SECTION 1: Identification
1.1. Product identifier
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE
Product Identification Numbers
80-6112-1602-1
1.2. Recommended use and restrictions on use
Recommended use
TAPE FOR ELECTRICAL CONTINUITY
1.3. Suppliers details
MANUFACTURER: 3M
DIVISION: 3M Taiwan
Electrical Markets Division
ADDRESS: 3M Center, St. Paul, MN 55144-1000, USA
Telephone: 1-888-3M HELPS (1-888-364-3577)
1.4. Emergency telephone number
1-800-364-3577 or (651) 737-6501 (24 hours)
SECTION 2: Hazard identification
2.1. Hazard classification
Not classified as hazardous according to OSHA Hazard Communication Standard, 29 CFR 1910.1200.
2.2. Label elements
Signal word
Not applicable.
Symbols
Not applicable.
Pictograms
Not applicable.
2.3. Hazards not otherwise classified
None.
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE 09/02/14
__________________________________________________________________________________________
Page 2 of 7
SECTION 3: Composition/information on ingredients
Ingredient C.A.S. No. % by Wt
Silicone polymer on paper as release liner Unknown 35 - 45
Metallized glass spheres Mixture <= 1
Copper Alloy Foil None 80 - 90
Conductive Acrylate Pressure Sensitive Adhesive Trade Secret* 10 - 20
*The specific chemical identity and/or exact percentage (concentration) of this composition has been withheld as a trade
secret.
SECTION 4: First aid measures
4.1. Description of first aid measures
Inhalation:
No need for first aid is anticipated.
Skin Contact:
No need for first aid is anticipated.
Eye Contact:
No need for first aid is anticipated.
If Swallowed:
No need for first aid is anticipated.
4.2. Most important symptoms and effects, both acute and delayed
See Section 11.1. Information on toxicological effects.
4.3. Indication of any immediate medical attention and special treatment required
Not applicable
SECTION 5: Fire-fighting measures
5.1. Suitable extinguishing media
In case of fire: Use a fire fighting agent suitable for ordinary combustible material such as water or foam to extinguish.
5.2. Special hazards arising from the substance or mixture
None inherent in this product.
5.3. Special protective actions for fire-fighters
No special protective actions for fire-fighters are anticipated.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Ventilate the area with fresh air. Observe precautions from other sections.
6.2. Environmental precautions
Avoid release to the environment.
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE 09/02/14
__________________________________________________________________________________________
Page 3 of 7
6.3. Methods and material for containment and cleaning up
Collect as much of the spilled material as possible. Sweep up. Place in a closed container approved for transportation by
appropriate authorities. Clean up residue. Seal the container. Dispose of collected material as soon as possible.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Avoid skin contact with hot material. Avoid breathing of dust created by cutting, sanding, grinding or machining. For
industrial or professional use only. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.) Keep away from
reactive metals (eg. Aluminum, zinc etc.) to avoid the formation of hydrogen gas that could create an explosion hazard.
7.2. Conditions for safe storage including any incompatibilities
Store away from acids. Store away from strong bases. Store away from oxidizing agents. Store away from amines.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Occupational exposure limits
No occupational exposure limit values exist for any of the components listed in Section 3 of this SDS.
8.2. Exposure controls
8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.
8.2.2. Personal protective equipment (PPE)
Eye/face protection
Select and use eye/face protection to prevent contact based on the results of an exposure assessment. The following eye/face
protection(s) are recommended:
Full Face Shield
Indirect Vented Goggles
Skin/hand protection
No chemical protective gloves are required.
Respiratory protection
Respiratory protection is not required.
Thermal hazards
Wear heat insulating gloves when handling hot material to prevent thermal burns.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
General Physical Form: Solid
Specific Physical Form: Roll of Tape
Odor, Color, Grade: Copper-orange essentially odorless with paper release liner.
Odor threshold No Data Available
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE 09/02/14
__________________________________________________________________________________________
Page 4 of 7
pH Not Applicable
Melting point No Data Available
Boiling Point Not Applicable
Flash Point No Data Available
Evaporation rate Not Applicable
Flammability (solid, gas) Not Classified
Flammable Limits(LEL) Not Applicable
Flammable Limits(UEL) Not Applicable
Vapor Pressure Not Applicable
Vapor Density Not Applicable
Specific Gravity Approximately 5.3 Units not avail. or not appl. [Ref Std:
WATER=1]
Solubility in Water Nil
Solubility-non-water No Data Available
Partition coefficient: n-octanol/ water No Data Available
Autoignition temperature No Data Available
Decomposition temperature No Data Available
Viscosity Not Applicable
Volatile Organic Compounds Not Applicable
Percent volatile Not Applicable
VOC Less H2O & Exempt Solvents Not Applicable
SECTION 10: Stability and reactivity
10.1. Reactivity
This material may be reactive with certain agents under certain conditions -see the remaining headings in this section.
10.2. Chemical stability
Stable.
10.3. Possibility of hazardous reactions
Hazardous polymerization will not occur.
10.4. Conditions to avoid
Not determined
10.5. Incompatible materials
Strong acids
Strong bases
Strong oxidizing agents
Amines
Finely divided active metals
10.6. Hazardous decomposition products
Substance Condition
Carbon monoxide Not Specified
Carbon dioxide Not Specified
Irritant Vapors or Gases Not Specified
Organic Acids Not Specified
SECTION 11: Toxicological information
The information below may not be consistent with the material classification in Section 2 if specific ingredient
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE 09/02/14
__________________________________________________________________________________________
Page 5 of 7
classifications are mandated by a competent authority. In addition, toxicological data on ingredients may not be
reflected in the material classification and/or the signs and symptoms of exposure, because an ingredient may be
present below the threshold for labeling, an ingredient may not be available for exposure, or the data may not be
relevant to the material as a whole.
11.1. Information on Toxicological effects
Signs and Symptoms of Exposure
Based on test data and/or information on the components, this material may produce the following health effects:
Inhalation:
No health effects are expected.
Skin Contact:
Contact with the skin during product use is not expected to result in significant irritation.
Eye Contact:
Contact with the eyes during product use is not expected to result in significant irritation.
Ingestion:
No health effects are expected.
Toxicological Data
If a component is disclosed in section 3 but does not appear in a table below, either no data are available for that endpoint or
the data are not sufficient for classification.
Acute Toxicity
Name Route Species Value
Overall product Ingestion No data available; calculated ATE > 5,000 mg/kg
ATE = acute toxicity estimate
Skin Corrosion/Irritation
Name Species Value
Serious Eye Damage/Irritation
Name Species Value
Skin Sensitization
Name Species Value
Respiratory Sensitization
Name Species Value
Germ Cell Mutagenicity
Name Route Value
Carcinogenicity
Name Route Species Value
Reproductive Toxicity
Reproductive and/or Developmental Effects
Name Route Value Species Test Result Exposure
Duration
Target Organ(s)
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE 09/02/14
__________________________________________________________________________________________
Page 6 of 7
Specific Target Organ Toxicity -single exposure
Name Route Target Organ(s) Value Species Test Result Exposure
Duration
Specific Target Organ Toxicity -repeated exposure
Name Route Target Organ(s) Value Species Test Result Exposure
Duration
Aspiration Hazard
Name Value
Please contact the address or phone number listed on the first page of the SDS for additional toxicological information
on this material and/or its components.
SECTION 12: Ecological information
Ecotoxicological information
Please contact the address or phone number listed on the first page of the SDS for additional ecotoxicological information on this material
and/or its components.
Chemical fate information
Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material
and/or its components.
SECTION 13: Disposal considerations
13.1. Disposal methods
Dispose of contents/ container in accordance with the local/regional/national/international regulations.
Prior to disposal, consult all applicable authorities and regulations to insure proper classification. Dispose of waste product in
a permitted industrial waste facility. As a disposal alternative, incinerate in a permitted waste incineration facility. Proper
destruction may require the use of additional fuel during incineration processes. If no other disposal options are available,
waste product may be placed in a landfill properly designed for industrial waste.
EPA Hazardous Waste Number (RCRA): Not regulated
SECTION 14: Transport Information
For Transport Information, please visit http://3M.com/Transportinfo or call 1-800-364-3577 or 651-737-6501.
SECTION 15: Regulatory information
15.1. US Federal Regulations
Contact 3M for more information.
311/312 Hazard Categories:
Fire Hazard -No Pressure Hazard -No Reactivity Hazard -No Immediate Hazard -No Delayed Hazard -No
15.2. State Regulations
Contact 3M for more information.
3M 1126 AND DC1126 COPPER FOIL CONDUCTIVE ADHESIVE TAPE 09/02/14
__________________________________________________________________________________________
Page 7 of 7
15.3. Chemical Inventories
Contact 3M for more information.
15.4. International Regulations
Contact 3M for more information.
This SDS has been prepared to meet the U.S. OSHA Hazard Communication Standard, 29 CFR 1910.1200.
SECTION 16: Other information
NFPA Hazard Classification
Health: 0 Flammability: 1 Instability: 0 Special Hazards: None
National Fire Protection Association (NFPA) hazard ratings are designed for use by emergency response personnel to address
the hazards that are presented by short-term, acute exposure to a material under conditions of fire, spill, or similar
emergencies. Hazard ratings are primarily based on the inherent physical and toxic properties of the material but also include
the toxic properties of combustion or decomposition products that are known to be generated in significant quantities.
HMIS Hazard Classification
Health: 0 Flammability: 1 Physical Hazard: 0 Personal Protection: X -See PPE section.
Hazardous Material Identification System (HMIS® III) hazard ratings are designed to inform employees of chemical hazards
in the workplace. These ratings are based on the inherent properties of the material under expected conditions of normal use
and are not intended for use in emergency situations. HMIS® III ratings are to be used with a fully implemented HMIS® III
program. HMIS® is a registered mark of the American Coatings Association (ACA).
Document Group: 16-2386-7 Version Number: 3.00
Issue Date: 09/02/14 Supercedes Date: 01/23/13
DISCLAIMER: The information in this Safety Data Sheet (SDS) is believed to be correct as of the date issued. 3M MAKES
NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR COURSE OF PERFORMANCE OR
USAGE OF TRADE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable
for user's method of use or application. Given the variety of factors that can affect the use and application of a 3M product,
some of which are uniquely within the user's knowledge and control, it is essential that the user evaluate the 3M product to
determine whether it is fit for a particular purpose and suitable for user's method of use or application.
3M provides information in electronic form as a service to its customers. Due to the remote possibility that electronic transfer
may have resulted in errors, omissions or alterations in this information, 3M makes no representations as to its completeness
or accuracy. In addition, information obtained from a database may not be as current as the information in the SDS available
directly from 3M
3M USA SDSs are available at www.3M.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
3M:
1126-23x36 1126-2X36