Dimensions: Inches (Millimeters)
Tolerance: ±0.010 (0.25) unless specified otherwise
MHJ Series SO 3kV Interface Transformer Modules
05906NEleveLnoitalusnIdecrofnieRhtiwylpmocseludoMVk3
rebmuNtraP L
P
)niMHm( oitaRsnruT %1± L
L
)xaMHµ(
^
I
CD
)Am( C
C
)xaMFp( R
UC
P)smhO( R
UC
S)smhO( V
P
)smrV( citamehcS
XXX-1B002-JHM 03 :1:1 1:1 01 4 57 7.1 9.1 0003 A
XXX-1B042-JHM03:1:1 2:2 014577.17.30003A
XXX-1B032-JHM 03 :1:1 5.2:5.2 01 4 57 7.1 4.4 0003 A
ekohCdauQedoMnommoC
xiffuS+N/PcisaB 205-1B042-JHM:elpmaxE( L
N
)Hµ( R
UC
)smhO(
000- ekohCoN
074-744.0
101- 001 6.0
105-0054.0
205- 0005 1.1
321-000218.1
Electrical Specifications @ 25°C Turns Ratio: Bold = IC side windings
Suggested Pad Layout
Test Conditions:
1. Polarity and Turns Ratio: w1 : w2 : w3 : w4 ±1%
2. Inductance: 30mH Minimum, line side windings (w3+w4) in series @ 10kHz, 100mV
3. Leakage Inductance: 10µH Max. @ 100kHz, 100mV
4. Quad Choke Inductance: 100kHz, 20mV
5. Winding Capacitance: CW 150pF Max. (w3+w4)
6. Coupling Capacitance: CC 75pF Max. (w3+w4 to w1+w2) @ 10kHz, 100mV
7. High Voltage Test: 3kV, 1 minute U(w3+w4 to w1+w2)
High Voltage Pulse Test: UPULSE (w3+w4 to w1+w2); 10kVOP for 1,2µs/50µs wave form
UPULSE (w3+w4 to w1+w2); 10kVOP for 10µs/700µs wave form
MHJ Module
0° - 8°
Surface Coplanarity will be 0.004(0.10) maximum
0.059
(1.50)
0.100
(2.54)
0.756
(19.2) 0.520
(13.2)
0.700
(17.78)
Pins - 0.012 x 0.020 (0.3 x 0.5)
0.394
(10.0) 0.346
(8.8)
0.945
(24.00)
0.717
(18.2)
0.122
(3.11)
0.630
(16.0)
7 x 0.100 (2,54)
0.020
(0.50)
T ALEMA IN
WK/YR
Part Number
W1
W1
W2
W2
W3
W3
W4
W4
AICLine
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
Schematic
Features
excellent output characteristics ensure compliance with CCITT.I.430
pulse waveform template when used with recommended IC pairing
SMD modules are designed for pick and place compatability
excellent and consistent balance between windings
modular design maximizes suppression effectivity and transmission
properties
full compatibility with all common IC's
manufactured in ISO-9001:2000, TS-16949:2002 and
ISO-14001:2001 certified Talema facility
fully RoHS compliant and meets lead free reflow level
J-STD-020C
operating temperature: -40° to 85°C
storage temperature: -40 to +125°C
SO Transformer modules comply with Reinforced Insulation Level
EN60950:1992/A4: 1997, para. 2.9.4.4 when tested in accordance with 6.4.1
Germany: Int.+4989-841 00-0 • Ireland: Int.+35 374 - 954 8666 • Czech Rep: Int.+420 377 - 338 351 • India: Int.+91 427 - 244 1325
http://www.talema-nuvotem.com (10-06) Communications \ MHJ