Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
697
800-262-IDEC (4332) • USA & Canada
ø22mm - TW Series
Switches & Pilot Devices
1904032203
Specifications
Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
Approvals
File No. E68961 File No. LR21451 Certificate No.
2030010305027380
Registration No: J9551802 (E-Stops)
Registration No: J9551803 (All other switches)
Registration No: J9551804 (Pilot Lights)
CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with
integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot
lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Operating Temperature Operation: –25 to +50°C (without freezing), Storage: –40 to +80°C (without freezing)
Vibration Resistance 5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6
Shock Resistance 1000m/sec2 (100g) conforming to IEC6068-2-7
Electric Shock Protection Class 2 conforming to IEC60664-7
Degree of Protection
(conforming to IEC60529)
(conforming to NEMA ICS6-110)
IP65 from front of the panel; (IP54 for key switches)
IP20 (Type HW-U contact block)
Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches)
Mechanical Life Momentary pushbuttons: 5,000,000 (1800 operations per hour)
All other switches: 500,000
Pollution Degree (conforming to IEC60947-1) 3
Rated Operational Characteristics
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
Rated Insulation Voltage 600V
Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1
Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit
Rated Thermal Current 10 Amp
Minimum Switching Capacity 5 mA at 3V AC/DC
Contact Operation Slow break NC or slow make NO, self-cleaning
Recommended Terminal Torque
Unit Wire Number of Wires Recommended Tightening
Torque (Nm) Terminal Screw
HW-U Contact Block
Crimping Terminal 2 1.0 to 1.3
M3.5
Solid Wire ø0.5 to 1.6 mm (AWG14 to 22) 2 1.0 to 1.3
ø1.7 to 2.0 mm (AWG12) 1 1.2 to 1.3
Stranded Wire 0.3 to 2.0 mm2 (AWG14 to 22) 2 1.0 to 1.3
2.1 to 3.5 mm2 (AWG12) 1 1.2 to 1.3
Illuminated Unit (*1)
Crimping Terminal
2 1.0 to 1.3 M3.5
Solid Wire ø0.5 to 1.6 mm (AWG14 to 22)
Stranded Wire 0.3 to 2.0 mm (AWG14 to 22)
Applicable Wire Size Pilot Light
Crimping Terminal
2
0.6 to 1.0 (M3.0)
1.0 to 1.3 (M3.5)
Solid Wire ø0.5 to 1.6 mm (AWG14 to 22)
Stranded Wire ø0.3 to 2.0 mm (AWG14 to 22)
1. * refers to the lamp terminals of the illuminated push buttons and selector switches.
External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1
Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Contact Resistance Initial contact resistance of 50mΩ or less
Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB)
Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
Lamp Ratings LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max
Horsepower Rating 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor)
Contact Material Silver
Contact Ratings
Pushbuttons
Illuminated Pushbuttons
Selector Switches
Illuminated Selector Switches
Pushbutton Selectors
Contact Block Type HW-U
Rated Insulation Voltage 600V
Rated Continuous Current 10A
Contact Ratings by Utilization Category
IEC 60947-5-1
AC-15 (A600)
DC-13 (P600)
Characteristics
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
Operational Current
AC50/60Hz
AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A
DC
DC-12 Control of resistive loads and solid state loads 10A 5A — 2.2A 1.1A —
DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A —