INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R03
CPC1114N
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 60 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Disipation 170 mW
Total Power Dissipation 2400 mW
Isolation Voltage, Input to Output 1500 Vrms
ESD Rating, Human Body Model 8 kV
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 3.33 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous 1IF=0mA IL- - 400 mArms / mADC
Peak IF=0mA, t<10ms ILPK - - 1000 mA
On-Resistance 2IF=0mA, IL=400mA RON - 1.2 2
Off-State Leakage Current IF=2mA, VL=60VPILEAK --1µA
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.46 2 ms
Turn-Off toff - 2.1 5
Output Capacitance IF=2mA, VL=50V, f=1MHz
COUT
-24-
pF
IF=2mA, VL=1V, f=1MHz - 114 -
Input Characteristics
Input Control Current to Activate (Output Open) 3-I
F- 0.58 2 mA
Input Control Current to Deactivate (Output Closed) IL=120mA IF0.1 0.56 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.5 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Capacitance, Input to Output VIO=0V, f=1MHz CIO -1-pF
1 Load current derates linearly from 400mA @ 25oC to 200mA @85oC.
2 Measurement taken within 1 second of on-time.
3 For applications requiring high temperature operation (greater than 60oC) a minimum LED drive current of 4mA is recommended.
Electrical Characteristics @ 25ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to the
device. Functional operation of the device at conditions beyond
those indicated in the operational sections of this data sheet is
not implied.
Typical values are characteristic of the device at +25°C, and
are the result of engineering evaluations. They are provided for
information purposes only, and are not part of the manufacturing
testing requirements.