PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 247
11
The PolySwitch families of telecommunications and
networking devices help meet the growing demand
for resettable overcurrent protection. These product
families help provide protection against damage caused
by power cross and power induction surges as defined
in ITU, Telcordia GR1089 and UL60950. Available in
chip, surface-mount and radial-leaded configurations,
TE’s PolySwitch devices help improve the reliability of
customer premise and network equipment worldwide.
Many product choices give engineers help increase
design flexibility
Compatible with high-volume electronics assembly
Assist in meeting regulatory equipment requirements
Help improve line balance
Applicable for legacy POTS and modern digital
communications equipment
RoHS compliant
Resettable overcurrent protection
Surface-mount, radial-leaded and chip form factors
Fast time-to-trip
Agency recognition: UL, CSA, TÜV
Resistance-sorted and matched devices available
Low parasitic capacitance/flat impedance
with frequency
• Modems
Phone sets
Fax machines
Phone wall outlets
Alarm systems
PolySwitch Resettable Devices
Telecommunications and Networking Devices
Benefits Features
Applications
PBX systems
MDF modules
Analog and digital line cards
T1/E1 equipment
xDSL modems and splitters
Powered ethernet systems
VoIP (Voice over Internet Protocol) equipment
LAN, WAN equipment
Customer premise equipment
Access network hardware
2013_CP_S11-Poly-8-TeleNetwork.indd 247 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
248
11
Application Guide for PolySwitch Telecommunications and Networking Devices*
To use this guide, follow the steps below:
1. Select your equipment type from the guide below.
2. Select the type of protection depending on the agency and regional specifications in the second column.
3. Select the form factor for your application.
4. Use the Agency Specification/ PolySwitch Device Selection Guide on the next page to select a specific part number for each application
based on the agency requirements.
5. Parts with fast time-to-trip or low resistance are available. Please consult a TE Circuit Protection representative.
Application
Region/
Specification
Form Factor
Radial-leaded Surface-mount Chip
Overcurrent Protection
Customer Premise equipment
IT equipment
Analog Modems, V.90 Modems,
ISDN Modems, xDSL Modems,
ADSL Splitters, Phone Sets, Fax Machines,
Answering Machines, Caller ID, Internet
Appliances, PBX Systems, POS Terminals,
Wall Plugs
North America TRF600-150 TS600-170F
TIA-968-A, TR600-150F-EX TS600-200F
UL 60950, TRF600-160 TSM600-250F
GR1089 Port Type 3TRF600-250 TSM600-400F
TRF-600-400
Europe/Asia/ TRF250-120 TS250-130F
South America TRF250-120T TSV250-130F
ITU K.21 TRF250-145 TSV250-184F
TRF250-183
TRF250-184
Access network equipment (†)
Remote Terminals, Line Repeaters,
Multiplexers, Cross-Connects,
WAN Equipment
North America TRF600-160 TS600-170F
GR1089 Port Type 5TRF600-250 TS600-200F
TRF600-400 TS600-400F
TSM600-250F
TSM600-400F
FT600-1250**
Europe/Asia/ TRF250-120 TS250-130F
South America TRF250-120T TSV250-130F
ITU K.45 TRF250-145 TSV250-184F
TRF250-183
TRF250-184
Central office switching equipment (†)
Analog/POTS Linecards, ISDN Linecards,
xDSL Modems, ADSL/VDSL Splitters,
T1/E1 Linecards, Multiplexers,
CSU/DSU, Servers
North America TRF600-160 TS600-170F
GR1089 Port Type 1TRF600-250 TS600-200F
TRF600-400 TS600-400F
TSM600-250F
TSM600-400F
FT600-1250**
Europe/Asia/ TRF250-120 TS250-130F TCF250-180
South America TRF250-120T TSV250-130F
ITU K.20 TRF250-145 TSV250-184F
TRF250-183
TRF250-184
Primary protection modules (†)
MDF modules, Network Interface
Devices (NID)
North America TRF250-183 TSV250-184F
Telcordia GR-974 TRF250-184
Europe/Asia/ TRF250-055UT TSL250-080F TCF250-100T
South America TRF250-080U TS250-130F TCF250-120T
ITU K.20 TRF250-110U TSV250-130F TCF250-145T
TRF250-120 TSV250-184F TCF250-180
TRF250-120T
TRF250-145
TRF250-183
TRF250-184
Short-haul/intrabuilding communications
equipment (†)
LAN Equipment, VoIP Cards, Cable
Telephony NIUs, Wireless Local Loop
Handsets
North America TRF250-080U TSL250-080F
GR1089 Port Type 2TRF250-120 TS250-130F
GR1089 Port Type 4TRF250-120T TSV250-130F
TRF250-145 TSV250-184F
TRF250-183
TRF250-184
Europe/Asia/ TRF250-120 TS250-130F
South America TRF250-120T TSV250-130F
ITU K.21 TRF250-145 TSV250-184F
TRF250-183
TSV250-184
* Applies to all products which share the same prefix. † Tested with 230V gas discharge tube primary protector.
2013_CP_S11-Poly-8-TeleNetwork.indd 248 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 249
11
Protection Application Guide for PolySwitch Telecommunications and Networking Devices*
Cont’d
Agency Specification/Selection Guide for Telecommunications and Networking Devices
Use the guide below to select the PolySwitch devices that are typically used in your application. The following pages contain the
specifications for the part numbers recommended below. PolySwitch devices assist telecommunication equipment in meeting the applicable
protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics.
Users should independently evaluate the suitability of and test each product for their application.
Family Product* Lightning Power Cross/Contact/Induction
TCF250 TCF250-100T ITU K.20 – 1.0kV 10/700µs PRC YD/T694
GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 0.2A2s
ITU K.20/21/45 – 1A2s
GR-1089 Port Type 4 – 120VAC, 25Asc
TCF250-120T ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω
TCF250-145T ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A2s
TCF250-180 GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A2s
ITU K.20/21/45 – 10A2s
GR-1089 Port Type 4 – 120VAC, 25Asc
* Applies to all products which share the same prefix.
Tested with 230V gas discharge tube primary protector.
Application
Region/
Specification
Form Factor
Radial-leaded Surface-mount Chip
Overcurrent Protection
* This list is not exhaustive. TE Circuit Protection welcomes our customers’ input for additional application ideas for PolySwitch resettable devices.
For improved line balance in these applications, resistance-matched parts are recommended.
May require additional impedance or coordination with primary protector.
** FT600-1250 are surface-mount telecom fuse devices. FT600-0500 and FT600-2000 reference also available. See telecom fuses section.
†† For details on decaSMDC050F/60-2, see surface-mount devices section.
LAN Intrabuilding Power Cross Protection
LAN Equipment, VoIP Cards, IP Phones
North America
GR1089 Port Type 4
TSL250-080U TSL250-080F
TRF250-120 TS250-130F
TRF250-120T TSV250-130F
TRF250-145 TSV250-184F
TRF250-183
TRF250-184
IEEE 802.3AF/AT Power over
Ethernet protection
Powered Ethernet Switches and Terminals,
IP phones, Wireless LAN Base Stations,
Microcellular Base Stations, VoIP Cards
decaSMDC050F/60-2††
2013_CP_S11-Poly-8-TeleNetwork.indd 249 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
250
11
Agency Specification/Selection Guide for PolySwitch Telecommunications and Networking Devices
Cont’d
Family Product* Lightning Power Cross/Contact/Induction
* Applies to all products that share the same prefix.
Tested with 230V gas discharge tube primary protector.
Tested with 350V gas discharge tube primary protector.
** See SCD for additional application fault ratings.
†† May require additional series resistor to help telecommunication equipment pass Surge 3 (1kV, 10/1000µs).
‡‡ See telecom fuses section.
TRF250 TRF250-055UT ITU K.20 – 1.0kV 10/700µs ITU K.20 – 230VAC, 10Ω
TRF250-080U ITU K.20 – 1.0kV 10/700µs ITU K.20 – 230VAC, 10Ω
GR-1089 Port Types 2 and 4 – 1st Level ITU K.20 – 0.2A2s
ITU K.20 – 1A2s†
GR-1089 Port Type 4 – 120VAC, 25Asc
TRF250-110U ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω
TRF250-120 ITU K.20/21/45 – 4.0kV 10/700µs† ITU K.20/21/45 – 0.2A2s
TRF250-120T GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A2s†
TRF250-120U ITU K.20/21/45 – 10A2s†
TRF250-120UT GR-1089 Port Type 4 – 120VAC, 25Asc
TRF250-145
TRF250-145U
TRF250-183
TRF250-184 ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω**
ITU K.20/21/45 – 4.0kV 10/700µs‡ ITU K.20/21/45 – 0.2A2s
GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A2s‡
ITU K.20/21/45 – 10A2s‡
GR-1089 Port Type 4 – 120VAC, 25Asc
TS250/TSV250 TSV250-130F ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω
TS250-130F ITU K.20/21/45 – 4.0kV 10/700µs† ITU K.20/21/45 – 0.2A2s
GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A2s†
ITU K.20/21/45 – 10A2s†
GR-1089 Port Type 4 – 120VAC, 25Asc
TS250-130F-RB ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω
ITU K.20/21/45 – 4.0kV 10/700µs‡ ITU K.20/21/45 – 0.2A2s
GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A2s‡
ITU K.20/21/45 – 10A2s‡
GR-1089 Port Type 4 – 120VAC, 25Asc
TSV250-184F ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω**
ITU K.20/21/45 – 4.0kV 10/700µs‡ ITU K.20/21/45 – 0.2A2s
GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A2s‡
ITU K.20/21/45 – 10A2s‡
GR-1089 Port Type 4 – 120VAC, 25Asc
TSL250 TSL250-080F GR-1089 Port Types 2 and 4 – 1st Level GR-1089 Port Type 4 – 120VAC, 25Asc
ITU K.20 – 1.0kV 10/700µs ITU K.20/21/45 – 230VAC, 10Ω
ITU K.20/21/45 – 0.2A2s
ITU K.20/21/45 – 1A2s†
TRF600 TRF600-150 TIA-968-A Types A & B UL60950 – 600VAC, 40Asc
TR600-150F-EX GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level†† UL60950 – 600VAC, 40Asc
TR600-150F-EX-RA-B-0.5 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level†† UL60950 – 600VAC, 40Asc
TRF600-160 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc
TRF600-250 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc
TRF600-400 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600VAC, 60Asc
TS600 TS600-170F TIA-968-A Types A & B UL60950 – 600VAC, 40Asc
TS600-200F-RA GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc
TS600-400F
TSM600 TSM600-250F TIA-968-A Types A & B UL60950 – 600VAC, 40Asc
TSM600-250F-RA GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level†† Telcordia GR-1089 – 600VAC, 60Asc
TSM600-400F TIA-968-A Types A & B UL60950 – 600VAC, 40Asc
GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600VAC, 60Asc
FT600‡‡ FT600-0500 TIA-968-A - Types A & B UL60950 - 600VAC, 40Asc
FT600-1250
FT600-2000 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600VAC, 60Asc
2013_CP_S11-Poly-8-TeleNetwork.indd 250 9/3/13 3:02 PM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 251
11
TS600
TCF250 TRF250 TS250 TSV250 TSL250 TSM600 TRF600
VMAX Interrupt (VAC)* 250 250 250 250 250 600 600
ITU ITU ITU ITU UL60950 UL60950
GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089
Specification Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 1, 3 and 5 Ports 1, 3 and 5
Hold Current (A)
0.055 20.0Ω
0.080 17.0Ω 8.0Ω
0.100 11.0Ω
0.110 7.0Ω
0.120 10.5Ω 8.0Ω
0.130 9.0Ω 5.5Ω
0.145 7.0Ω 4.5Ω
0.150 8.0Ω
0.160 6.0Ω
0.170 11.0Ω
0.183 1.3Ω
0.184 1.9Ω 1.6Ω
0.200 8.5Ω
0.250 3.5Ω 3.0Ω
0.400 1.2Ω 1.2Ω
Voltage Ratings for Telecommunications and Networking Devices
For circuit protection telecommunications devices there are two applicable voltage ratings. These are VMAX Operating and
VMAX Interrupt. To help understand the nature of these two different voltage ratings, the following definitions are provided:
VMAX Operating : For telecommunications devices, this is the voltage used to obtain component recognition under UL1434. Most circuit
protection devices are certified at 60V but can withstand higher VMAX Interrupt conditions.
See Table T3 for its VMAX Operating.
*VMAX Interrupt : Under specified conditions, this is the highest voltage that can be applied to the device at the maximum current. Devices
may trip safely under higher power level cross conditions, as listed above, to assist equipment in meeting the appropriate
industry conditions.
Table T1 Product Series: Size, Current Rating, Voltage Rating, Typical Resistance for PolySwitch
Telecommunications and Networking Devices
2013_CP_S11-Poly-8-TeleNetwork.indd 251 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
252
11
% of Rated Hold and Trip Current
Device’s Ambient Temperature (˚C)
200
150
100
50
0-40 -20 0 20 40 60 80
A
A
B
B
Figure T1
A = TCF250-180
B = All other TCF, TRF,
TSM Series Devices
Maximum Ambient Temperature
Part Number -40°C -20°C 0°C 20°C 40°C 50°C 60°C 70°C 85°C
Chip* — 250VAC
TCF250
TCF250-100T 0.155 0.138 0.119 0.100 0.083 0.073 0.064 0.055 0.042
TCF250-120T 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050
TCF250-145T 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060
TCF250-180 0.269 0.240 0.211 0.180 0.153 0.138 0.123 0.109 0.087
Radial-leaded* — 250VAC
TRF250
TRF250-055UT 0.085 0.076 0.065 0.055 0.045 0.041 0.035 0.030 0.023
TRF250-080U 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033
TRF250-110U 0.171 0.151 0.131 0.110 0.091 0.081 0.071 0.061 0.046
TRF250-120 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050
TRF250-145 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060
TRF250-183 0.284 0.251 0.217 0.183 0.149 0.133 0.117 0.101 0.075
TRF250-184 0.286 0.252 0.218 0.184 0.150 0.134 0.118 0.102 0.075
Surface-mount* — 250VAC
TS250/TSL250/TSV250
TSL250-080F 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033
TS250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045
TSV250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045
TSV250-184F 0.286 0.252 0.218 0.184 0.150 0.134 0.118 0.102 0.075
Radial-leaded — 600VAC
TRF600
TRF600-150 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057
TR600-150F-EX 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057
TR600-150F-EX-RA 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057
TRF600-160 0.255 0.223 0.192 0.160 0.129 0.114 0.099 0.084 0.061
TRF600-250 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083
TRF600-400 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130
Surface-mount — 600VAC
TS600/TSM600
TS600-170F 0.264 0.230 0.200 0.170 0.140 0.125 0.109 0.094 0.070
TS600-200F-RA-B-0.5 0.310 0.275 0.238 0.200 0.165 0.147 0.128 0.110 0.083
TS600-400F 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130
TSM600-250F 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083
TSM600-250F-RA 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083
TSM600-400F 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130
* 250VAC interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements.
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Product is not currently available in a resistance matched or sorted option.
Table T2 Thermal Derating for PolySwitch Telecommunications and Networking Devices
[Hold Current (A) at Ambient Temperature (°C)]
Figure T1 Thermal Derating [Hold Current (A) at Ambient Temperature (°C)]
2013_CP_S11-Poly-8-TeleNetwork.indd 252 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 253
11
Chip* — 250VAC
TCF250
TCF250-100T 0.100 0.150 60 250 3.0 0.6 1.0 0.2 14.0 18.0 24.0
TCF250-120T 0.120 0.240 60 250 3.0 1.0 1.0 0.6 6.3 12.0 18.0
TCF250-145T 0.145 0.290 60 250 3.0 1.0 1.0 1.5 5.0 9.0 14.0
TCF250-180 0.180 0.650 60 250 3.0 0.9 1.0 15.5 1.0 2.2 4.0
Radial-leaded* — 250VAC
TRF250
TRF250-055UT 0.055 0.170 60 250 3.0 0.6 0.28 3.0 15.0 25.0 35.0
TRF250-080T 0.080 0.160 60 250 3.0 0.6 0.35 2.5 15.0 22.0 33.0
TRF250-080U 0.080 0.160 60 250 3.0 0.6 0.35 2.5 14.0 20.0 33.0
TRF250-110U 0.110 0.220 60 250 3.0 1.0 1.00 0.8 5.0 9.0 16.0
TRF250-120 0.120 0.240 60 250 3.0 1.0 1.00 1.5 4.0 8.0 16.0
TRF250-120T 0.120 0.240 60 250 3.0 1.0 0.35 0.7 7.0 12.0 16.0
TRF250-120T-RA 0.120 0.240 60 250 3.0 1.0 1.00 1.2 7.0 9.0 16.0
TRF250-120T-RC 0.130 0.260 60 250 3.0 1.0 1.00 1.5 5.4 7.5 14.0
TRF250-120T-RF 0.120 0.240 60 250 3.0 1.0 1.00 0.9 6.0 10.5 16.0
TRF250-120T-R1 0.120 0.240 60 250 3.0 1.0 1.00 1.0 6.0 9.0 16.0
TRF250-120T-R2 0.120 0.240 60 250 3.0 1.0 1.00 0.8 8.0 10.5 16.0
TRF250-120U 0.120 0.240 60 250 3.0 1.0 1.00 1.0 6.0 10.0 16.0
TRF250-120UT 0.120 0.240 60 250 3.0 1.0 1.00 0.7 7.0 12.0 16.0
TRF250-145 0.145 0.290 60 250 3.0 1.0 1.00 2.5 3.0 6.0 14.0
TRF250-145-RA 0.145 0.290 60 250 3.0 1.0 1.00 2.5 3.0 5.5 12.0
TRF250-145-RB 0.145 0.290 60 250 3.0 1.0 1.00 2.0 4.5 6.0 14.0
TRF250-145T 0.145 0.290 60 250 3.0 1.0 1.00 1.5 5.4 7.5 14.0
TRF250-145U 0.145 0.290 60 250 3.0 1.0 1.00 2.0 3.5 6.5 14.0
TRF250-183 0.183 0.685 100 250 10.0 0.9 3.00 0.6 0.8 2.2 3.4
TRF250-184 0.184 1.000 100 250 10.0 0.9 3.00 0.5 1.2 2.4 3.1
Surface-mount* — 250VAC
TS250/TSL250/TSV250
TSL250-080F 0.080 0.240 80 250 3.0 1.2 1.0 0.8 5.0 11.0 20.0**
TS250-130F 0.130 0.260 60 250 3.0 1.1 1.0 0.9 6.5 12.0 20.0**
60 600 1.0
TS250-130F-RA 0.130 0.260 60 250 3.0 1.1 1.0 1.4 6.5 9.0 15.0**
60 600 1.0
TS250-130F-RB 0.130 0.260 60 250 3.0 1.1 1.0 0.7 9.0 12.0 20.0**
60 600 1.0
TS250-130F-RC 0.130 0.260 60 250 3.0 1.1 1.0 1.1 7.0 10.0 17.0**
60 600 1.0
TSV250-130F 0.130 0.260 60 250 3.0 1.5 1.0 2.0 4.0 7.0 12.0**
TSV250-184F 0.184 0.690 100 250 10.0 0.9 3.0 0.5 1.2 3.0 4.0**
Radial-leaded — 600VAC
TRF600
TRF600-150 0.150 0.300 250 600 3.0 1.4 1.0 1.4 6.0 10.0 17.0
TRF600-150-RB 0.130 0.260 250 600 3.0 1.0 1.0 1.0 9.0 12.0 22.0
TR600-150F-EX 0.150 0.300 250 600 3.0 1.4 1.0 5.0 6.0 12.0 22.0
TR600-150F-EX-RA-B-0.5 0.150 0.300 250 600 3.0 1.4 1.0 5.0 7.0 10.0 20.0
TRF600-160 0.160 0.320 250 600 3.0 1.7 1.0 7.5 4.0 10.0 18.0
TRF600-160-RA 0.160 0.320 250 600 3.0 1.7 1.0 9.5 4.0 7.0 16.0
TRF600-160-R1 0.160 0.320 250 600 3.0 1.7 1.0 9.0 4.0 8.0 17.0
TRF600-250 0.250 0.850 250 600 3.0 2.0 3.0 1.0 1.0 4.3 7.0
TRF600-400 0.400 1.000 60 600 3.0 2.4 3.0 4.0 0.95 1.45 1.90
Part
Number
IH
(A)
IT
(A)
PD Typ
(W)
Typical Time-to-trip
(A) (s)
RMIN
(Ω)
R1MAX
(Ω)
RMAX
(Ω)
Operating
(VDC)
Interrupt
(VRMS)
IMAX*
Interrupt
(A)
VMAX
* 250VAC interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements.
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Product is not currently available in a resistance matched or sorted option.
** R1MAX measured 1 hour post-trip or 24 hours post-reflow at 20°C.
Table T3 Electrical Characteristics for PolySwitch Telecommunications and Networking Devices
2013_CP_S11-Poly-8-TeleNetwork.indd 253 9/3/13 2:59 PM
RoHS Compliant, ELV Compliant
254
11
Notes:
IH : Hold current: maximum current device will pass without interruption in 20°C still air.
IT : Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air.
VMAX Operating : Maximum continuous voltage device can withstand without damage at rated current. This voltage is used for component recognition under UL1434.
VMAX Interrupt : Maximum voltage that can be safely placed across a device in its tripped state. Devices may trip safely under higher level power cross conditions to assist
equipment in meeting the appropriate ITU, UL60950 or GR1089 industry requirements.
IMAX Interrupt : Maximum fault current device can withstand without damage at rated operating voltage. This current is used for component recognition under UL1434.
Devices may trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950 or GR1089 industry requirements.
PD : Power dissipated from device when in the tripped state in 20°C still air.
RMIN : Minimum resistance of device as supplied at 20°C unless otherwise specified.
RMAX : Maximum resistance of device as supplied at 20°C unless otherwise specified.
R1MAX : Maximum resistance measured one hour post-trip or post-reflow at 20°C.
* 250VAC interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements.
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Surface-mount — 600VAC
TS600/TSM600
TS600-170F 0.170 0.400 60 600 3.0 2.5 1.0 10.0 4.0 9.0 18.0
TS600-200F-RA-B-0.5 0.200 0.400 60 600 3.0 2.5 1.0 12.0 4.0 7.5 13.5
TS600-400F 0.400 1.000 60 600 3.0 2.0 3.0 5.0 0.5 1.5 2.0
TSM600-250F 0.250 0.860 250 600 3.0 2.0 3.0 0.8 1.0 3.5 7.0
TSM600-250F-RA 0.250 0.860 250 600 3.0 2.0 3.0 1.0 1.0 3.0 5.0
TSM600-400F 0.400 1.000 250 600 3.0 2.0 3.0 5.0 0.5 1.5 2.0
Part
Number
IH
(A)
IT
(A)
PD Typ
(W)
Typical Time-to-trip
(A) (s)
RMIN
(Ω)
R1MAX
(Ω)
RMAX
(Ω)
Operating
(VDC)
Interrupt
(VRMS)
IMAX*
Interrupt
(A)
VMAX
C
B
D
A
E
Cto
LC
L
Figure T2
C
B
D
A
E
Cto
LC
L
Figure T3
B
AC
Figure T4
C
B
DE
A
Figure T5
B
D
F
A C
E
Figure T6
B
C
E
A
DD
Figure T7
Table T3 Electrical Characteristics for PolySwitch Telecommunications and Networking Devices
Cont’d
Figures T2-T13 Dimension Figures for PolySwitch Telecommunications and Networking Devices
2013_CP_S11-Poly-8-TeleNetwork.indd 254 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 255
11
CB
E
G
E
A
D D
F
Figure T9
C
B
ED
F
A
Figure T8
D
B
C
A
E
Cto
LC
L
Figure T13
D
B
AC
E
Cto
LC
L
Figure T10
D
B
AC
E
Cto
LC
L
Figure T11
AC
E
Cto
LC
L
D
B
Figure T12
Figures T2-T13 Dimension Figures for PolySwitch Telecommunications and Networking Devices
Cont’d
2013_CP_S11-Poly-8-TeleNetwork.indd 255 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
256
11
Table T4 Dimensions & Weights for PolySwitch Telecommunications and Networking Devices
TCF-250V*
TCF250-100T 4.6 4.9 4.6 4.9 2.0 2.3 — — — — — — — — T4 0.24
(0.18) (0.19) (0.18) (0.19) (0.08) (0.09)
TCF250-120T 5.4 5.6 5.4 5.6 2.0 2.3 — — — — — — — — T4 0.28
(0.21) (0.22) (0.21) (0.22) (0.08) (0.09)
TCF250-145T 5.4 5.6 5.4 5.6 2.0 2.5 — — — — — — — — T4 0.28
(0.21) (0.22) (0.21) (0.22) (0.08) (0.10)
TCF250-180 6.9 7.1 6.9 7.1 1.3 1.6 — — — — — — — — T4 0.35
(0.27) (0.28) (0.27) (0.28) (0.05) (0.06)
TRF250-250V*
TRF250-055UT — 4.8 — 9.3 — 3.8 4.7 — 5.0 — — — — T2 0.13
(0.19) (0.37) (0.15) (0.19) (0.20)
TRF250-080T — 5.8 — 9.9 — 4.6 4.7 — 5.0 — — — — T2 0.28
(0.23) (0.39) (0.18) (0.19) (0.20)
TRF250-080U — 4.8 — 9.3 — 3.8 4.7 — 5.0 — — — — T11 0.13
(0.19) (0.37) (0.15) (0.19) (0.20)
TRF250-110U — 5.3 — 9.4 — 3.8 4.7 — 5.0 — — — — T11 0.13
(0.21) (0.37) (0.15) (0.19) (0.20)
TRF250-120 — 6.5 — 11.0 4.6 4.7 — 5.0 — — — — T3 0.38
(0.26) (0.43) (0.18) (0.19) (0.20)
TRF250-120U — 6.0 — 10.0 3.8 4.7 — 5.0 — — — — T10 0.19
(0.24) (0.39) (0.15) (0.19) (0.20)
TRF250-145 — 6.5 — 11.0 4.6 4.7 — 5.0 — — — — T3 0.38
(0.26) (0.43) (0.18) (0.19) (0.20)
TRF250-145U — 6.0 — 10.0 3.8 4.7 — 5.0 — — — — T10 0.19
(0.24) (0.39) (0.15) (0.19) (0.20)
TRF250-183 7.5 10.5 4.1 4.7 5.0 — — — — T2 0.30
(0.29) (0.41) (0.16) (0.19) (0.20)
TRF250-184 7.7 10.5 4.6 4.7 5.0 — — — — T12 0.32
(0.30) (0.41) (0.18) (0.19) (0.20)
TS250/TSL250/TSV250-250V*
TSL250-080F 6.7 7.9 2.7 3.7 4.8 5.3 0.2 0.4 2.5 3.1 — — — — T7 2.80
(0.27) (0.31) (0.11) (0.15) (0.19) (0.21) (0.01) (0.02) (0.10) (0.12)
TS250-130F 8.5 9.4 — 3.4 — 7.4 0.3 3.8 — — — — T5 3.60
(0.34) (0.37) (0.14) (0.29) (0.01) (0.15)
TSV250-130F 6.10 6.90 3.20 0.56 — 1.90 1.60 2.30 T6 2.80
(0.24) (0.27) (0.13) (0.02) (0.08) (0.07) (0.09)
TSV250-184F 6.10 6.90 3.20 0.56 1.90 1.60 2.30 T6 2.80
(0.24) (0.27) (0.13) (0.02) (0.08) (0.07) (0.09)
TRF600-600V
TRF600-150 — 9.0 — 12.5 4.6 4.7 — 5.0 — — 9.0 — — T3 0.37
(0.35) (0.49) (0.18) (0.19) (0.20) (0.35)
TR600-150F-EX 13.5 — 12.6 6.0 4.7 — 5.0 — — — — — T3 0.80
(0.53) (0.50) (0.18) (0.19) (0.20)
TR600-150F-EX-RA-B-0.5 — 13.5 12.6 6.0 4.7 — 5.0 — — — — — T3 0.80
(0.53) (0.50) (0.18) (0.19) (0.20)
TRF600-160 16.0 — 12.6 6.0 4.7 — 5.0 — 10.0 T13 0.90
(0.63) (0.50) (0.24) (0.19) (0.20) (0.39)
TRF600-250 15.0 14.5 4.6 4.7 5.0‡ 10.0 T3 0.87
(0.59) (0.57) (0.18) (0.19) (0.20) (0.39)
TRF600-400 14.8 — 13.1 4.6 4.7 — 5.0 — — — — T13 0.85
(0.58) (0.52) (0.18) (0.19) (0.20)
* 250VAC interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements.
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Indicates dimension is typical, not minimum.
Part Number
A
Min Max Figure
Device Mass (g)
(Only for Reference)
B
Min Max
C
Min Max
D
Min Max
E
Min Max
F
Min Max
G
Min Max
Dimensions in Millimeters (Inches)
2013_CP_S11-Poly-8-TeleNetwork.indd 256 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 257
11
Time–to–Trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00
A
A
B
B
C
D
C
D
Figure T14
TCF250
A = TCF250-180
B = TCF250-145T
C = TCF250-120T
D = TCF250-100T
Time–to–Trip (s)
Fault Current (A)
1000
100
10
1
0.10
0.01
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00
A
A
B
C
D
E
B
C
D
E
Figure T15
TRF250
A = TRF250-180/183/184
B = TRF250-145/145U
C = TRF250-120/120U
D = TRF250-110U/120UT/120T
E = TRF250-080T/080U/080US
Table T4 Dimensions & Weights for PolySwitch Telecommunications and Networking Devices
Cont’d
TS600/TSM600-600V
TS600-170F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 23.6
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TS600-200F-RA 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 23.6
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TS600-400F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 19.8
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TSM600-250F 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
TSM600-250F-RA 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
TSM600-400F 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Part Number
A
Min Max Figure
Device Mass (g)
(Only for Reference)
B
Min Max
C
Min Max
D
Min Max
E
Min Max
F
Min Max
G
Min Max
Dimensions in Millimeters (Inches)
2013_CP_S11-Poly-8-TeleNetwork.indd 257 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
258
11
Time–to–Trip (s)
Fault Current (A)
1000
100
10
1
0.1
0.01
01234567
E
C
B
A
D
E
A
B
C
D
Figure T17
TRF600/TS600/TSM600
A = TRF600-400/TS600-400/
TSM600-400F
B = TRF600-250/TSM600-250F/
TS600-170F/200F
C = TRF600-160
D = TR600-150F-EX
E = TRF600-150
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C)
TCF250*
Terminal Material Nickel-plated Copper Foil
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 1000 hrs
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions
are exceeded.
Physical Characteristics
Environmental Specifications
Table T5 Physical Characteristics and Environmental Specifications for
PolySwitch Telecommunications and Networking Devices
Figures
T14-T17
Typical Time-to-Trip Curves at 20°C for PolySwitch Telecommunications and
Networking Devices
Cont’d
0.00 0.50 1.00 1.50 2.00 2.50 3.00
Time–to–Trip (s)
Fault Current (A)
B
C
D
A
B
DA
C
Figure T16
TS250/TSV250/TSL250
A = TSV250-184F
B = TSV250-130F
C = TS250-130F
D = TSL250-080F
2013_CP_S11-Poly-8-TeleNetwork.indd 258 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 259
11
Terminal Material Tin-plated Brass, Nickel Under-plating
Soldering Characteristics EIC 60008-2-58
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 500 hrs
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TS250/TSV250/TSL250*
Physical Characteristics
Environmental Specifications
* 250VAC interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements.
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Excluding TRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85°C/85% RH or 1000h at 60°C/90% RH.
Lead Material Tin-plated Copper, 22AWG
Insulating Material Cured Epoxy Polymer
Flammability Per IEC 695-2-2 Needle Flame Test for 20s
Soldering Characteristics ANSI/J-STD-002, Category 3
Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: Can Withstand 10 s at 260°C±5°C
Note:
Devices are not intended to be placed through a reflow process.
TRF600†
Physical Characteristics
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 1000 hrs
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C (max), 70% RH (max) devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
Environmental Specifications
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C)
Table T5 Physical Characteristics and Environmental Specifications for
PolySwitch Telecommunications and Networking Devices
Cont’d
Lead Material Tin-plated Copper, 22AWG
Insulating Material Cured Epoxy Polymer
Flammability Per IEC 695-2-2 Needle Flame Test for 20 s
Soldering Characteristics ANSI/J-STD-002, Category 3
Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: Can Withstand 10s at 260°C±5°C
Note: Devices are not intended to be placed through a reflow process.
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 1000 hrs
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TRF250*
Physical Characteristics
Environmental Specifications
2013_CP_S11-Poly-8-TeleNetwork.indd 259 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
260
11
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 1000 hrs
Storage Humidity Per IPC/JEDEC J-STD-020A Level 2a
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215J
Note: Storage conditions: 40°C (max), 70% RH (max) devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
† 600VAC interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Terminal Material Tin-plated Brass
Insulating Material Nylon Resin (UL94V-0), 1000V Dielectric Rating
Flammability IEC 695-2-2 Needle Flame Test for 20 s
Soldering Characteristics EIC60068-2-58, Method 7
Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A
TSM600†
Physical Characteristics
Environmental Specifications
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C)
Table T5 Physical Characteristics and Environmental Specifications for
PolySwitch Telecommunications and Networking Devices
Cont’d
Test Conditions
Passive Aging 60°C, 1000 hrs
85°C, 1000 hrs
Humidity Aging 85°C, 85% RH, 1000 hrs
Thermal Shock 125°C, -55°C (10 Times)
Solvent Resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
Terminal Material Tin-plated Brass
Insulating Material Nylon Resin (UL94V-0), 1000V Dielectric Rating
Flammability IEC 695-2-2 Needle Flame Test for 20 s
Soldering Characteristics ANSI/J-STD-002, Category 3
Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A
TS600†
Physical Characteristics
Environmental Specifications
2013_CP_S11-Poly-8-TeleNetwork.indd 260 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 261
11
Chip* — 250VAC
TCF250
TCF250-100T 2,500 10,000
TCF250-120T 2,500 10,000
TCF250-145T 2,500 10,000
TCF250-180 2,500 10,000 UL
Radial-leaded* — 250VAC
TRF250
TRF250-055UT 500 10,000
TRF250-080U 500 10,000 UL, CSA, TÜV
TRF250-080U-2 1,500 7,500 UL, CSA, TÜV
TRF250-080T 500 10,000 08F UL, CSA, TÜV
TRF250-110U 500 10,000 UL, CSA, TÜV
TRF250-120 500 10,000 20F UL, CSA, TÜV
TRF250-120-2 1,500 7,500 20F UL, CSA, TÜV
TRF250-120T 500 10,000 20F UL, CSA, TÜV
TRF250-120T-2 1,500 7,500 20F UL, CSA, TÜV
TRF250-120U 500 10,000 20F UL, CSA, TÜV
TRF250-120U-2 1,500 7,500 20F UL, CSA, TÜV
TRF250-120UT 500 10,000 20F UL, CSA, TÜV
TRF250-145 500 10,000 45F UL, CSA, TÜV
TRF250-145-2 1,500 7,500 45F UL, CSA, TÜV
TRF250-145-RA 500 10,000 45F UL, CSA, TÜV
TRF250-145U 500 10,000 45F UL, CSA, TÜV
TRF250-145U-2 1,500 7,500 45F UL, CSA, TÜV
TRF250-183 500 10,000 83F UL, CSA, TÜV
TRF250-183-2 1,500 7,500 83F UL, CSA, TÜV
TRF250-184 500 10,000 84F UL, CSA, TÜV
Surface-mount* — 250VAC
TS250/TSL250/TSV250
TSL250-080F-2 1,500 7,500 T08 UL, CSA,TÜV
TS250-130F-2 1,500 7,500 T13 UL, CSA, TÜV
TSV250-130F-2 1,200 6,000 T13V UL, CSA, TÜV
TSV250-184F 2500 10,000 T18V UL
Radial-leaded — 600VAC
TRF600
TRF600-150 500 10,000 150F UL, CSA, TÜV
TRF600-150-2 1,500 7,500 150F UL, CSA, TÜV
TR600-150F-EX 500 10,000 150F UL, CSA
TR600-150F-EX-2 600 3,000 150F UL, CSA
TR600-150F-EX-RA-B-0.5 500 10,000 150F UL, CSA
TRF600-160 500 10,000 160F UL, CSA, TÜV
TRF600-160-2 600 3,000 160F UL, CSA, TÜV
TRF600-250 500 10,000 250F UL, CSA, TÜV
TRF600-400 500 10,000 400F UL, CSA
Surface-mount — 600VAC
TS600/TSM600
TS600-170F-2 300 900 T20 UL, CSA
TS600-200F-RA-2 300 900 T20 UL, CSA
TS600-400F-2 300 900 T40 UL, CSA
TSM600-250F-2 200 1,000 TSM600 UL, CSA
TSM600-250F-RA-2 200 1,000 TSM600 UL, CSA
TSM600-400F-2 200 1,000 TSM600 UL
Part Number
Bag
Quantity
Tape and Reel
Quantity
Standard Package
Quantity Part Marking Agency Recognition
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements.
† 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements.
Table T6
Packaging and Marking Information for PolySwitch Telecommunications
and Networking Devices
2013_CP_S11-Poly-8-TeleNetwork.indd 261 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
262
11
Solder Reflow and Rework Recommendations for PolySwitch Telecommunications Surface-Mount
Devices
Solder Reflow
• Recommended reflow method: IR, vapor phase oven, hot air oven.
Surface-mount devices are not intended to be wave soldered to the bottom side of the board.
Recommended maximum paste thickness of 0.25mm (0.010in).
Devices can be cleaned using standard industry methods and solvents.
Rework
• If a device is removed from the board, it should be discarded and replaced with a new device.
Profile Feature Pb-Free Assembly
Average ramp up rate (TsMAX to Tp) 3°C/s max
Preheat
• Temperature min (TsMIN) 150°C
• Temperature max (TsMAX) 200°C
• Time (tsMIN to tsMAX) 60-180 s
Time maintained above:
• Temperature (TL) 217°C
• Time (tL) 60-150 s
Peak/Classification temperature (Tp) 260°C
Time within 5°C of actual peak temperature
Time (tp) 20-40 s
Ramp down rate 6°C/s max
Time 25°C to peak temperature 8min max
Critical Zone
TL to Tp
Ramp Up
t 25˚C to Peak
Reflow Profile Time
Ramp Down
ts
Preheat
TsMAX
TL
Tp
tp
25
TsMIN
tL
Temperature
Figure T21
Note: All temperatures refer to topside of the package, measured on the package
body surface.
Agency Recognition for PolySwitch Telecommunications and Networking Devices
UL File # E74889
CSA File # 78165C
TÜV Per IEC60730-1 Certificate # for individual products available upon request.
Device A B C D E F G Figure
TS250 (All) 4.60 1.80 6.10 T18
(0.180) (0.070) (0.240)
TSV250 (All) 2.29 2.41 6.35 3.43 T19
(0.090) (0.095) (0.250) (0.135)
TSL250 (All) 3.60 1.80 5.50 T18
(0.140) (0.070) (0.220)
TS600 (All) 10.42 3.30 3.35 T18
(0.410) (0.130) (0.132)
TSM600 (All) 5.20 17.80 5.54 6.75 2.08 3.12 8.39 T20
(0.205) (0.701) (0.218) (0.266) (0.082) (0.123) (0.331)
A
BCB
Figure T18
A
A
B B
C
D
Figure T19
A
B
C D
G
E
F
Figure T20
Table T7 Recommended Pad Layouts for Surface-mount PolySwitch Telecommunications and
Networking Devices in Millimeters (Inches) Nominal
2013_CP_S11-Poly-8-TeleNetwork.indd 262 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 263
11
Dimension
Description EIA Mark IEC Mark Dimension (mm) Tolerance
Carrier Tape Width W W 18 -0.5/+1.0
Hold Down Tape Width W4 W0 5 Min
Top Distance between Tape Edges W6 W2 3 Max
Sprocket Hole Position W5 W1 9 -0.5/+0.75
Sprocket Hole Diameter D0 D0 4 ±0.2
Abcissa to Plane (Straight Lead) H H 18.5 ±3.0
Abcissa to Plane (Kinked Lead)* H0 H0 16 -0.5/+0.6
Abcissa to Top H1 H1 32.2 Max
Overall Width with Lead Protrusion C1 43.2 Max
Overall Width without Lead Protrusion C2 42.5 Max
Lead Protrusion L1 I1 1.0 Max
Protrusion of Cut-out L L 11 Max
Protrusion beyond Hold Down Tape I2 I2 Not Specified
Sprocket Hole Pitch P0 P0 12.7 ±0.3
Device Pitch (TRF250 and TRF600-150) 12.7
Device Pitch (TRF600-160 - TRF600-400) 25.4
Pitch Tolerance 20 Consecutive ±1
Tape Thickness t t 0.9 Max
Tape Thickness with Splice* t1 2.0 Max
Splice Sprocket Hole Alignment 0 ±0.3
Body Lateral Deviation Dh Dh 0 ±1.0
Body Tape Plane Deviation Dp Dp 0 ±1.3
Lead Spacing Plane Deviation DP1 P1 0 ±0.7
Lead Spacing* F F 5.08 ±0.6
Reel Width w2 w 56 Max
Reel Diameter a d 370 Max
Space between Flanges Less Device w1 4.75 ±3.25
Arbor Hole Diameter c f 26 ±12.0
Core Diameter n h 80 Max
Box 56/372/372 Max
Consecutive Missing Pieces* 3 Max
Empty Places per Reel* Not Specified
* Differs from EIA specification.
TRF250/TRF600 devices are available in tape and reel packaging per EIA 468-B standard. See Figures T23 and T24 for details.
Table T8 TRF250/TRF600 Tape and Reel Specifications for
PolySwitch Telecommunications and Networking Device
Wave Soldering and Rework Recommendations for PolySwitch Telecommunications Radial-Leaded
Devices
Recommended Wave Soldering
• Soldering temperature profile
Temperature characteristic at component terminal with dual
wave soldering
Rework
• If a device is removed from the board, it should be discarded
and replaced with a new device
300
250
200
150
100
50
00 50
10s
245˚C ... 260˚C
100˚C ... 130˚C
Forced cooling
100 150 200 250
Temperature (˚C)
Time (s)
Figure T22
2013_CP_S11-Poly-8-TeleNetwork.indd 263 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
264
11
w1
n
a
c
w2
Cross Section
Direction of
Unreeling
Reel
Tape
Upper Side
Lower Side
Optional Shape: Circular or Polygonal
Figure T24 Reel Dimensions for PolySwitch Telecommunications Radial-Leaded Devices
Dh
H1P1
W4
H0
H1
C1
C2
F
AB
Reference Plane
Direction of Unreeling
Cross section A-B
W5
H
W
t
P0D0
I2
L
L1
DhDpDp
Figure T23 EIA Referenced Taped Component Dimensions for PolySwitch Telecommunications
Radial-Leaded Devices
2013_CP_S11-Poly-8-TeleNetwork.indd 264 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 265
11
Carrier Tape Width W 16 ±0.30 16.0 ±0.30 16 ±0.30
Sprocket Hole Pitch P0 4.0 ±0.10 4.0 ±0.10 4.0 ±0.10
P1 12.0 ±0.10 8.0 ±0.10 8.0 ±0.10
P2 2.0 ±0.10 2.0 ±0.10 2.0 ±0.10
A0 6.9 ±0.23 5.5 ±0.10 5.5 ±0.10
B0 9.6 ±0.15 6.2 ±0.10 7.9 ±0.10
B1 max 12.1 8.0 9.2
Sprocket Hole Diameter D0 1.5 -0/+0.1 1.55 ±0.05 1.55 ±0.05
F 7.5 ±0.10 7.5 ±0.10 7.5 ±0.10
E1 1.75 ±0.10 1.75 ±0.10 1.75 ±0.10
E2 min 14.25
Tape Thickness T max 0.4 0.45 0.35
Tape Thickness With T1 max 0.1 0.1 0.1
Splice Cover Tape Thickness K0 3.4 ±0.15 7.0 ±0.10 3.70 ±0.10
Leader min 300 390 390
Trailer min 300 160 160
Reel Dimensions
Reel Diameter A max 340 340 340
Core Diameter N min 50 50 50
Space between Flanges-less Device W1 16.4 -0/+2.0 16.4 -0/+2.0 16.4 -0/+2.0
Reel Width W2 max 22.4 22.4 22.4
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.
EIA Mark
TS250
Dimension (mm) Tolerance (mm)
TSV250
Dimension (mm) Tolerance (mm)
TSL250
Dimension (mm) Tolerance (mm)
Dimension
Description
TS250/TSL250/TSV250
Table T9 TS Tape and Reel Specifications for PolySwitchTelecommunications and
Networking Devices
Dimension
Description EIA Mark Dimension (mm) Tolerance
Carrier Tape Width W 32 ±0.3
Sprocket Hole Pitch P0 4.0 ±0.1
P1 16 ±0.1
P2 2.0 ±0.1
A0 10 ±0.1
B0 19.2 ±0.1
B1 max 21.6
Sprocket Hole Diameter D0 1.5 -0/+1.0
F 14.2 ±0.1
E1 1.75 ±0.1
E2 min 28.4 ±0.1
Tape Thickness T max 0.50 ±0.5
Tape Thickness with Splice T1 max 0.1
K0 13.2 ±0.1
Leader min 390
Trailer min 160
Reel Dimensions
Reel Diameter A max 360
Core Diameter N min 50
Space between Flanges-less Device W1 32.4 -0/+2.0
Reel Width W2 max 40
TS600
2013_CP_S11-Poly-8-TeleNetwork.indd 265 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
266
11
P0
E1
E2
FW
P2
D0
A0
B0
P1
B1
T1
K0
T
Cover Tape
Embossment
Center Lines
of Cavity
A
Cover Tape
Embossed Cavity
Carrier Tape
N (Hub Dia.)
W2 (Measured at Hub)
W1 (Measured at Hub)
Figure T25 EIA Referenced Taped Component Dimensions for PolySwitch Telecommunications and
Networking Devices
Figure T26 EIA Referenced Reel Dimensions for PolySwitch Telecommunications and Networking
Devices
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.
Table T9 TS Tape and Reel Specifications for PolySwitch Telecommunications and Networking
Devices
Cont’d
Dimension
Description EIA Mark Dimension (mm) Tolerance
Carrier Tape Width W 32 ±0.3
Sprocket Hole Pitch P0 4.0 ±0.1
P1 24 ±0.1
P2 2.0 ±0.1
A0 11.2 ±0.1
B0 17.8 ±0.1
B1 max 23.45
Sprocket Hole Diameter D 1.5 -0/+1.0
F 14.2 ±0.1
E1 1.74 ±0.1
E2 max 28.4 ±0.1
Tape Thickness T max 0.5 ±0.5
Tape Thickness with Splice T1 max 0.1
K0 11.9 ±0.1
Leader min 390
Trailer min 160
Reel Dimensions
Reel Diameter A max 360
Core Diameter N min 50
Space between Flanges-less Device W1 32.4 -0/+2.0
Reel Width W2 max 40
TSM600
2013_CP_S11-Poly-8-TeleNetwork.indd 266 8/3/13 10:41 AM
PolySwitch Resettable Devices – Telecommunications & Networking Devices
RoHS Compliant, ELV Compliant 267
11
PolySwitch Telecommunications and Networking Resistance-Sorted and Resistance-Matched Devices
Resistance-sorted devices (part number suffix “Rx”, where x = 1, 2, A, B, C, F, etc.) are supplied with resistance values that are within
specified segments of the device’s full range of resistance.
Feature
• Narrow resistance range.
Benefits
• Can help provide greater flexibility for design engineers.
• Lower resistance devices can help provide increased loop length on line card designs.
• Higher resistance devices may help provide greater protection by offering faster time-to-trip.
Resistance-sorted Devices
Most TCF, TRF and TS devices are available in resistance-sorted and/or resistance-matched versions.
Resistance-matched devices are supplied such that all parts in one particular package (or reel) are within 0.5Ω of each other
(1.0Ω for TRF250-080T devices). Individual matched packages are supplied from the full resistance range of the specified device.
Feature
• Tighter resistance balance between any two parts in a package.
Benefits
• Resistance-matched devices may help reduce the tip-ring resistance differential, reducing the possibility of line imbalance.
Resistance-matched Devices
Part Numbering System for PolySwitch Radial-Leaded Telecommunications and Networking Devices
TRF*250 -120 T -RA -B-0.5 -2
Packaging
2 = Tape and Reel
0.130 = Special Lead Length in Inches
(Blank) = Bulk
B-x.x = Resistance Matched in Bins of x.xΩ (Optional)
Rx = Resistance Range (Optional)
Modifier (Optional)
U = Uncoated
S = Straight Lead
T = Fast Trip Device
Hold Current (mA)
Product Series (TRF250, TRF600)
* F = RoHS compliant, ELV compliant
Part Numbering System for PolySwitch Surface-mount Telecommunications and Networking Devices
TSx -200 F -RA -B-0.5 -2
Packaging
2 = Tape and Reel
(Blank) = Bulk
B-x.x = Resistance Matched in Bins of x.xΩ (Optional)
Rx = Resistance Range (Optional)
F = RoHS Compliant, ELV Compliant
Hold Current (mA)
Product Series (TS250, TSV250, TSL250, TS600, TSM600)
2013_CP_S11-Poly-8-TeleNetwork.indd 267 8/3/13 10:41 AM
RoHS Compliant, ELV Compliant
268
11
Part Numbering System for Chip PolySwitch Telecommunications and Networking Devices
TCF*250 -120 T -RA -B-0.5
B-x.x = Resistance Matched in Bins of x.xΩ (Optional)
Rx = Resistance Range (Optional)
Modifier (Optional)
T = Fast Trip Device
Hold Current (mA)
Product Series
* F = RoHS compliant, ELV compliant
Warning :
• Users should independently evaluate the suitability of and test each product selected for their own application.
• Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.
• These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should
not be used when repeated fault conditions or prolonged trip events are anticipated.
Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the
devices.
• Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal and
mechanical procedures for electronic components.
• PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited,
for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.
• Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device.
2013_CP_S11-Poly-8-TeleNetwork.indd 268 8/3/13 10:41 AM
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
TRF250-120US-2