DO NOT
SCALE FROM
THIS PRINT
BCS-1XX-XXX-X-XX-XXX
No OF POSITIONS
-01 THRU -50
BODY SPECIFICATION
-S: SINGLE ROW (SEE TABLE 1)
-D: DOUBLE ROW (SEE TABLE 1)
PLATING SPECIFICATIONS
(SEE TABLE 1)
POLARIZING OPTION
INSERT PK-06-N INTO SPECIFIED
POS AND BREAK OFF TAB
(NOT AVAILABLE FOR -BE OPTION)
ENTRY SPECIFICATION
-DE: DUAL ENTRY (SEE TABLE 1)
-TE: TOP ENTRY (SEE TABLE 1)
-HE: HORIZONTAL ENTRY (SEE TABLE 1)
-PE: PASS-THROUGH ENTRY (SEE TABLE 1)
-DE-BE: (SEE TABLE 1)
-PE-BE: (SEE TABLE 1)
-T: MATTE TIN CONTACT AND TAIL
-L: 10µ" LIGHT SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-F: 3µ" FLASH SELECTIVE GOLD CONTACT AREA,
MATTE TIN ON TAIL
-S: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-H: 30µ" HEAVY GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
-SM: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-TM: MATTE TIN CONTACT AND TAIL
-LM: 10µ" LIGHT SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-FM: 3µ" FLASH SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-LTL:
10µ’’ LIGHT SELECTIVE GOLD IN CONTACT AREA,
TIN LEAD (90/10 +/-5%) ON TAIL
.119 3.02
(SEE NOTE 9)
2
MAX SWAY
IN EITHER DIRECTION
C
-DE/-DE-BE
FIG 1
(CUT TO POSITION: ±.008[.20] - SEE NOTE 4)
NO. OF POSITIONS x .100[2.54]
(MOLD TO POSITION: )
.100
REF
2.54
(NO. OF POS x .100[2.54]) - (.100[2.54])
.050
REF
1.27
"B"
"B"
1st POSITION
-01
-02 -50
-49
+.000[0.00]
-.005[0.13]
C
(-DE TAIL ORIENTATION)
(-HE TAIL ORIENTATION)
.200
REF
5.08
.100
REF
2.54
"A"
"A"
-49
-50 -02
-01
.290 7.37
REF
.16 4.1
2
MAX TOE
SECTION "A"-"A"
CONTACT #49
BCS-1XX-X-D-DE
CONTACT #50
C
.06 1.6
2
MAX TOE
SECTION "B"-"B"
C
CONTACT #2
BCS-1XX-X-S-DE
CONTACT #1
C
(-TE TAIL ORIENTATION)
(-PE TAIL ORIENTATION)
SHEET OF
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS ANGLES
.XX:
.01 [.3] 2
.XXX:
.005 [.13]
.XXXX:
.0020 [.051]
MATERIAL:
BOX CONNECTOR SOCKET STRIP
BY:
BCS-1XX-XXX-X-XX-XXX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
KOLB
09/12/1991
3
1
SHEET SCALE: 2:1
INSULATOR: GLASS FILLED LCP UL 94 VO, COLOR: BLACK
CONTACT: PHOS. BRONZE
F:\DWG\MISC\MKTG\BCS-1XX-XXX-X-XX-XXX-MKT.SLDDRW
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
NOTES:
1. REPRESENTS CRITICAL DIM. FOR STATISTICAL PROCESS CONTROL.
2. PUSHOUT FORCE TO BE: 1 lb. MIN.
3. [ ] DIMENSIONS ARE IN MILLIMETERS.
4. MIN WALL THICKNESS ON CUT PARTS: .009 [.23].
5. CUT PARTS TO BE SYMMETRICAL ABOUT
C
L
.
6. 1st POSITION WILL ALWAYS POINT UP ON TOP VIEW AS SHOWN.
7. 1 THROUGH 4 POSITIONS ARE TO BE LAYER PACKAGED, 5 THROUGH
50 POSITIONS ARE TO BE TUBED FOR THIS PART NUMBER.
8. DAMAGE TO THE CUT SURFACE CAN NOT EFFECT LEAD-IN OF THE CORES.
9. MAX VARIATION WITHIN A ROW: .006 [.15]
MAX VARIATION FROM ROW TO ROW: .012 [.30]
REVISION BT
.210 5.33
REF
(NO. OF POS x .100[2.54])±.008[0.20]
.225 5.72
REF
(NO. OF POS x .100[2.54]) - .100[2.54]
.050
REF
1.27
.100
REF
2.54
2
MAX SWAY
IN EITHER DIRECTION
"D"
"D"
01
50
BCS-1XX-X-D-HE
.320 8.13
REF
2
MAX SWAY
(EITHER DIRECTION)
2
MAX SWAY
(EITHER DIRECTION)
2
MAX SWAY
(EITHER DIRECTION)
02
49
C C
.110
REF
2.79
.125
REF
3.18
2
MAX SWAY
IN EITHER DIRECTION
"C"
"C"
-01 -50
.320 8.13
REF
.143 3.63
.147 3.73
IN-PROCESS
-S-HE
C
C
.150 3.81
.250
-
.003
+
.005 6.35
-
0.076
+
0.127
CONTACT #2
CONTACT #1
C
C
IN-PROCESS
-D-HE
.290 7.37
REF
.122 3.10
CONTACT #1
C
C
.122 3.10
.10 2.6
CONTACT #1
BCS-1XX-X-S-TE
BCS-1XX-XXX-D-TE
FIG 4
-PE/-PE-BE
(SEE SHEET 3 FOR IN-PROCESS)
C
.293
REF
7.44
.30 7.6
.128
±.010
3.25
±0.254
CONTACT #1
C
C
.128
±.010
3.25
±0.254
.20 5.1
CONTACT #1
C
C
.015
REF
0.38
.31 7.9
.125
-
.015
+
.010 3.18
-
0.381
+
0.254
2
MAX TOE
(EITHER DIRECTION)
SECTION "C"-"C"
CONTACT # 2
C
.310 7.88
.310
-
.010
+
.015 7.87
-
0.254
+
0.381
.125
-
.015
+
.010 3.16
-
0.381
+
0.254
.015
REF
0.38
.0700
REF
1.779
2
MAX TOE
(EITHER DIRECTION)
SECTION "D"-"D"
CONTACT #49
CONTACT #50
C
FIG 2
-HE
FIG 3
-TE
BCS-1XX-XXX-D-PE
BCS-1XX-X-S-PE
BCS-1XX-X-S-HE
SHEET OF
BOX CONNECTOR SOCKET STRIP
BY:
BCS-1XX-XXX-X-XX-XXX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
KOLB
09/12/1991
3
2
SHEET SCALE: 2:1
REVISION BT
F:\DWG\MISC\MKTG\BCS-1XX-XXX-X-XX-XXX-MKT.SLDDRW
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.176 4.47
IN-PROCESS 1
C
.176 4.47
IN-PROCESS 1
C
-01
(SEE NOTE 6)
-02 -50
-49
-S-PE-BE: (SAME AS -S-PE EXCEPT AS SHOWN)
-D-PE-BE: (SAME AS -D-PE)
PT-1-24-01-15
BCS-D-PE
BCS-D-PE
BCS-D-PE-BE
BCS-D-PE-DE-BE
BCS-S-DE
BCS-S-DE-BE
PT-3-24-01-01
PT-1-24-04-38
BCS-S-HE
PT-1-24-03-29
BCS-D-HE
PT-1-24-01-22
BCS-D-TE
PT-1-24-01-24
BCS-S-TE
.544
REF
13.83
IN-PROCESS 2
.445
REF
11.31
IN-PROCESS 2
-01
-02 -50
-49
-01
-02
-50
-49
-S-BE: (SAME AS FIG 1 EXCEPT AS SHOWN
-D-BE: (SAME AS FIG 1)
-49
-50 -01
-02
PT-1-24-20-09
BCS-S-PE
BCS-S-PE-BE
IN-PROCESS
BCS-1XX-X-D-PE
(SAME FOR -BE)
IN-PROCESS
BCS-1XX-X-S-PE
(SAME FOR -BE)
SHEET OF
BOX CONNECTOR SOCKET STRIP
BY:
BCS-1XX-XXX-X-XX-XXX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
KOLB
09/12/1991
3
3
SHEET SCALE: 2:1
REVISION BT
F:\DWG\MISC\MKTG\BCS-1XX-XXX-X-XX-XXX-MKT.SLDDRW
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322