, Active Low. This input resets the embedded microcontroller to a known state. Auxiliary DAC Analog Voltage Output. +3.3 V Power Supply. Auxiliary ADC Analog Input Voltage. Precision Reference Output. Common. Reference point for all circuitry in the ADIS16201. S = Supply; O = Output; I = Input. Rev. A | Page 7 of 32 ADIS16201 TYPICAL PERFORMANCE CHARACTERISTICS 2.174 120 2.170 100 QUANTITY 2.165 2.157 80 60 2.153 40 2.148 20 3.0 3.1 3.2 3.3 3.4 3.5 3.7 3.6 0 POWER SUPPLY (V) -18 -17 -15 -14 -12 -11 -9 -8 -6 -5 -3 -2 0 2 3 5 6 8 9 11 12 14 15 17 18 2.144 2.9 (mg) Figure 5. Acceleration Sensitivity vs. Power Supply at 25C 05462-008 2.161 05462-005 ACCELERATION SENSITIVITY (LSB/mg) 140 Figure 8. Acceleration Offset Distribution at 25C/3.3 V/0 g 25 20 18 20 16 15 QUANTITY QUANTITY 14 10 12 10 8 6 5 4 -60 -30 0 30 60 90 120 150 (ppm/C) 0 -200 -160 -120 05462-006 -90 -40 0 40 80 120 160 200 (ppm/C) Figure 6. Acceleration Sensitivity Tempco Histogram at 3.3 V Figure 9. Acceleration Offset Tempco Histogram at 3.3 V 2.192 50 40 ACCELERATION OFFSET (LSB) 2.183 2.175 2.166 2.158 2.149 30 20 10 0 -10 -20 -30 2.141 2.132 -60 -40 -20 0 20 40 60 80 100 120 TEMPERATURE (C) 140 Figure 7. Acceleration Sensitivity vs. Temperature at 3.3 V -50 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 POWER SUPPLY (V) Figure 10. Acceleration Offset vs. Supply at 25C Rev. A | Page 8 of 32 3.7 05462-010 -40 05462-007 ACCELERATION SENSITIVITY (LSB/mg) -80 05462-009 2 0 -150 -120 ADIS16201 90 140 80 120 70 100 QUANTITY QUANTITY 60 50 40 80 60 30 40 20 20 10 (Degrees) Figure 11. X-Axis Self-Test Level at 25C/3.3 V 05462-014 05462-011 (g) -1.2 -1.1 -1.0 -0.9 -0.8 -0.7 -0.6 -0.5 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 0 0.18 0.19 0.20 0.21 0.22 0.23 0.24 0.25 0.26 0.27 0.28 0.29 0.30 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 0.40 0.41 0.42 0 Figure 14. Inclination Offset Distribution at 25C/3.3 V/0 g 80 20 18 70 16 60 QUANTITY QUANTITY 14 50 40 30 12 10 8 6 20 4 10 05462-012 0.18 0.19 0.20 0.21 0.22 0.23 0.24 0.25 0.26 0.27 0.28 0.29 0.30 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.38 0.39 0.40 0.41 0.42 (g) 0 -200 -160 -120 -80 -40 0 40 80 120 160 200 (ppm/C) 05462-015 2 0 Figure 15. Inclination Offset Tempco Histogram at 3.3 V Figure 12. Y-Axis Self-Test Level at 25C/3.3 V 10 1200 8 INCLINATION OFFSET (LSB) 800 600 6 4 2 0 -2 -4 -6 400 200 2.9 3.0 3.1 3.2 3.3 3.4 3.5 POWER SUPPLY (V) 3.6 3.7 -10 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 POWER SUPPLY (V) Figure 16. Inclination Offset vs. Supply at 25C Figure 13. Self-Test Shift vs. Supply at 25C Rev. A | Page 9 of 32 3.7 05462-016 -8 05462-013 SELF-TEST SHIFT (LSB) 1000 -3 1 4096 8191 12286 16381 ADC STATE 2 100 1 50 -1 25 -2 0 -3 1 Figure 17. ADC Gain Distribution at 25C/3.3 V 80 40 30 10 0 Figure 18. ADC Offset Distribution at 25C/3.3 V 3 1 -1 Figure 19. Typical ADC Integral Nonlinearity at 25C/3.3 V Rev. A | Page 10 of 32 4096 ADC STATE 8191 12286 Figure 22. DAC Offset Distribution at 25C/3.3 V (mV) 16381 (V/LSB) 05462-020 125 05462-021 3 05462-022 (LSB) 75 606.6 606.9 607.2 607.5 607.8 608.1 608.4 608.7 609.0 609.3 609.6 609.9 610.2 610.5 610.8 611.1 611.4 611.7 612.0 612.3 612.6 612.9 613.2 613.5 617.0 50 QUANTITY 05462-017 607.6 607.8 608.0 608.2 608.4 608.6 608.8 609.0 609.2 609.4 609.6 609.8 610.0 610.2 610.4 610.6 610.8 611.0 611.2 611.4 611.6 611.8 612.0 612.2 612.4 QUANTITY 150 -2.7 -2.4 -2.1 -1.8 -1.5 -1.2 -0.9 -0.6 -0.3 0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.8 0 QUANTITY (mV) 05462-018 -2.4 -2.1 -1.8 -1.5 -1.2 -0.9 -0.6 -0.3 0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 QUANTITY (V/LSB) 05462-019 (LSB) ADIS16201 0 Figure 20. Typical ADC Differential Nonlinearity 120 70 60 100 80 60 20 40 20 0 Figure 21. DAC Gain Distribution at 25C/3.3 V 45 2 40 35 30 25 20 15 -2 10 5 0 ADIS16201 5 3 2 1 120 100 QUANTITY 4 NONLINEARITY (LSB) 140 3.0V/-40C 3.0V/+25C 3.0V/+125C 3.3V /-40C 3.3V/+25C 3.3V/+125C 3.6V/-40C 3.6V/+25C 3.6V/+125C 0 -1 -2 80 60 40 -3 20 -4 1024 1536 2048 2560 3072 3584 4096 DAC STATE 0 (mA) Figure 23. Typical DAC Integral Nonlinearity 05462-026 512 9.4 9.6 9.7 9.9 10.0 10.2 10.3 10.5 10.6 10.8 10.9 11.1 11.2 11.4 11.5 11.7 11.8 12.0 12.1 12.3 12.4 12.6 12.7 12.9 13.0 0 05462-023 -5 Figure 26. Normal Mode Power Supply Current Distribution at 25C/3.3 V 250 140 120 200 QUANTITY QUANTITY 100 150 100 80 60 40 50 20 0 Figure 24. VREF Distribution at 25C/3.3 V 29.0 29.6 30.2 30.8 31.4 32.0 32.6 33.2 33.8 34.4 35.0 35.6 36.2 36.8 37.4 38.0 38.6 39.2 39.8 40.4 41.0 41.6 42.2 42.8 43.4 (mA) 05462-027 (V) 05462-024 2.4975 2.4977 2.4979 2.4981 2.4983 2.4985 2.4987 2.4989 2.4991 2.4993 2.4995 2.4997 2.4999 2.5001 2.5003 2.5005 2.5007 2.5009 2.5011 2.5013 2.5015 2.5017 2.5019 2.5021 2.5023 0 Figure 27. Fast Mode Power Supply Current Distribution at 25C/3.3 V 60 180 160 50 140 QUANTITY 120 30 20 100 80 60 40 10 20 0 370 378 386 394 402 410 418 426 434 442 450 458 466 474 482 490 498 506 514 522 530 538 546 554 562 (A) 05462-028 (C) Figure 25. Temperature Distribution at 25C/3.3 V 0 05462-025 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 QUANTITY 40 Figure 28. Sleep Mode Power Supply Current Distribution at 25C/3.3 V Rev. A | Page 11 of 32 0.0010 0.0008 0.0008 SLEEP MODE CURRENT (A) 0.0010 0.0006 0.0004 0.0002 0.0004 -30 -10 10 30 50 70 90 110 130 TEMPERATURE (C) 150 Figure 29. Sleep Mode Current vs. Temperature at 3.3 V 0 2.9 3.0 3.1 3.2 3.3 3.4 3.5 3.6 SUPPLY VOLTAGE (V) Figure 30. Sleep Mode Current vs. Supply at 25C Rev. A | Page 12 of 32 3.7 05462-030 0 -50 0.0006 0.0002 05462-029 SLEEP MODE CURRENT (A) ADIS16201 ADIS16201 THEORY OF OPERATION The ADIS16201 is a complete dual-axis digital inclinometer/ accelerometer that uses Analog Devices' surface-micromachining process and embedded signal processing to make a functionally complete, low cost dual-axis sensor. The ADIS16201 offers a fully calibrated, dual-axis micromachined sensor element that develops independent analog signals representative of the acceleration levels applied to the part. An on-board precision ADC samples the acceleration signals, along with the power supply voltage, an internal temperature signal, and the auxiliary analog input signal. These signals are then processed and latched into addressable output registers. The serial peripheral interface (SPI) provides convenient, digital access to these registers. One important behavior to observe when using this approach is the fact that the relationship between the acceleration measurements and inclination angle is nonlinear. This nonlinear behavior results in larger quantization error changes as the inclination angle approaches 90. Figure 32 provides a closer look at this behavior by illustrating the increase in step size as the inclination angle estimate increases. Figure 33 offers a direct relationship between the quantization error and the overall inclination angle. OUTPUT INCLINATION ACCELEROMETER OPERATION 0 22.5 45.0 67.5 90.0 TILT (Degrees) Figure 31. Acceleration and Inclination Angle vs. Actual Tilt Angle INCLINATION OUTPUT The acceleration sensor used in the ADIS16201 is a surfacemachined, polysilicon structure built on top of a silicon wafer. Polysilicon springs suspend the structure over the surface of the wafer and provide a resistance against acceleration forces. Acceleration causes a deflection in the differential capacitor structure that includes both fixed plates and plates that are attached to the moving mass. The fixed plates are driven by a set of square waves that are 180o out-of-phase from one another. Acceleration deflects the beam and unbalances the differential capacitor, resulting in an output square wave whose amplitude is proportional to acceleration. Phase sensitive demodulation techniques rectify the signal and determine the direction of the acceleration. The output of the demodulator is amplified, digitized, and processed to remove any process variations and sensitivities to supply variations. 05462-031 ACCELERATION INCLINOMETER OPERATION ACCELERATION 75 80 85 90 TILT (Degrees) The ADIS16201 inclinometer output data is linear with respect to degrees of inclination and is dependent on no forces, other than gravity, acting on the device. The ADIS16201 leverages a simple geometrical relationship to convert its calibrated acceleration measurements into an accurate inclination angle estimate. Figure 31 displays the acceleration measurements associated with each incline angle, along with the resulting inclination angle estimate produced by the ADIS16201. Rev. A | Page 13 of 32 Figure 32. Acceleration and Inclination Angle vs. Actual Tilt Angle 05462-032 In addition, the acceleration signals are further processed to produce inclination angle data for both axes. The inclination angle data represents the tilt away from the ideal plane, which in this case, is normal to the earth's gravitational force. This calculation assumes that no force outside of the earth's gravitational force is acting on the device. ADIS16201 1.5 TEMPERATURE SENSOR The TEMP_OUT control register allows the end user to monitor the internal temperature of the ADIS16201 to an accuracy of 5C. The output data is presented in a straight binary format with a nominal 25C die temperature correlating to a 1278 LSB read through the TEMP_OUT output data register. The temperature scale factor of -2.129 LSB/C allows for a resolution of less than 0.5C in the temperature reading within the output data register. 0.5 0 -0.5 -1.0 -1.5 0 15 30 45 60 75 TILT (Degrees) 90 05462-033 ERROR (Degrees) 1.0 Figure 33. Inclination Quantization Error Rev. A | Page 14 of 32 ADIS16201 BASIC OPERATION The data output register configuration is broken down into three different functions: new data ready bit (ND), alarm indicator (EA), and data bits (D0 to D13). The ND bit is used to determine if a particular register has been updated since the last read command. A Logic Level 1 for ND indicates that unread data is available. When a register is read, this bit is set to a 0 logic level. The alarm indicator provides users with a simple method for passively monitoring a variety of status/alarm conditions and can be used to simplify system-level processing requirements. The ADIS16201 is designed for simple integration into industrial system designs, requiring only a 3.3 V power supply and a 4-wire, industry standard, serial peripheral interface (SPI). Registers that are accessed using the SPI interface facilitate all of the input/output functions on the ADIS16201. Each of these registers is assigned a unique address and data format tailored for its specific function. The SPI port operates in a full duplex mode; data is clocked out of the DOUT pin at the same time command/address data is clocked in through the DIN pin. For more information on basic SPI port operation, see the Applications section. The two acceleration output data registers are 14 bits in length and are formatted as twos complement binary numbers. The rest of the data output registers are 12 bits in length, leaving D12 and D13 as "don't care" bits. The output format for each of these registers, along with their addresses, can be found in Table 7. Each output data register has two different addresses. The first address is for the upper byte, which contains the most significant bits (D8 to D13), ND, and EA data. The second address is for the lower byte, which contains the eight least significant bits (D0 to D7). Reading either of these addresses results in all 16 bits being clocked out on the DOUT line as defined in Table 6 during the next SPI cycle. DATA OUTPUT REGISTER ACCESS For the most basic operation of the ADIS16201, output data registers require only read commands for accessing calibrated sensor data, along with the temperature, power supply, and auxiliary analog input channel data. Each read command requires two full 16-bit cycles. The first cycle is for transmitting the register address, and the second cycle is for reading the data. Table 6 displays the appropriate bit map for the read command. Bit A0 through Bit A5 contain the address of the register being accessed. The appropriate sequencing for each SPI signal (CS, SLCK, DIN, and DOUT) during a read command can be found in Figure 34. CS SCLK ADDRESS DIN IDLE NEXT COMMAND DOUT BASED ON PREVIOUS COMMAND 05462-034 ZERO READ BIT = 0 16-BIT DATA WORD Figure 34. Register Read Command Sequence Table 6. Register Read Command Bit Map DIN W/R1 DOUT ND EA Upper Byte 1 0 A5 A4 A3 A2 A1 A0 x D13 D12 D11 D10 D9 D8 D7 D6 Lower Byte The W/R bit is always 0 for read commands. Rev. A | Page 15 of 32 x x x x x x x D5 D4 D3 D2 D1 D0 ADIS16201 Table 7. Data Output Register Information Name SUPPLY_OUT XACCL_OUT YACCL_OUT AUX_ADC TEMP_OUT XINCL_OUT YINCL_OUT Function Power Supply Data X-Axis Acceleration Data Y-Axis Acceleration Data Auxiliary Analog Input Data Sensor Temperature Data X-Axis Inclination Data Y-Axis Inclination Data Address 0x03, 0x02 0x05, 0x04 0x07, 0x06 0x09, 0x08 0x0B, 0x0A 0x0D, 0x0C 0x0F, 0x0E Resolution (Bits) 12 14 14 12 12 12 12 Data Format Binary Twos complement Twos complement Binary Binary Twos complement Twos complement Table 8. Output Coding Example, XACCL_OUT 1, 2 Acceleration Level +1.7 g +1 g +0.4625 g +0.4625 mg 0g -0.4625 mg -0.4265 g -1 g -1.7 g 1 2 Binary Output 00 1110 0101 1011 00 1000 0111 0010 00 0011 1110 1000 00 0000 0000 0001 00 0000 0000 0000 11 1111 1111 1111 11 1100 0001 1000 11 0111 1000 1110 11 0001 1010 0101 HEX Output 0x0E5B 0x0872 0x03E8 0x0001 0x0000 0x3FFF 0x3C18 0x378E 0x31A5 Two MSBs have been masked off and are not considered in the coding. Nominal sensitivity (2.162 LSB/mg) and zero offset null performance are assumed. Rev. A | Page 16 of 32 Decimal 3675 2162 1000 1 0 -1 -1000 -2162 -3675 Scale Factor (per LSB) 1.22 mV 0.4625 mg 0.4625 mg 0.61 mV -0.47C 0.1 0.1 ADIS16201 PROGRAMMING AND CONTROL CONTROL REGISTER OVERVIEW CONTROL REGISTER ACCESS The ADIS16201 offers many programmable features that are controlled by writing commands to the appropriate control registers using the SPI. For added system flexibility and programmability, the following sections describe these controls and specify the 28 digital control registers that are available using the SPI interface. A high level listing of these registers is given within Table 9. The following sections expand upon the functionality of each of these control registers, providing for the full clarification of the behavior of each of the control registers. Available control modes for the device include selectable sample rates for reading the seven output vectors, configurable output data, alarm settings, control of the on-board 12-bit auxiliary DAC, handling of the two general-purpose I/O lines, facilitation of the sleep mode, enabling the self-test mode, and other miscellaneous control functions. The control registers within the ADIS16201 are based upon a 16-bit/2-byte format, and they are accessed via the SPI. The SPI operates in full duplex mode with the data clocked out of the DOUT pin at the same time data is clocked in through the DIN pin. All commands written to the ASIS16201 are categorized as write commands or read commands. All write commands are self-contained and take place within a single cycle. Each read command requires two cycles to complete; the first cycle is for transmitting the register address, and the second cycle is for reading the data. During the second cycle, when the data out line is active, the data in line is used to receive the next sequential command. This allows for overlapping the commands. For more information on basic SPI port operation, see the Applications section. The conversion process is repeated continually, providing for continuous update of the seven output registers. The new data ready bit (ND) flags bits common to all seven output registers, allowing the completion of the conversion process to be tracked via the SPI. As an alternative, the digital I/O lines can be configured through software control to create a data-ready hardware function that can signal the completion of the conversion process. Two independent alarms provide the ability to monitor any one of the seven output registers. They can be configured to report an alarm condition on either fixed thresholds or rates of change. The alarm conditions are monitored through the SPI. In addition, the user can configure the digital I/O lines through software control to create an alarm function that allows for monitoring of the alarm conditions through hardware. The seven output signals noted above are calibrated independently at the factory, delivering a high degree of accuracy. In addition, the user has access to independent offset and scale factors for each of the two acceleration and inclination output vectors. This allows independent scaling and level adjustment control of any one these four registers prior to the values being read via the SPI. In turn, field level calibrations can be implemented within the sensor itself using these offset and scale variables. System level commands provided within the sensor include automatic zeroing of the four outputs using a single null command via the SPI. In addition, the original factory calibration settings can be recovered at any point, using a simple factory reset command. The read and write commands are identified through the most significant bit (MSB), B15, of the received data. Write a 1 to B15 to indicate a write command. Write a 0 to B15 to indicate a read command. Bit B13 through Bit B8 contain the address of the control register that is being accessed. The remaining eight bits of the write command contain the data that is being written into the part, whereas the remaining eight bits of the read command contain don't care levels. Given that the data within the write command is eight bits in length, the 8-bit data format is the default byte size. A write command operates on a single chip select cycle, as shown in Figure 35. The read command operates on a 2-chip select cycle basis, as seen in Figure 34. All 64 bytes of register space are accessed using the 6-bit address. Data written into the device is one byte at a time with the address of each byte being explicitly called out in the write command. Conversely, data being read from the device consists of two, back-to-back, 8-bit variables being sent out, with the first byte out corresponding to the upper address (odd number address) and the second byte relating to the next lower address space (even number address). For example, a data read of Address 03h results in the data from Address 03h being fed out followed by data from Address 02h. Likewise, a data read of Address 02h results in the same data stream being output from the device. The ADIS16201 is a flash-based device with the nonvolatile functional registers implemented as flash registers. Take into account the endurance limitation of 20,000 writes when considering the system-level integration of these devices. The nonvolatile column in Table 9 indicates which registers are recovered upon power-up. The user must instigate a manual flash update command (using the command register) in order to store the nonvolatile data registers, once they are configured properly. When performing a manual flash update command, the user needs to ensure that the power supply remains within limits for a minimum of 50 s after the write is initiated. This ensures a successful write of the nonvolatile data. Rev. A | Page 17 of 32 ADIS16201 Table 9. Control Register Mapping Register Name Type Nonvolatile SUPPLY_OUT XACCL_OUT YACCL_OUT AUX_ADC TEMP_OUT XINCL_OUT YINCL_OUT XACCL_ OFF YACCL_ OFF XACCL_ SCALE YACCL_ SCALE XINCL_OFF YINCL_ OFF XINCL_SCALE YINCL_ SCALE ALM_MAG1 ALM_MAG2 ALM_SMPL1 ALM_SMPL2 ALM_CTRL R R R R R R R R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W X X X X X X X X X X X X X AUX_DAC GPIO_CTRL MSC_CTRL SMPL_PRD AVG_CNT PWR_MDE STATUS COMMAND R/W R/W R/W R/W R/W R/W R W Address 0x00 to 0x01 0x02 0x04 0x06 0x08 0x0A 0x0C 0x0E 0x10 0x12 0x14 0x16 0x18 0x1A 0x1C 0x1E 0x20 0x22 0x24 0x26 0x28 0x2A to 0x2F 0x30 0x32 0x34 0x36 0x38 0x3A 0x3C 0x3E X X Bytes 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 6 2 2 2 2 2 2 2 2 Function Reserved Power supply output data X-axis acceleration output data Y-axis acceleration output data Auxiliary ADC data Temperature output data X-axis inclination output data Y-axis inclination output data X-axis acceleration offset factor Y-axis acceleration offset factor X-axis acceleration scale factor Y-axis acceleration scale factor X-axis inclination offset factor Y-axis inclination offset factor X-axis inclination scale factor Y-axis inclination scale factor Alarm 1 amplitude threshold Alarm 2 amplitude threshold Alarm 1 sample period Alarm 2 sample period Alarm source control register Reserved Auxiliary DAC data Auxiliary digital I/O control register Miscellaneous control register ADC sample period control Defines number of samples used by moving average filter Counter used to determine length of power-down mode System status register System command register Table 10. Register Write Command Bit Map W/R 0 Upper Byte A5 A4 A3 A2 A1 A0 D7 D6 Lower Byte D5 CS SCLK DIN ADDRESS ZERO WRITE BIT = 1 DATA 05462-035 DIN Figure 35. Control Register Write Command Sequence of SPI Signals Rev. A | Page 18 of 32 D4 D3 D2 D1 D0 ADIS16201 CONTROL REGISTER DETAILS The control registers in the ADIS16201 are 16 bits in length. Each of them has been assigned an address for their upper byte and lower byte. The bit map of each control register uses the numerical assignments that are displayed in the following table. MSB LSB 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 The upper byte consists of Bit 8 to Bit 15, and the lower byte consists of Bit 0 to Bit 7. Each of the following sections provides a description of each register that includes purpose, relevant scaling information, bit maps, addresses, and default values. CALIBRATION The ADIS16201 outputs are precalibrated at the factory, providing a high degree of accuracy and simpler system implementation. In addition, for system or field updates, the device has eight control registers associated with calibrating the acceleration and inclination output data (see the Calibration Register Definitions section). Each of these registers has read/write capability and is 16 bits (2 bytes) in length. All calibration registers are 12 bits in length, with the exception of the inclination offset registers, which are 9 bits in length. All data values are aligned to the LSB. The OFFSET registers all utilize the twos complement format allowing for both positive and negative offsets. All scale registers utilize the straight binary format. The data within these eight calibration registers is utilized in offsetting and scaling of the output data registers according to the following relationship: Output = A x ( x + C ) where: x represents the raw data prior to calibration. C is the offset. A is the scalar. Output represents the output data register where the resultant data is stored. All four inertial sensor outputs (X and Y acceleration, X and Y inclination) have their own independent set of calibration registers. Simple access to these registers enables field calibration to correct for in-system error sources. In particular, the offset control registers allow the user to reset to 0/0 mg reference point for the device. This is particularly important when considering the stack-up of the tolerances in mounting the ADIS16201 to a printed circuit board (PCB), the PCB to an enclosure, the enclosure mounted to the chassis of a piece of equipment, and so on. The result is that the ADIS16201 mechanical reference can be offset several degrees from that of the end equipment mechanical reference, resulting in an accumulation of offset errors in the inclination and acceleration data output registers. The offset registers provide a convenient tool for managing these types of errors. A global command is implemented within the ADIS16201 to simplify the loading of the offsets. Once the end piece of equipment is leveled to its desired reference point, a null command can be sent to the ADIS16201 via the command control register, which zeros the two acceleration and the two inclination output data registers. This command loads all four offset registers with the inverse of their contents at the time of the null command. Consequently, on the next reading of the seven output data registers, the two acceleration and two inclination output data registers should be reset to mid-scale (neglecting noise and repeatability limitations). It is suggested that when the null command is implemented, the AVG_CNT control register be set to 08h in order to maximize the filtering and reduce the effects of noise in determining the values to be loaded into the offset control registers. Optionally, the user can manually load each of the eight calibration registers via the SPI in order to calibrate the end system. This is applicable when the user plans to adjust the scale factors, thus requiring an external stimulus to excite the ADIS16201. CALIBRATION REGISTER DEFINITIONS XACCL_OFF Register Definition Address 0x11, 0x10 1 Scale1 0.4624 mg Default 0x0000 Format Twos complement Access R/W Scale is the weight of each LSB. The XACCL_OFF register is the user-controlled register for calibrating system-level acceleration offset errors. For the X-axis acceleration, it represents the C variable in the calibration equation. The maximum calibration range is +0.945 g, or +2047/-2048 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Table 11. XACCL_OFF Bit Designations Bit 15:12 11:0 Rev. A | Page 19 of 32 Description Not used Data bits ADIS16201 XINCL_OFF Register Definition XACCL_SCALE Register Definition Address 0x15, 0x14 1 1 Scale 0.0488% Default 0x0800 Format Binary Access R/W Scale is the weight of each LSB. 1 The XACCL_SCALE register is the user-controlled register for calibrating system-level acceleration sensitivity errors. For the X-axis acceleration, it represents the A variable in the calibration equation. This register offers a sensitivity calibration range of 0 to 2, or 0 to 4095 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Table 12. XACCL_SCALE Bit Designations Bit 15:12 11:0 1 Default 0x0000 Format Twos complement Default 0x0000 Format Twos complement Access R/W Scale is the weight of each LSB. The XINCL_OFF register is the user-controlled register for calibrating system-level inclination offset errors. For the X-axis inclination, it represents the C variable in the calibration equation. The maximum calibration range is +25.5 or +255/-256 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Bit 15:9 8:0 YACCL_OFF Register Definition Scale1 0.4624 mg Scale1 0.1 Table 15. XINCL_OFF Bit Designations Description Not used Data bits Address 0x13, 0x12 Address 0x19, 0x18 R/W Both XINCL_SCALE Register Definition Address 0x1D, 0x1C 1 Scale is the weight of each LSB. Description Not used Data bits Scale1 0.0488% Default 0x0800 Format Binary Access R/W Scale is the weight of each LSB. The YACCL_OFF register is the user-controlled register for calibrating system-level acceleration offset errors. For the Y-axis acceleration, it represents the C variable in the calibration equation. The maximum calibration range is +0.945 g, or +2047/-2048 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. The XINCL_SCALE register is the user-controlled register for calibrating system-level inclination sensitivity errors. For the Xaxis inclination, it represents the A variable in the calibration equation. The calibration range is from 0 to 2, or 0 to 4095 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Table 13. YACCL_OFF Bit Designations Table 16. XINCL_SCALE Bit Designations Bit 15:12 11:0 Bit 15:12 11:0 Description Not used Data bits YINCL_OFF Register Definition YACCL_SCALE Register Definition Address 0x17, 0x16 1 Scale1 0.0488% Default 0x0800 Format Binary Access R/W Scale is the weight of each LSB. Table 14. YACCL_SCALE Bit Designations Description Not used Data bits Address 0x1B, 0x1A 1 The YACCL_SCALE register is the user-controlled register for calibrating system-level acceleration sensitivity errors. For the Y-axis acceleration, it represents the A variable in the calibration equation. This register offers a sensitivity calibration range of 0 to 2, or 0 to 4095 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Bit 15:12 11:0 Description Not used Data bits Scale1 0.1 Default 0x0000 Format Twos complement Access R/W Scale is the weight of each LSB. The YINCL_OFF register is the user-controlled register for calibrating system-level inclination offset errors. For the Y-axis inclination, it represents the C variable in the calibration equation. The maximum calibration range is +25.5 or +255/ -256 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Table 17. YINCL_OFF Bit Designations Bit 15:9 8:0 Rev. A | Page 20 of 32 Description Not used Data bits ADIS16201 YINCL_SCALE Register Definition Scale1 0.0488% Address 0x1F, 0x1E 1 Default 0x0800 Format Binary Access R/W Scale is the weight of each LSB. The YINCL_SCALE register is the user-controlled register for calibrating system-level inclination sensitivity errors. For the Y-axis inclination, it represents the A variable in the calibration equation. The calibration range is from 0 to 2, or 0 to 4095 codes, assuming nominal sensor sensitivity. The contents of this register are nonvolatile. Table 18. YINCL_SCALE Bit Designations Bit 15:12 11:0 Description Not used Data bits ALARMS The ADIS16201 contains two independent alarm functions that are referred to as Alarm 1 and Alarm 2. The Alarm 1 function is managed by the ALM_MAG1 and ALM_SMPL1 control registers. The Alarm 2 function is managed by the ALM_MAG2 and ALM_SMPL2 control registers. Both the Alarm 1 and Alarm 2 functions share the ALM_CTRL register. For simplicity, the following text references the Alarm 1 functionality only. The 16-bit ALM_CTRL register serves three distinct roles in controlling the Alarm 1 function. First, it is used to enable the overall Alarm 1 function and select the output data variable that is to be monitored for the alarm condition. Second, it is used to select whether the Alarm 1 function is based upon a predefined threshold (THR) level or a predefined rate-of-change (ROC) slope. Third, the ALM_CTRL register can be used in setting up one of the two general-purpose input/output lines (GPIOs) to serve as a hardware output that indicates when an alarm condition has occurred. Enabling the I/O alarm function, setting its polarity, and controlling its operation are accomplished using this register. Note that when enabled, the hardware output indicator serves both the Alarm 1 and Alarm 2 functions and cannot be used to differentiate between one alarm condition and the other. It is simply used to indicate that an alarm is active and that the user should poll the device via the SPI to determine the source of the alarm condition (see the STATUS Register Definition section). Because the ALM_CTRL, MSC_CTRL, and GPIO_CTRL control registers can influence the same GPIO pins, a priority level has been established to avoid conflicting assignments of the two GPIO pins. This priority level is defined as MSC_CTRL, which has precedence over ALM_CTRL, which has precedence over GPIO_CTRL. The ALM_MAG1 control register used in controlling the Alarm 1 function has two roles. The first role is to store the value with which the output data variable is compared to discern if an alarm condition exists or not. The second role is to identify whether the alarm should be active for excursions above or below the alarm limit. If 1 is written to the GT1 bit of the ALM_MAG1 control register, the alarm is active for excursions extending above a given limit. If 0 is written to the GT1 bit, the alarm is active for excursions dropping below the given limit. The comparison value contained within the ALM_MAG1 control register is located within the lower 14 bits. The format utilized for this 14-bit value should match that of the output data register that is being monitored for the alarm condition. For instance, if the YINCL_OUT output data register is being monitored by Alarm 1, then the 14-bit value within the ALM_MAG1 control register takes on a twos complement format with each LSB equating to nominal 0.1 (assumes unity scale and zero offset factors). The ALM_MAG value is compared against the instantaneous value of the parameter being monitored. Use caution when monitoring the temperature output register for the alarm conditions. Here, the negative temperature scale factor results in the greater than and less than selections requiring reverse logic. When the THR function is enabled, the output data variable is compared against the ALM_MAG1 level. When the ROC function is enabled, the comparison of the output data variable is against the ALM_MAG1 level averaged over the number of samples, as identified in the ALM_SMPL1 control register. This acts to create a comparison of ( units/ time) or the derivative of the output data variable against a predefined slope. Rev. A | Page 21 of 32 ADIS16201 The versatility built into the alarm function is intended to allow the user to adapt to a number of different applications. For example, in the case of monitoring a twos complement variable, the GT1 bit within the ALM_MAG1 control register can allow for the detection of negative excursions below a fixed level. In addition, the Alarm 1 and Alarm 2 functions can be set to monitor the same variable that allows the user to discern if an output variable remains within a predefined window. The ALM_SMPL1 register contains the sample period information for Alarm 1, when it is set for rate-of-change alarm monitoring. The rate-of-change alarm function averages the change in the output variable over the specified number of samples and compares this change directly to the values specified in the ALM_MAG1 register. The contents of this register are nonvolatile. Other options include the ROC function that can be used in monitoring high frequency shock levels in the acceleration outputs or slowly changing outputs in the inclination level over a period of a minute or more. With the addition of the alarm hardware functionality, the ADIS16201 can be left to run independently of the main processor and interrupt the system only when an alarm condition occurs. Conversely, the alarm condition can be monitored through the routine polling of any one of the seven data output registers. Bit 15:8 7:0 Table 20. ALM_SMPL1 Bit Designations ALM_MAG2 Register Definition Address 0x23, 0x22 1 Note that the alarm functions work from instantaneous data and not averaged data that can be present when the AVG_CNT register is not set to 0. The alarm hardware output indicator is not latched but tracks the actual alarm conditions in real time. ALM_MAG1 Register Definition Address 0x21, 0x20 1 Default1 0x0000 Format N/A Bit 15 Table 19. ALM_MAG1 Bit Designations 14 13:0 ALM_SMPL1 Register Definition Address 0x25, 0x24 1 Default1 0x0000 Format Binary Default is valid only until the first register write cycle. Access R/W Access R/W Table 21. ALM_MAG2 Bit Designations 14 13:0 Description Greater than active alarm bit. 1: Alarm is active for an output greater than Alarm Magnitude 1 register setting. 0: Alarm is active for an output less than Alarm Magnitude 1 register setting. Not used. Data bits. This number can be either twos complement or straight binary. The format is set by the value being monitored by this function. Format N/A The ALM_MAG2 register contains the threshold level for Alarm 2. The contents of this register are nonvolatile. Default is valid only until the first register write cycle. Bit 15 Default1 0x0000 Default is valid only until the first register write cycle. Access R/W The ALM_MAG1 register contains the threshold level for Alarm 1. The contents of this register are nonvolatile. Description Not used Data bits Description Greater than active alarm bit. 1: Alarm is active for an output greater than Alarm Magnitude 2 register setting. 0: Alarm is active for an output less than Alarm Magnitude 2 register setting. Not used. Data bits. This number can be either twos complement or straight binary. The format is set by the value being monitored by this function. ALM_SMPL2 Register Definition Address 0x27, 0x26 1 Default1 0x0000 Format Binary Access R/W Default is valid only until the first register write cycle. The ALM_SMPL2 register contains the sample period information for Alarm 2, when it is set for rate-of-change alarm monitoring. The rate-of-change alarm function averages the change in the output variable over the specified number of samples and compares this change directly to the values specified in the ALM_MAG1 register. The contents of this register are nonvolatile. Table 22. ALM_SMPL2 Bit Designations Bit 15:8 7:0 Rev. A | Page 22 of 32 Description Not used Data bits ADIS16201 ALM_CTRL Register Definition 1 Default1 0x0000 Format N/A SAMPLE PERIOD CONTROL Access R/W Default is valid only until the first register write cycle. The ALM_CTRL register contains the alarm control variables. Bit 15 Value 14:12 000 001 010 011 100 101 110 111 11 10:8 000 001 010 011 100 101 110 111 7:3 2 1 0 Description Rate of change (ROC) enable for Alarm 2. 1: ROC is active. 0: ROC is inactive. Alarm 2 source selection. Alarm disable. Alarm source: power supply output. Alarm source: X-acceleration output. Alarm source: Y-acceleration output. Alarm source: auxiliary ADC output. Alarm source: temperature sensor output. Alarm source: X-inclination output. Alarm source: Y-inclination output. Rate of change (ROC) enable for Alarm 1. 1: ROC is active. 0: ROC is inactive. Alarm 1 source selection. Alarm disable. Alarm source: power supply output. Alarm source: X-acceleration output. Alarm source: Y-acceleration output. Alarm source: auxiliary ADC output. Alarm source: temperature sensor output. Alarm source: X-inclination output. Alarm source: Y-inclination output. Not used. Alarm output enable. 1: Alarm output enabled. 0: Alarm output disabled. Alarm output polarity. 1: Active high. 0: Active low. Alarm output line select. 1: DIO1. 0: DIO0. Note that the sample period given is defined as the cumulative time required to sample, process, and update all seven data output variables. The seven data output variables are sampled as a group and in unison with one another. Whatever update rate is selected for one signal, all seven output data variables are updated at the same rate whether they are monitored via the SPI or not. For a sample period setting of less than 1098.9 s (SMPL_RATE 0x07), the overall power dissipation in the part rises by approximately 300%. The default setting for the SMPL_RATE register is 0x04 at initial power-up, thus allowing for the maximum SPI clock rate of 2.5 MHz. 256 192 SMPL_PRD VALUE Table 23. ALM_CTRL Bit Designations The seven output data variables within the ADIS16201 are sampled and updated at a rate based upon the SMPL_PRD control register. The sample period can be precisely controlled over more than a 3-decade range using a time base with two settings and a 7-bit binary count. The use of a time base that varies with a ratio of 1:31 allows for a more optimal resolution in the sample period than a straight binary counter. This is reflected in Figure 36, where the frequency is presented on a logarithmic scale. The choice of the two time base settings results in making the sample period setting more linear vs. the logarithmic frequency scale. 128 64 0 1 10 100 1k FREQUENCY (Hz) Figure 36. SMPL_PRD Values vs. Sample Frequency Rev. A | Page 23 of 32 10k 05462-036 Address 0x29, 0x28 ADIS16201 SMPL_PRD Register Definition Address 0x37, 0x36 Default 0x0004 Format N/A Access R/W Default is valid only until the first register write cycle. The data within this register is nonvolatile, allowing for data recovery upon reset. The initial value is set to 0x04 upon initial power-up, allowing for a sample period of 610 s. The more taps, the more poles, thus the steeper the slope of the roll-off. Use caution with this filter mechanism because the amplitudes of the sideband peaks within the stop band are not reduced with an increasing number of taps, potentially allowing for high frequency components to leak through. Sample frequency response plots for the moving average filter, utilizing various numbers of taps, are detailed in Figure 37. H(f) 1.0 Table 24. SMPL_PRD Bit Descriptions 7 6:0 Description Not used. ADC time base control. The MSB and TMBS set the time base of the acquisition system to 122.1 s when SR7 = 0 vs. 3.784 ms when SR7 = 1. ADC Sample Period Count. The lower 7 bits, SP6 to SP0, represent a binary count that, when added to one and then multiplied by the time base, results in the combined sample period of the ADC. (Combined sample period being the period required to sample and update all seven data outputs.) Minimum setting for the lower 7 bits, SP6 to SP0, is 0x01. The overall acquisition time can be varied from 244.2 s to 15.51 ms in 122.1 s increments for TMBS = 0 and from 7.57 ms to 481 ms in 3.784 ms increments for TMBS = 1. This equates to the sample rate varying from 4096 SPS to 64.5 SPS for TMBS = 0 and from 132 SPS to 2.08 SPS for TMBS = 1. FILTERING CONTROL The ADIS16201 has the ability to perform basic filtering on the seven output data variables through the AVG_CNT control register. The filtering performed is that of a low-pass, moving average filter. The size of the data being averaged (number of filter taps) is determined through the AVG_CNT control register. The filtering applied through the AVG_CNT control register is applied to all seven data output variables concurrently and, thus, one output variable cannot be filtered differently from another. The number of taps (N) within the moving average filter is calculated as At the other extreme, when AVG_CNT is set to its maximum setting of 08h, N increases to 256, effectively reducing the apparent bandwidth by 256. Note that the contribution from each tap is set to 1/(N) allowing for unity gain in the filter response. The frequency response of the moving average filter is given as: sin( x N x f x t s ) 0 -0.5 0 0.1 0.2 0.3 0.4 f/fs 0.5 FREQUENCY (Hz) Figure 37. Number of Taps vs. Sample Frequency Response AVG_CNT Register Definition Address 0x39, 0x38 1 Default1 0x0004 Format Binary Access R/W Default is valid only until the first register write cycle. The AVG_CNT register contains information that represents the number of averages to be applied to the output data. The number of averages can be calculated by powers of 2. For example, the default value of the register, 4, would result in 16 averages applied to the output data. The number of averages can be set to 1, 2, 4, 8, 16, 32, 64, 128, and 256. Table 25. AVG_CNT Bit Description Bit 15:4 Description Not used Data bits (maximum = 1000, or a decimal value of 8) POWER-DOWN CONTROL where AVG_CNT is shown as a decimal value. With AVG_CNT set to 00h, N is reduced to 1, which effectively disables the moving average filter. H( f ) = 0.5 N = 16 3:0 N = 2 AVG _ CNT N=2 N=4 NUMBER OF TAPS Bit 15:8 05462-037 1 1 The ADIS16201 has the ability to power down for user-defined amounts of time, using the PWR_MDE control register. The amount of time specified by the PWR_MDE control register is equal to the binary count of the 8-bit control word multiplied by 0.5 seconds. Therefore, the 255 codes cover an overall shutdown time period of 127.5 seconds. The PWR_MDE register is volatile and is set to 0 upon both initial power-up and subsequent wakeups from the power-down period. By setting the PWR_MDE control register to a non-zero state, the ADIS16201 automatically powers down once the next sample period is completed and the seven data output registers are updated. N sin( x f x t s ) Rev. A | Page 24 of 32 ADIS16201 Once the ADIS16201 is placed into the power-down mode, it can only return to normal operation by timing out, a reset command (using the RST hardware control line), or by cycling the power applied to the part. Once awake, the seven data output registers can be scanned to determine what the state of the output registers were prior to powering down. Once the data is recovered, the device can be powered down again by writing a non-zero value to the PWR_MDE control register and starting the process over. Once the power-down time is complete, the recovery time for the ADIS16201 is approximately 2 ms. This recovery time is implemented within the device to allow for recovery of the ADC prior to performing the next data conversion. Note that the ND data bit within the seven data output control registers is cleared when the ADIS16201 is powered down. Likewise, the new data hardware I/O line is placed into an inactive state prior to being powered down. The DAC is placed into a power-down mode as well, which results in the DAC output dropping to 0 V during the power-down period. All control register settings are retained while powered down with the exception of the PWR_MDE control register, which is reset to 0 prior to power-down. STATUS Register Definition Address 0x3D, 0x3C 1 1 Default1 0x0000 Format Binary Access R/W Table 27. STATUS Bit Descriptions Bit 15:10 9 8 7:4 3 Default is valid only until the first register write cycle. Table 26. PWR_MDE Bit Descriptions Bit 15:8 7:0 Description Not used Data bits STATUS FEEDBACK The status control register within the ADIS16201 is utilized in determining the present state of the device. The ability to monitor the device becomes necessary when and if the ADIS16201 has registered an alarm or error condition as indicated by the "alarm enable" (14) within the seven output data registers. The 16-bit status register is broken into two bytes. The three lower bits of the lower data byte are used to indicate which error condition exists, while the two lower bits of the upper data byte are utilized in indicating which alarm condition exists. Access Read only The STATUS control register contains the alarm/error flags that indicate abnormal operating conditions. See Table 27 for each status bit definition. All flags are cleared upon the reading of the status register. The flags are set on a continuing basis as long as the error or alarm conditions persist. 2 The power-down period is determined by multiplying the binary value represented by the data bits times the constant 0.5 seconds. This results in a variable power-down period of 0.5 seconds to 127.5 seconds with 0.5 seconds resolution in the setting. A setting of 0 disables the power-down mode, whereas any non-zero entry places the device in the power-down mode at the next update of the data output registers. The power-down register is volatile and is set to all 0s upon initial power-up and recovery from the power-down mode. Format N/A Default is valid only until the first register write cycle. PWR_MDE Register Definition Address 0x3B, 0x3A Default1 0x0000 1 0 Description Not used. Alarm 2 status. 1: Active 0: Normal mode Alarm 1 status. 1: Active 0: Normal mode Not used. SPI communications failure. 1: Error condition 0: Normal mode Control register update failed. 1: Error condition 0: Normal mode Power supply above 3.625 V. 1: Error condition 0: Normal mode Power supply below 2.975 V. 1: Error condition 0: Normal mode COMMAND CONTROL The COMMAND control register is utilized in sending global commands to the ADIS16201 device. There are four separate commands that act as global commands in the controlling of the ADIS16201 operation. Any one of the four commands can be implemented by writing 1 to its corresponding bit location. The command control register has write-only capability and is volatile. Table 28 describes each of these global commands. COMMAND Register Definition Address 0x3F, 0x3E 1 Default1 0x0000 Format N/A Default is valid only until the first register write cycle. Rev. A | Page 25 of 32 Access Write only ADIS16201 Table 28. COMMAND Bit Descriptions Bit 15:8 7 6:4 3 2 1 0 Description Not used. Software Reset Command. Allows for resetting of the device via the SPI. Not used. Manual Flash Update Command. This command is utilized in updating all of the nonvolatile registers to flash. Once the command is initiated, the supply voltage, VDD, must remain within specified limits for 50 ms to assure proper update of the nonvolatile registers to flash. Auxiliary DAC Latch Command. This command acts to latch the AUX_DAC control register data into the auxiliary DAC upon receipt of the command. This allows for sequential loading of the upper and lower AUX_DAC data bytes via the SPI without having the auxiliary DAC transition into unwanted, intermediate states based upon the individual AUX_DAC data bytes. Once the two bytes of AUX_DAC are loaded, the DAC latch command is initiated to move the data into the auxiliary DAC itself. Factory Reset Command. Allows the user to reset all four system level offset registers and all four system level scale registers to the nominal settings (000h and 800h, respectively) upon receipt of command. Data within the moving average filters will likewise be reset. As the manual flash command identified below, this command stores all of the nonvolatile registers to flash. Once the command is initiated, the supply voltage, VDD, must remain within specified limits for 50 ms to assure proper update of the nonvolatile registers to flash. Null Command. Loads the X/Y inclination offset as well as the X/Y acceleration offset registers with values that zero out the inclination and acceleration outputs. Useful as a single command to simultaneously zero both inclination and acceleration outputs. As the manual flash command identified below, this command stores all of the nonvolatile registers to flash. Once the command is initiated, the supply voltage, VDD, must remain within specified limits for 50 ms to assure proper update of the nonvolatile registers to flash. MISCELLANEOUS CONTROL REGISTER The MSC_CTRL control register within the ADIS16201 provides control of two miscellaneous functions: the data-ready hardware I/O function and the self-test function. The bits to control these two functions are shown in Table 29. The operation of the data-ready hardware I/O function is very similar to the alarm hardware I/O function (controlled through the ALM_CTRL control register). In this case, the MSC_CNTRL register can be used in setting up one of the two GPIO pins to serve as the hardware output pin that indicates when the sampling, conversion, and processing of the seven data output variables has been completed. This register provides the ability to enable the data-ready hardware function and establish its polarity. The data-ready hardware I/O pin is reset automatically to an inactive state part way through the next conversion cycle, resulting in a pulse train with a duty cycle varying from ~15% to 35%, depending upon the sample period setting. Upon completion of the next sample/conversion/processing cycle, the data ready hardware I/O line is reasserted. The MSC_CTRL, ALM_CTRL, and GPIO_CTRL control registers can influence the same GPIO pins. A priority level has been established to avoid conflicting assignments of the two GPIO pins. This priority level is defined as MSC_CTRL and has precedence over ALM_CTRL, which has precedence over GPIO_CTRL. The self-test enable bit allows the user to place the ADIS16201 into a diagnostics mode for purposes of verifying the base sensor's operation. When this bit is set high, an electrostatic force is generated internally to the sensor. The resulting movement within the sensor allows the end user to test if the accelerometer is functional. Typical change in the output is 328 mg (corresponding to 708 LSB). Once the self-test enable bit is returned to a low state, normal operation is resumed. MSC_CTRL Register Definition Address 0x35, 0x34 1 Default1 0x0000 Format N/A Access R/W Default is valid only until the first register write cycle. The 16-bit miscellaneous control register is used in the controlling of the self-test and data-ready hardware functions. This includes turning on and off the self-test function, as well as enabling and configuring the data-ready function. For the dataready function, the written values are nonvolatile, allowing for data recovery upon reset. The self-test data is volatile and is set to 0s upon reset. This register has read/write capability. Table 29. MSC_CTRL Bit Descriptions Bit 15:9 8 7:3 2 1 0 Rev. A | Page 26 of 32 Description Not used. Self-test enable. 1: ST enabled 0: ST disabled Not used. Data-ready enable. 1: DR enabled 0: DR disabled Data-ready polarity. 1: Active high 0: Active low Data-ready line select. 1: DIO1 0: DIO0 ADIS16201 PERIPHERALS AUXILIARY ADC FUNCTION AUXILIARY DAC FUNCTION The auxiliary ADC function integrates a standard 12-bit ADC into the ADIS16201 to digitize other system-level analog signals. The output of the ADC can be monitored through the AUX_ADC control register, as defined in Table 6 and Table 7. The ADC consists of a 12-bit successive approximation converter. The output data is presented in straight binary format, with the full scale range extending from 0 V to VREF. A high precision, low drift, factory-calibrated 2.5 V reference is also provided. The auxiliary DAC function integrates a standard 12-bit DAC into the ADIS16201. The DAC output is buffered and fed offchip to allow for the control of miscellaneous system-level functions. Data is downloaded through the writing of two adjacent data bytes, as defined in its register definition. To prevent the DAC from transitioning through inadvertent states during data downloads, a single command is used to simultaneously latch both data bytes into the DAC after they have been written into the AUX_DAC control register. This command is implemented by writing 1 to Bit 2 of the command control register, which, once received, results in the DAC output transitioning to the desired state. Figure 38 shows the equivalent circuit of the analog input structure of the ADC. The input capacitor, C1, is typically 4 pF and can be attributed to parasitic package capacitance. The two diodes provide ESD protection for the analog input. Care must be taken to ensure that the analog input signals never exceed the supply rails by more than 300 mV. This would cause these diodes to become forward-biased and start conducting. They can handle 10 mA without causing irreversible damage to the part. The resistor is a lumped component that represents the on resistance of the switches. The value of this resistance is typically 100 . Capacitor C2 represents the ADC sampling capacitor and is typically 16 pF. VDD C1 D R1 C2 AUX_DAC Register Definition 05462-038 D The DAC output provides an output range of 0 V to 2.5 V. The DAC output buffer features a true rail-to-rail output stage. This means that, unloaded, the output is capable of reaching within 5 mV of ground. Moreover, the DAC's linearity performance (when driving a 5 k resistive load to ground) is good through the full transfer function, except for Code 0 to Code 100. Linearity degradation near ground is caused by saturation of the output amplifier. As the output is forced to sink more current, the nonlinear region at the bottom of the transfer function becomes larger. Larger current demands can significantly limit output voltage swing. Address 0x31, 0x30 Figure 38. Equivalent Analog Input Circuit Conversion Phase: Switch Open Track Phase: Switch Closed 1 For ac applications, removing high frequency components from the analog input signal is recommended through the use of an RC low-pass filter on the relevant analog input pins. In applications where harmonic distortion and signal-to-noise ratio are critical, the analog input should be driven from a low impedance source. Large source impedances significantly affect the ac performance of the ADC. This can necessitate the use of an input buffer amplifier. When no input amplifier is used to drive the analog input, the source impedance should be limited to values lower than 1 k. The maximum source impedance depends on the amount of total harmonic distortion (THD) that can be tolerated. Default1 0x0000 Format Binary Access R/W Default is valid only until the first register write cycle. The AUX_DAC register controls the ADIS16201's DAC function. The data bits provide a 12-bit binary format number with 0 representing 0 V and 0x0FFFh representing 2.5 V. The data within this register is volatile and is set to 0s upon reset. This register has read/write capability. Table 30. AUX_DAC Bit Descriptions Bit 15:12 11:0 Rev. A | Page 27 of 32 Description Not used Data bits ADIS16201 Table 31. GPIO_CTRL Bit Descriptions GENERAL PURPOSE I/O CONTROL As previously noted, the ADIS16201 provides two generalpurpose, bidirectional I/O pins (GPIOs) that are available to the user for control of auxiliary circuits within the target application. All I/O pins are 5 V tolerant, meaning that the GPIOs support an input voltage of 5 V. All GPIO pins have an internal pull-up resistor of approximately 100 k, and their drive capability is 1.6 mA. The direction, as well as the logic level, can be controlled for these GPIO pins through the GPIO_CTRL control register, as defined in Table 31. These same GPIO pins are also controllable through the ALM_CTRL and MSC_CTRL control registers. The priority for these three control registers in controlling the two GPIO pins is MSC_CTRL has precedence over ALM_CTRL, which has precedence over GPIO_CTRL. Bit 15:10 9 8 7:2 1 0 GPIO_CTRL Register Definition Address 0x33, 0x32 1 Default1 0x0000 Format N/A Access R/W Default is valid only until the first register write cycle. Auxiliary Digital I/O Control Register. The data within this register is volatile and is set to 0s upon reset. Rev. A | Page 28 of 32 Description Not used. General purpose I/O line 0, data direction control. 0: Input 1: Output General purpose I/O line 1, data direction control. 0: Input 1: Output Not used. General purpose I/O line 0 polarity. 0: Low 1: High General purpose I/O line 1 polarity. 0: Low 1: High ADIS16201 APPLICATIONS X_ACCL OUT = -2162LSB Y_ACCL OUT = 0LSB SERIAL PERIPHERAL INTERFACE (SPI) 1 X_ACCL OUT = 0LSB Y_ACCL OUT = -2162LSB 1 DOUT BOTTOM VIEW (Not to Scale) The data out pin (DOUT) is an output pin used to transmit data out of the ADIS16201. The data is transmitted in a 16-bit (2-byte) format, MSB first. 1 X_ACCL OUT = 0LSB Y_ACCL OUT = +2162LSB DIN The data-in pin (DIN) is an input pin that is used for the reception of data from the master. The data is received in a 16-bit (2-byte) format with the W/R control bit and address contained in the first data byte and the data contained within the second data byte, MSB first. 1 X_ACCL OUT = +2162LSB Y_ACCL OUT = 0LSB EARTH'S SURFACE SCLK The serial clock pin (SCLK) is used to synchronize the data being transmitted and received through the SCLK period. Therefore, a 16-bit (2-byte) word is transmitted/received after 16 SCLK periods. The SCLK pin is configured as an input. CS In the ADIS16201 a transfer is initiated by the assertion of the chip select pin (CS), which is an active-low signal. The SPI port then transmits and receives data in 16-bit blocks until the transfer is concluded by de-assertion of CS. The control registers within the ADIS16201 are based upon a 16-bit (2-byte) format. Data is loaded in from the DIN pin of the ADIS16201 on the rising edge of SCLK. This requires 16 serial clocks for every data transfer framed by the low period of the CS line. The part operates in full duplex mode with the data clocked out of the DOUT pin, likewise on the rising edge of the SCLK. For each read command received, the corresponding output data is clocked out of the DOUT pin during the following cycle, as defined by the CS line. OUTPUT RESPONSE Figure 39 displays the typical output response for the ADIS16201 for several gravitational measurement orientations. This is a convenient plot for understanding the basic orientation of the inertial sensor measurement axes. NOTES 1. DATA SHOWN IN TWOS COMPLEMENT FORMAT. 05462-039 The ADIS16201 integrates a hardware SPI on-chip. SPI is an industry-standard synchronous serial interface that allows data to be transmitted and received simultaneously, that is, full duplex up to a maximum bit rate of 2.5 Mbps depending upon the sample period selection. The SPI port is configured for slave operation and consists of four pins. Figure 39. Output Response vs. Orientation HARDWARE CONSIDERATIONS The ADIS16201 can be operated from a single 3.3 V (3.0 V to 3.6 V) power supply. The ADIS16201 integrates two decoupling capacitors that are 1 F and 0.1 F in value. For the local operation of the ADIS16201, no additional power supply decoupling capacitance is required. However, if the system power supply presents a substantial amount of noise, additional filtering can be required. If additional capacitors are required, connect the ground terminal of each of these capacitors directly to the underlying ground plane. Finally, note that all analog and digital grounds should be referenced to the same system ground reference point. GROUNDING AND BOARD LAYOUT RECOMENDATIONS Maintaining low impedance signal return paths can be very critical in managing system-level noise effects. For best results, use a single, continuous ground plane that is tied to each ADIS16201 ground pin via short via and trace lengths. In addition to maintaining a low-impedance ground structure, routing the SPI signals away from any sensitive analog circuits, such as the ADC and DACs (if they are in use), can help mitigate system-level noise risks. Rev. A | Page 29 of 32 ADIS16201 BANDGAP REFERENCE The ADIS16201 provides an on-chip band gap reference of 2.5 V, which is utilized by the on-board ADC and DAC. This internal reference also appears on the VREF pin. This reference can be connected to external circuits in the system. An external buffer would be required because of the low drive capability of the VREF output. CRITICAL ZONE TL TO TP tP TP TEMPERATURE RAMP-UP TL tL TSMAX TSMIN tS RAMP-DOWN 05462-042 PREHEAT POWER-ON RESET OPERATION t25C TO PEAK An internal power-on reset (POR) is implemented internally to the ADIS16201. For VDD below 2.35 V, the internal POR holds the ADIS16201 in reset. As VDD rises above 2.35 V, an internal timer times out for typically 130 ms before the part is released from reset. The user must ensure that the power supply has reached a stable 3.0 V minimum level by this time. Likewise, on power-down, the internal POR holds the ADIS16201 in reset until VDD has dropped below 2.35 V. Figure 40 illustrates the operation of the internal POR in detail. TIME Figure 41. Acceptable Solder Reflow Profiles Table 32. Profile Feature Average Ramp Rate (TL to TP) Preheat Minimum Temperature (TSMIN) Maximum Temperature (TSMAX) Time (TSMIN to TSMAX) (ts) 2.35V TYP VDD 05462-040 130ms TYP POR TSMAX to TL Ramp-Up Rate Time Maintained Above Liquidous (TL) Liquidous Temperature (TL) Time (tL) Figure 40. Internal Power-On Reset Operation Peak Temperature (TP) SECOND-LEVEL ASSEMBLY The ADIS16201 can be attached to the second-level assembly board using SN63 (or equivalent) or lead-free solder. Figure 41 and Table 32 provide acceptable solder reflow profiles for each solder type. Note: These profiles may not be the optimum profile for the user's application. In no case should 260C be exceeded. It is recommended that the user develop a reflow profile based upon the specific application. In general, keep in mind that the lowest peak temperature and shortest dwell time above the melt temperature of the solder result in less shock and stress to the product. In addition, evaluating the cooling rate and peak temperature can result in a more reliable assembly. Time Within 5C of Actual Peak Temperature (tp) Ramp-Down Rate Time 25C to Peak Temperature Condition Sn63/Pb37 3C/sec max Pb-Free 3C/sec max 100C 150C 60 sec to 120 sec 150C 200C 60 sec to 150 sec 3C/sec 3C/sec 183C 60 sec to 150 sec 240C + 0C/-5C 10 sec to 30 sec 6C/sec max 6 min max 217C 60 sec to 150 sec 260C + 0C/-5C 20 sec to 40 sec 6C/sec max 8 min max EXAMPLE PAD LAYOUT 1.178 BSC (8 PLCS) 0.670 BSC (12 PLCS) 7.873 BSC (2 PLCS) 0.500 BSC (16 PLCS) Figure 42. Example Pad Layout Rev. A | Page 30 of 32 05462-041 1.127 BSC (16 PLCS) ADIS16201 OUTLINE DIMENSIONS 1.405 BSC 9.327 MAX SQ A1 CORNER INDEX AREA 16 13 12 1 9 4 0.797 BSC 1.00 BSC 5 8 TOP VIEW BOTTOM VIEW 0.227 BSC (4 PLCS) 0.373 BSC (16 PLCS) 5.00 TYP 030906-A 3.90 MAX SIDE VIEW Figure 43. 16-Terminal Land Grid Array [LGA] (CC-16-2) Dimensions shown in millimeters ORDERING GUIDE Model ADIS16201CCCZ 1 ADIS16201/PCB 1 Temperature Range -40C to +125C Package Description 16-Terminal Land Grid Array [LGA] Evaluation Board Z = Pb-free part. Rev. A | Page 31 of 32 Package Option CC-16-2 ADIS16201 NOTES (c)2006 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D05462-0-5/06(A) Rev. A | Page 32 of 32