K M Y Drawing No: RAC−K−HTS−0006 /7
Title: CHIP ATTENUATORS
RAC101A Page: 4/6
Product specification contained in this specification are subject to change at any time without notice.
If you have any questions or a Purchasing Specification for any quality agreement is necessary, please contact our sales staff.
Issue: KAMAYA ELECTRIC CO., LTD. Research & Development Department HOKKAIDO Research center Last update: 2012.10.9
Table−4(2)
No. Test items Condition of test Performance requirements
Test cycle: 5 cycles for duty cycle as specified
below.
Step Temperature (°C) Time (min)
1 Room temp. 2∼3
2 −55±3 30
3 Room temp. 2∼3
4 125±2 30
7 Temperature cycling
Leaving at the room temp. for 30 min. or more,
and then measure the attenuation factor.
0.5dB ∼ 2dB: Within ±0.1%
3dB ∼ 5dB: Within ±0.2%
6dB ∼ 10dB: Within ±0.3%
No evidence of appearance damage.
The test substrate: Glass fabric based epoxy
resin. t: 1.6 mm
Test temp.: 125 °C ± 2 °C
+48
Test period: 1,000 h
0
8 Dry heat
Leaving at the room temp. for 2h or more, and
then measure the attenuation factor.
0.5dB ∼ 2dB: Within ±0.1%
3dB ∼ 5dB: Within ±0.2%
6dB ∼ 10dB: Within ±0.3%
No evidence of appearance damage.
The test substrate: Glass fabric based epoxy
resin. t: 1.6 mm
Test temp.: −55 °C ± 3 °C
+48
Test period: 1,000 h
0
9 Cold
Leaving at the room temp. for 2h or more, and
then measure the attenuation factor.
0.5dB ∼ 2dB: Within ±0.1%
3dB ∼ 5dB: Within ±0.2%
6dB ∼ 10dB: Within ±0.3%
No evidence of appearance damage.
The test substrate: Glass fabric based epoxy
resin. t: 1.6 mm
Test circuit: See No. 1.
Test temp. & relative humidity:
60 °C ± 2 °C & 90 %∼95 %
Test voltage: Cycle of 1 h 30 min. ″ON″ and
30 min. ″OFF″ at dc rated voltage.
+48
Test period: 1,000 h
0
0.5dB ∼ 2dB: Within ±0.1%
3dB ∼ 5dB: Within ±0.2%
6dB ∼ 10dB: Within ±0.3%
No evidence of appearance damage.
10 Load life in humidity
Leaving at the room temp. for 2h or more, and
then measure the attenuation factor.
The test substrate: Glass fabric based epoxy
resin. t: 1.6 mm
Test circuit: See No. 1.
Test temp. : 85 °C ± 2 °C
Test voltage: Cycle of 1 h 30 min. ″ON″and
30 min. ″OFF″ at dc rated voltage.
+48
Test period: 1,000 h
0
0.5dB ∼ 2dB: Within ±0.1%
3dB ∼ 5dB: Within ±0.2%
6dB ∼ 10dB: Within ±0.3%
No evidence of appearance damage.
11 Load life
Leaving at the room temp. for 2h or more, and
then measure the attenuation factor.