PLA140 Single-Pole Normally Open OptoMOS(R) Relay INTEGRATED CIRCUITS DIVISION Parameter Blocking Voltage Load Current On-Resistance (max) Rating 400 250 8 Units VP mArms / mADC Features Description The PLA140 is a single-pole normally open (1-Form-A) Solid State Relay that uses optically coupled MOSFET technology to provide 3750Vrms of input-to-output isolation. MOSFET output switches, which use IXYS Integrated Circuits Division's patented OptoMOS architecture, are controlled by a highly efficient GaAIAs infrared LED. * Low On-Resistance, High Current Handling * Low Drive Power Requirements (TTL/CMOS Compatible) * 3750Vrms Input/Output Isolation * High Reliability * VDE Compatible * FCC Compatible * Arc-Free With No Snubbing Circuits * No EMI/RFI Generation * Machine Insertable, Wave Solderable * Small 6-Pin Package * Surface Mount Tape & Reel Version Available The PLA140's combination of low on-resistance and high load current handling makes it suitable for a variety of industrial applications. Because Solid State Relays like the PLA140 have no moving parts, they offer faster, bounce-free switching in a more compact surface mount or though hole package than traditional electromechanical relays. Applications * Telecommunications * Telecomm Switching * Hook Switch * Instrumentation * Multiplexers * Data Acquisition * Electronic Switching * I/O Subsystems * Meters (Watt-Hour, Water, Gas) * Medical Equipment--Patient/Equipment Isolation * Security * Aerospace * Industrial Controls * Automotive Approvals * UL Certified Component: File E76270 * CSA Certified Component: Certificate 1175739 * Certified to EN60950 TUV Certificate B 09 07 49410 004 Ordering Information Part Number PLA140 PLA140S PLA140STR Switching Characteristics of Normally Open Devices Pin Configuration AC/DC Configuration 1 + Control - Control Do Not Use 6 2 5 3 4 Form-A Load Do Not Use IF Load 90% DC Only Configuration + Control - Control Do Not Use Pb DS-PLA140-R08 Description 6-Pin DIP (50/Tube) 6-Pin Surface Mount (50/Tube) 6-Pin Surface Mount (1,000/Reel) 1 6 2 5 3 4 + Load 10% ILOAD - Load ton toff e3 www.ixysic.com 1 INTEGRATED CIRCUITS DIVISION PLA140 Absolute Maximum Ratings @ 25C Parameter Blocking Voltage Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Total Power Dissipation 2 Isolation Voltage, Input to Output Operational Temperature Storage Temperature 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Ratings 400 5 50 1 150 800 3750 -40 to +85 -40 to +125 Units VP V mA A mW mW Vrms C C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Electrical Characteristics @ 25C Parameter Output Characteristics Load Current (Continuous) AC/DC Configuration DC Configuration Peak Load Current On-Resistance AC/DC Configuration DC Configuration Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics Input Control Current to Activate Input Control Current to Deactivate Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance 2 Conditions Symbol Min Typ Max Units IF=5mA IL - - 250 350 500 mArms / mADC mADC mAP IF=5mA , t=10ms ILPK 5.5 1.5 - 8 3 1 ILEAK - IF=0mA , VL=50V, f=1MHz ton toff COUT - 0.4 0.19 18 3 1 - IL=250mA IF=5mA VR=5V IF IF VF IR 0.2 0.9 - 0.46 0.44 1.2 - 5 1.4 10 mA mA V A - CI/O - 3 - pF IF=5mA , IL=250mA IF=5mA , IL=350mA VL=400VP IF=5mA, VL=10V RON www.ixysic.com A ms pF R08 INTEGRATED CIRCUITS DIVISION PLA140 PERFORMANCE DATA* 30 Typical LED Forward Voltage Drop (N=50, IF=5mA) Typical IF for Switch Operation (IL=250mA) 20 Typical On-Resistance Distribution (N=50, IF=5mA, IL=250mA) 20 20 15 10 Device Count (N) Device Count (N) Device Count (N) 25 15 10 5 15 10 5 5 1.235 1.240 1.245 1.250 1.255 1.260 1.265 LED Forward Voltage (V) 0.28 0.34 0.40 0.46 0.52 0.58 0.64 0.70 LED Current (mA) Typical Turn-On Time (N=50, IF=5mA, IL=100mA) Typical Turn-Off Time (N=50, IF=5mA, IL=100mA) 25 15 10 20 15 10 0 0 0.675 0.750 0.825 0.900 0.975 1.050 1.125 1.200 Turn-On Time (ms) 0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.27 Turn-Off Time (ms) Typical LED Forward Voltage Drop vs. Temperature Typical Turn-On Time vs. LED Forward Current (IL=100mA) 1.6 1.6 1.4 1.3 1.1 -40 0.60 0.6 0.4 0 20 40 60 Temperature (C) 80 100 0 Typical IF for Switch Operation vs. Temperature (IL=100mA) 1.4 10 20 30 LED Current (mA) 40 5 448 454 460 466 472 478 Blocking Voltage (VP) 484 Typical Turn-Off Time vs. LED Forward Current (IL=100mA) 0.24 0.22 0.20 0.18 0 50 Typical Turn-On Time vs. Temperature (IF=5mA, IL=100mA) 0.26 1.3 Turn-On Time (ms) 0.56 0.54 0.52 0.50 0.48 0.46 1.2 1.1 1.0 0.9 0.8 0.7 0 20 40 60 Temperature (C) 80 100 0.5 -40 10 20 30 LED Current (mA) 40 50 Typical Turn-Off Time vs. Temperature (IF=5mA, IL=100mA) 0.24 0.22 0.20 0.18 0.16 0.6 -20 10 0.16 0.0 -20 5.4 0.2 0.58 0.44 -40 0.8 Turn-Off Time (ms) 1.2 IF=50mA IF=20mA IF=10mA IF=5mA 1.0 5.3 15 0.26 1.2 4.9 5.0 5.1 5.2 On-Resistance (:) Typical Blocking Voltage Distribution (N=50, IF=0mA) 442 Turn-Off Time (ms) 1.5 4.8 0 1.4 Turn-On Time (ms) LED Forward Voltage (V) 20 5 5 4.7 Device Count (N) 20 Device Count (N) Device Count (N) 25 LED Current (mA) 0 0 0 -20 0 20 40 60 Temperature (C) 80 100 0.14 -40 -20 0 20 40 60 Temperature (C) 80 100 *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R08 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION PLA140 PERFORMANCE DATA* 0.3 8 0.2 7 6 5 4 3 -40 -20 0 20 40 60 Temperature (C) 80 0.1 0.0 -0.1 225 200 175 150 125 -0.3 -1.5 100 100 -1.0 -0.5 0.0 0.5 Load Voltage (V) 1.0 -40 1.5 0.35 350 0.30 325 1.6 1.4 0.20 0.15 0.10 1.2 0.05 1.0 -40 0.00 -20 0 20 40 60 Temperature (C) 80 Load Current (mA) 1.8 500 70 Leakage Current (nA) 80 480 470 460 450 440 -40 -20 0 20 40 60 Temperature (C) 80 100 80 100 300 275 250 225 200 150 510 490 20 40 60 Temperature (C) 175 0.0 100 0 375 0.1 0.2 0.3 0.4 Load Voltage (V) 0.5 -40 0.6 Typical Leakage vs. Temperature Measured Across Pins 4&6 (VL=400V) -20 0 20 40 60 Temperature (C) 80 100 10s 100s Energy Rating Curve 1.2 Load Current (A) Load Current (A) 0.40 2.2 0.25 -20 Maximum Load Current vs. Temperature - DC-Only Configuration (IF=5mA) Typical Load Current vs. Load Voltage DC-Only Configuration (IF=5mA) 2.4 2.0 Maximum Load Current vs. Temperature - AC/DC Configuration (IF=5mA) 250 Typical Blocking Voltage vs. Temperature Blocking Voltage (VP) 275 -0.2 Typical On-Resistance vs. Temperature DC-Only Configuration (IF=5mA, IL=100mA) On-Resistance (:) Typical Load Current vs. Load Voltage AC/DC Configuration (IF=5mA) Load Current (mA) 9 Load Current (A) On-Resistance (:) Typical On-Resistance vs. Temperature AC/DC Configuration (IF=5mA, IL=100mA) 60 50 40 30 20 1.0 0.8 0.6 0.4 10 0 -40 -20 0 20 40 60 Temperature (C) 80 100 0.2 10Ps 100Ps 1ms 10ms 100ms Time 1s *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.ixysic.com R08 INTEGRATED CIRCUITS DIVISION PLA140 Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Rating PLA140 / PLA140S MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device Maximum Temperature x Time PLA140 / PLA140S 250C for 30 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. Pb R08 e3 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION PLA140 MECHANICAL DIMENSIONS PLA140 8.382 0.381 (0.330 0.015) PCB Hole Pattern 7.239 TYP (0.285 TYP) 2.54 0.127 (0.100 0.005) 6 - 0.800 DIA. (6 - 0.031 DIA.) 9.144 0.508 (0.360 0.020) 6.350 0.127 (0.250 0.005) 2.540 0.127 (0.100 0.005) 7.620 0.127 (0.300 0.005) Pin 1 7.620 0.254 (0.300 0.010) 1.651 0.254 (0.065 0.010) 3.302 0.051 (0.130 0.002) 0.254 0.0127 (0.010 0.0005) 6.350 0.127 (0.250 0.005) 5.080 0.127 (0.200 0.005) 4.064 TYP (0.160 TYP) Dimensions mm (inches) 0.457 0.076 (0.018 0.003) PLA140S 8.382 0.381 (0.330 0.015) 9.524 0.508 (0.375 0.020) Pin 1 0.635 0.127 (0.025 0.005) PCB Land Pattern 2.54 0.127 (0.100 0.005) 2.54 (0.10) 6.350 0.127 (0.250 0.005) 0.457 0.076 (0.018 0.003) 1.651 0.254 (0.065 0.010) 7.620 0.254 (0.300 0.010) 0.254 0.0127 (0.010 0.0005) 8.90 (0.3503) 1.65 (0.0649) 0.65 (0.0255) 3.302 0.051 (0.130 0.002) 4.445 0.254 (0.175 0.010) Dimensions mm (inches) 1.651 0.254 (0.065 0.010) 6 www.ixysic.com R08 INTEGRATED CIRCUITS DIVISION PLA140 PLA140STR Tape & Reel 330.2 Dia (13.00 Dia) Top Cover Tape Thickness 0.102 Max (0.004 Max) W=16.00 (0.63) B0 = 10.10 (0.398) K0 = 4.90 (0.19) K1 = 3.80 (0.15) P = 12.00 (0.472) User Direction of Feed Embossed Carrier Embossment A0 = 10.10 (0.398) Dimensions mm (inches) NOTES: 1. All dimensions carry tolerances of EIA Standard 481-2 2. The tape complies with all "Notes" for constant dimensions listed on page 5 of EIA-481-2 For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division's Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division's product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 7 Specification: DS-PLA140-R08 (c)Copyright 2012, IXYS Integrated Circuits Division OptoMOS(R) is a registered trademark of IXYS Integrated Circuits Division All rights reserved. Printed in USA. 12/22/2012 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: IXYS: PLA140 PLA140L PLA140LS PLA140STR PLA140S PLA140LSTR