Removable Lock-Down Door
When Activated, Locks Push
Button and Contacts in the
Powered Position.
Isolated Input and
Output Terminals
Separates Control
Circuits from Load Circuits.
F
l
ag In
d
icator
Shows Relay Status
in Manual or Powered
Condition.
Slim Design
Minimizes Space
on DIN Rail.
Finger-Safe
Protects Operators
from Live Circuits.
Color-Coded Push Button
Allows Manual Operation
of Relay. AC Coils Red or
DC Coils Blue.
2-Way Side or DIN
Rail Mounting System
Retrofits Existing Panel
Mounting and 35mm DIN Rail.
Mating Hold-Down
Clip Available
Safely Secures
Relay to Socket.
Finger Grip Cover
Easy Removal of
Relay from Socket.
Contact Viewing Window
Shows Position of Contacts.
Bi-Polar LED Status Lamp
Shows Coil “ON” or “OFF” Status.
I.D. Tag/Write-On
Plastic Label
Used for Identification
of Relays in Multi-Relay
Circuits.
Module Compatible
Allows for Optional
Protection or LED Modules
to be Used With Sockets.
Internal Coil Bus Jumper System
Allows Connection to Adjacent
Sockets Without Additional Wiring.
I.D. Tag/Write-On
Plastic Label
Used to Match Wire
Identification Tags with
Socket Connections.
Gold Flashed Contacts
Prevents Premature Oxidation
and Increases Shelf-life.
www.magnecraft.com 847-441-2540
SECTION 1
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
Advantages of a Full Featured, Octal 700 Series Relay
Octal style mounting is a robust and
historically proven form of mounting electrical
components. This interface provides excellent
structural support that has been recognized
by the electrical industry for over half a
century. Magnecraft has combined this
historical platform with modern features
and performance. The 750 Octal relays
will mate will all forms of the 8 and 11 pin
octal sockets. This package provides all the
performance and features of Magnecrafts
700 series relay, while using a mounting
platform that the customer has grown
accustomed to.
• Offers a “one stop solution” for
your power management
system.
• Several Contact congurations
and materials to meet your
individual needs.
• Plug-In switching capabilities
from 10 mA to 16 Amps.
• Several Feature Code and
Operation combinations avail-
able for all budgets.
• Ejector clips, ribbed relay hous-
ings
and space-saving sockets
allow for easy removal from
crowded DIN rails.
• Color and appearance designed
for high visibility in all environ-
ments.
• Wiring diagrams include NEMA
and IEC standards.
• Engineering availability allows
for customized relay solutions.
1/6
Removable Lock-Down Door
When Activated, Locks Push
Button and Contacts in the
Powered Position.
Isolated Input and
Output Terminals
Separates Control
Circuits from Load Circuits.
F
l
ag In
d
icator
Shows Relay Status
in Manual or Powered
Condition.
Slim Design
Minimizes Space
on DIN Rail.
Finger-Safe
Protects Operators
from Live Circuits.
Color-Coded Push Button
Allows Manual Operation
of Relay. AC Coils Red or
DC Coils Blue.
2-Way Side or DIN
Rail Mounting System
Retrofits Existing Panel
Mounting and 35mm DIN Rail.
Mating Hold-Down
Clip Available
Safely Secures
Relay to Socket.
Finger Grip Cover
Easy Removal of
Relay from Socket.
Contact Viewing Window
Shows Position of Contacts.
Bi-Polar LED Status Lamp
Shows Coil “ON” or “OFF” Status.
I.D. Tag/Write-On
Plastic Label
Used for Identification
of Relays in Multi-Relay
Circuits.
Module Compatible
Allows for Optional
Protection or LED Modules
to be Used With Sockets.
Internal Coil Bus Jumper System
Allows Connection to Adjacent
Sockets Without Additional Wiring.
I.D. Tag/Write-On
Plastic Label
Used to Match Wire
Identification Tags with
Socket Connections.
Gold Flashed Contacts
Prevents Premature Oxidation
and Increases Shelf-life.
www.magnecraft.com 847-441-2540
Magnecraft Solution Guide 105A
SECTION 1
Magnecraft Solution Guide 105A
1/7
The Complete
System
Solution!
Isolated Input and
Output Terminals
Separates Control
Circuits from Load Circuits.
Flag Indicator
Shows Relay Status
in Manual or Powered
Condition.
2-Way Side or DIN
Rail Mounting System
Retrofits Existing Panel
Mounting and 35mm DIN Rail.
Finger Grip Cover
Easy Removal of Relay
from Socket.
Contact Viewing Window
Shows Position of Contacts.
Optional Bi-Polar LED Status Lamp
Shows Coil “ON” or “OFF” Status.
I.D. Tag/Write-On
Plastic Label
Used for Identification
of Relays in Multi-Relay
Circuits.
Module Compatible
Allows for Optional
Protection or LED Modules
to be Used With Sockets.
I.D. Tag/Write-On
Plastic Label
Used to match wire
identification tags
with socket connections.
Mating Hold-Down
Clip Available
Secures Relay to Socket.
Gold Flashed Contacts
Prevents Premature Oxidation
and Increases Shelf-life.
www.magnecraft.com 847-441-2540
SECTION 1
Magnecraft Solution Guide 105A
Magnecraft Solution Guide 105A
Advantages of a Plain Cover, Octal 700 Series Relay
• Offers a “one stop solution” for
your power management
system.
• Several Contact congurations
and materials to meet your
individual needs.
• Plug-In switching capabilities
from 10 mA to 16 Amps.
• Several Feature Code and
Operation combinations avail-
able for all budgets.
• Ejector clips, ribbed relay hous-
ings
and space-saving sockets
allow for easy removal from
crowded DIN rails.
• Color and appearance designed
for high visibility in all environ-
ments.
• Wiring diagrams include NEMA
and IEC standards.
• Engineering availability allows
for customized relay solutions.
Plain Cover octal style relays provide a
historical interface for the budget minded
yet performance driven customer. The Plain
Cover 750 relays allow the customer to
utilize the performance of a premium relay
while adhering to an aggressive budget.
This is accomplished by Magnecrafts
ability to utilize the electrical components
of the Full Feature 750 relays and deleting
options that may not be required by the
customer. The 750 Plain Cover relays offer
competitive pricing while maintaining
premium performance.
1/8
Isolated Input and
Output Terminals
Separates Control
Circuits from Load Circuits.
Flag Indicator
Shows Relay Status
in Manual or Powered
Condition.
2-Way Side or DIN
Rail Mounting System
Retrofits Existing Panel
Mounting and 35mm DIN Rail.
Finger Grip Cover
Easy Removal of Relay
from Socket.
Contact Viewing Window
Shows Position of Contacts.
Optional Bi-Polar LED Status Lamp
Shows Coil “ON” or “OFF” Status.
I.D. Tag/Write-On
Plastic Label
Used for Identification
of Relays in Multi-Relay
Circuits.
Module Compatible
Allows for Optional
Protection or LED Modules
to be Used With Sockets.
I.D. Tag/Write-On
Plastic Label
Used to match wire
identification tags
with socket connections.
Mating Hold-Down
Clip Available
Secures Relay to Socket.
Gold Flashed Contacts
Prevents Premature Oxidation
and Increases Shelf-life.
www.magnecraft.com 847-441-2540
Magnecraft Solution Guide 105A
SECTION 1
Magnecraft Solution Guide 105A
1/9
The Complete
System
Solution!
2.1
(50.3)
2.2
(55.2)
0.24
(6.1) 1.4
(34.9)
1.4
(35.4) 1.4
(35.4)
1.4
(34.9)
22
A2
7
A12
8
11
131
24
6
14
3
5
12
422
2
A1
7
A2
1
11
8
31
14
3
24
6
12
45
IEC
NEMA
750XAX
~
~
~
~
~
~
~
~
~
General Specifications (UL 508)
SECTION 1
Magnecraft Solution Guide 105A
UL Recognized
File No. E43641
UL
US
C
UL Listed When Used
With Magnecraft
Sockets.
WHITE
Magnecraft Solution Guide 105A
750 Octal Relays, 8-Pin/SPDT, 16 Amp Rating (DC & AC)
1/24
Removable
Lock-Down Door
Flag indicator
Removable I.D. Tag
LED Status Lamp
Finger Grip Cover
Push-To-Test Button
Blowout Magnet available
for DC switching-Code 69
Units
A
V
Resistive
Resistive
Resistive
HP
HP
Pilot Duty
mA
V
V
VA
W
(Resistive)
ms
Vrms
Vrms
Vrms
°C
°C
g-n
g-n
grams
Standard
SPDT
Silver Alloy
16
300
16A @ 277V 50/60Hz
16A @ 120V 50/60Hz
16A @ 28V
1/3 @ 120VAC
1/2 @ 240 VAC
B300
100 @ 5VDC (.5W)
6....240
6....125
85% to 110%
80% to 110%
3
1.4
15%
10%
100,000
5,000,000
20
1500
1500
1500
UL, CSA,CE
-40...+85
-40...+55
3, 10 - 55 Hz
10
IP 40
89
% of Nominal
Operations @ Rated Current
Unpowered
Between coil and contact
Between poles
Between contacts
Standard version
Storage
Operation
Operational
Contact Characteristics
Number and type of Contacts
Contact materials
Thermal (Carrying) Current
Maximum Switching Voltage
Switching Current @ Voltage
Minimum Switching Requirement
Coil Characteristics
Voltage Range
Operating Range
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical Life (UL508)
Mechanical Life
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Vibration resistance
Shock resistance
Degree of protection
Weight
Wiring Diagram
Bottom View
Full Featured Dimensions Plain Cover Dimensions
750XAX
Contact Viewing
Window
Gold Flashed Contacts
A2 A1
INPUT
72
14
3
12
4
22
24
5
21
8
6
11
1
A2
22
24
12
14
11
21
Coil Jumper Buss
A1
8
7
6
54
3
2
1
MODULE
INPUT
72
1
8
4
5
3
6
(96)
(75)
(36)
(40)
(92)
(96)
(30)
(7)
(45)
3.77
0.24
2.95
3.62
3.77
1.77 1.41
1.18
1.60
0.27
(6.1)
INPUT
4.13
(105)
0.74
(19)
NEMA:
IEC:
IEC
NEMA
Full Featured Plain Cover
Custom Relay Part Number Builder
Standard Part Numbers
Magnecraft Solution Guide 105A
SECTION 1
www.magnecraft.com 847-441-2540
Magnecraft Solution Guide 105A
750
Series
750
XAX
Contact Conguration
XAX = SPDT
Contact Code
16 Amp Silver Alloy = No Code
C
Cover Options
Full Feature = No Code
Plain Cover = C
ML-
Feature Options
Side Push Button = M
Locking Push Button = M4
Bi-Polar LED = L
240A
Coil Voltage
VAC = 6 - 240A
VDC = 6 - 125D
Coil Resistance
4.2 Ohms
18 Ohms
72 Ohms
1700 Ohms
7200 Ohms
32 Ohms
120 Ohms
470 Ohms
1800 Ohms
10000 Ohms
SPDT Part Number
(Full Feature)
16 Amp
750XAXM4L-6A
750XAXM4L-12A
750XAXM4L-24A
750XAXM4L-120A
750XAXM4L-220/240A
750XAXM4L-6D
750XAXM4L-12D
750XAXM4L-24D
750XAXM4L-48D
750XAXM4L-110/125D
SPDT Part Number
(Plain Cover) 16 Amp
750XAXC-6A
750XAXC-12A
750XAXC-24A
750XAXC-120A
750XAXC-220/240A
750XAXC-6D
750XAXC-12D
750XAXC-24D
750XAXC-48D
750XAXC-110/125D
Nominal Voltage
AC Operated
6 VAC 50/60 Hz
12 VAC 50/60 Hz
24 VAC 50/60 Hz
120 VAC 50/60 Hz
220-240 VAC 50/60 Hz
DC Operated
6 VDC
12 VDC
24 VDC
48 VDC
110-125 VDC
1/25
70-750EL8-1
SOCKET
For other mating sockets, see Section 2: 70-750E8-1, 70-750DL8-1, 70-464-1, 70-169-1
16-1351
Metal Hold-Down Clip
Section 3, p.8-11
2.1
(50.3)
2.2
(55.2)
0.24
(6.1) 1.4
(34.9)
1.4
(35.4)
2
A1
1
11
14
3
12
4
7
A2
8
31
24
14
6
22
5
11
A1
12 22
24
A2
31
1
2
3
45
6
7
8
1.4
(35.4)
1.4
(34.9)
IEC
NEMA
2.1
(50.3)
2.2
(55.2)
0.24
(6.1) 1.4
(34.9)
1.4
(35.4)
2
A1
1
11
14
3
12
4
7
A2
8
31
24
14
6
22
5
11
A1
12 22
24
A2
31
1
2
3
45
6
7
8
1.4
(35.4)
1.4
(34.9)
IEC
NEMA
750XBXGeneral Specifications (UL 508)
~
~
~
~
~
~
~
~
~
SECTION 1
Magnecraft Solution Guide 105A
UL Recognized
File No. E43641
UL
US
C
UL Listed When Used
With Magnecraft
Sockets.
WHITE
Magnecraft Solution Guide 105A
750 Octal Relays, 8-Pin/DPDT, 16 Amp Rating (DC & AC)
1/26
Removable
Lock-Down Door
Flag indicator
LED Status Lamp
Finger Grip Cover
Push-To-Test Button
Blowout Magnet available
for DC switching-Code 69
Units
A
V
Resistive
Resistive
Resistive
HP
HP
Pilot Duty
A
mA
V
V
VA
W
(Resistive)
ms
Vrms
Vrms
Vrms
°C
°C
g-n
g-n
grams
Standard
DPDT
Silver Alloy
16
300
16A @ 277V 50/60Hz
16A @ 120V 50/60Hz
16A @ 28V
1/3 @ 120VAC
1/2 @ 240 VAC
B300
3 @ 150VDC
100 @ 5VDC (.5W)
6....240
6....125
85% to 110%
80% to 110%
3
1.4
15%
10%
100,000
5,000,000
20
1500
1500
1500
UL, CSA, CE
-40...+85
-40...+55
3, 10 - 55 Hz
10
IP 40
89
% of Nominal
Operations @ Rated Current
Unpowered
Between coil and contact
Between poles
Between contacts
Standard version
Storage
Operation
Operational
Contact Characteristics
Number and type of Contacts
Contact materials
Thermal (Carrying) Current
Maximum Switching Voltage
Switching Current @ Voltage
Current rating with magnetic
blowout - Code 69
Minimum Switching Requirement
Coil Characteristics
Voltage Range
Operating Range
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical Life (UL508)
Mechanical Life
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Vibration resistance
Shock resistance
Degree of protection
Weight
Wiring Diagram
Bottom View
Full Featured Dimensions Plain Cover Dimensions
750XBX
Removable I.D. Tag
Contact Viewing
Window
Gold Flashed Contacts
Full Featured Plain Cover
A2 A1
INPUT
72
14
3
12
4
22
24
5
21
8
6
11
1
A2
22
24
12
14
11
21
Coil Jumper Buss
A1
8
7
6
54
3
2
1
MODULE
INPUT
72
1
8
4
5
3
6
(96)
(75)
(36)
(40)
(92)
(96)
(30)
(7)
(45)
3.77
0.24
2.95
3.62
3.77
1.77 1.41
1.18
1.60
0.27
(6.1)
INPUT
4.13
(105)
0.74
(19)
NEMA:
IEC:
IEC
NEMA
Custom Relay Part Number Builder
Standard Part Numbers BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
Magnecraft Solution Guide 105A
SECTION 1
www.magnecraft.com 847-441-2540
Magnecraft Solution Guide 105A
750
Series
750
XBX
Contact Conf.
XBX = DPDT
Contact Code
16 Amp Silver Alloy = No Code
C
Cover Options
Full Feature = No Code
Plain Cover = C
ML-
Feature Options
Side Push Button = M
Locking Push Button = M4
Bi-Polar LED = L
240A
Coil Voltage
VAC = 6 - 240A
VDC = 6 - 250D
Coil Resistance
4.2 Ohms
18 Ohms
72 Ohms
1700 Ohms
7200 Ohms
32 Ohms
120 Ohms
470 Ohms
1800 Ohms
10000 Ohms
DPDT Part Number
(Full Feature)
16 Amp
750XBXM4L-6A
750XBXM4L-12A
750XBXM4L-24A
750XBXM4L-120A
750XBXM4L-220/240A
750XBXM4L-6D
750XBXM4L-12D
750XBXM4L-24D
750XBXM4L-48D
750XBXM4L-110/125D
DPDT Part Number
(Plain Cover) 16 Amp
750XBXC-6A
750XBXC-12A
750XBXC-24A
750XBXC-120A
750XBXC-220/240A
750XBXC-6D
750XBXC-12D
750XBXC-24D
750XBXC-48D
750XBXC-110/125D
Nominal Voltage
AC Operated
6 VAC 50/60 Hz
12 VAC 50/60 Hz
24 VAC 50/60 Hz
120 VAC 50/60 Hz
220-240 VAC 50/60 Hz
DC Operated
6 VDC
12 VDC
24 VDC
48 VDC
110-125 VDC
DC Switching Option
Magnetic Blowout = 69
1/27
70-750EL8-1
SOCKET
For other mating sockets, see Section 2: 70-750E8-1, 70-750DL8-1, 70-464-1, 70-169-1
16-1351
Metal Hold-Down Clip
Section 3, p.8-11
750XCX
2.1
(50.3)
2.2
(55.2)
0.24
(6.1) 1.4
(34.9)
1.4
(35.4)
10
2
A1 A2
1
11
3
12
4
11
6
21 31
24 34
7
22
9
32
58
14
1
2
3
4
567
8
9
10
11
11
A1
14
12
22 21 24
32
34
A2
31
1.4
(35.4)
1.4
(34.9)
IEC
NEMA
2.1
(50.3)
2.2
(55.2)
0.24
(6.1) 1.4
(34.9)
1.4
(35.4)
10
2
A1 A2
1
11
3
12
4
11
6
21 31
24 34
7
22
9
32
58
14
1
2
3
4
567
8
9
10
11
11
A1
14
12
22 21 24
32
34
A2
31
1.4
(35.4)
1.4
(34.9)
IEC
NEMA
~
~
~
~
~
~
~
~
~
General Specifications (UL 508)
SECTION 1
Magnecraft Solution Guide 105A
UL Recognized
File No. E43641
UL
US
C
UL Listed When Used
With Magnecraft
Sockets.
WHITE
Magnecraft Solution Guide 105A
750 Octal Relays, 11-Pin/3PDT, 16 Amp Rating (DC & AC)
1/28
Flag indicator
LED Status Lamp
Removable
Lock-Down Door
Finger Grip Cover
Push-To-Test Button
Blowout Magnet available
for DC switching-Code 69
Units
A
V
Resistive
Resistive
Resistive
HP
HP
Pilot Duty
mA
V
V
VA
W
(Resistive)
ms
Vrms
Vrms
Vrms
°C
°C
g-n
g-n
grams
Standard
3PDT
Silver Alloy
16
300
16A @ 277V 50/60Hz
16A @ 120V 50/60Hz
16A @ 28V
1/3 @ 120VAC
1/2 @ 240 VAC
B300
100 @ 5VDC (.5W)
6....240
6....125
85% to 110%
80% to 110%
3
1.4
15%
10%
100,000
5,000,000
20
1500
1500
1500
UL, CSA, CE
-40...+85
-40...+55
3, 10 - 55 Hz
10
IP 40
89
% of Nominal
Operations @ Rated Current
Unpowered
Between coil and contact
Between poles
Between contacts
Standard version
Storage
Operation
Operational
Contact Characteristics
Number and type of Contacts
Contact materials
Thermal (Carrying) Current
Maximum Switching Voltage
Switching Current @ Voltage
Minimum Switching Requirement
Coil Characteristics
Voltage Range
Operating Range
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical Life (UL508)
Mechanical Life
Operating time (response time)
Dielectric strength
Environment
Product certifications
Ambient air temperature
around the device
Vibration resistance
Shock resistance
Degree of protection
Weight
Full Featured Dimensions Plain Cover Dimensions
750XCX
Wiring Diagram
Bottom View
Removable I.D. Tag
Contact Viewing
Window
Gold Flashed Contacts
A2 A1
72
INPUT
12
4
11
1
31
32
11
24
7
8
21
6
14
3
34
9
22
5
32
24
21
31
34
22 12
11
14
A2 A1
10
7
5
3
9
84
11 61
2
1
6
11
8
9
7
3
4
10
2
(96)
(75)
(36)
(40)
(92)
(96)
(30)
(7)
(63)
3.77
0.24
2.95
3.62
3.77
2.48 1.4
1.18
1.60
0.27
(6.1)
5
(105)
4.13
0.74
(19)
Coil Jumper Buss
MODULE
INPUT
INPUT
IEC
NEMA
NEMA:
IEC:
Full Featured Plain Cover
Custom Relay Part Number Builder
Standard Part Numbers BOLD-FACED PART NUMBERS ARE NORMALLY STOCKED
Magnecraft Solution Guide 105A
SECTION 1
www.magnecraft.com 847-441-2540
Magnecraft Solution Guide 105A
Coil Resistance
4.2 Ohms
18 Ohms
72 Ohms
1700 Ohms
7200 Ohms
32 Ohms
120 Ohms
470 Ohms
1800 Ohms
10000 Ohms
3PDT Part Number
(Full Feature)
16 Amp
750XCXM4L-6A
750XCXM4L-12A
750XCXM4L-24A
750XCXM4L-120A
750XCXM4L-220/240A
750XCXM4L-6D
750XCXM4L-12D
750XCXM4L-24D
750XCXM4L-48D
750XCXM4L-110/125D
3PDT Part Number
(Plain Cover) 16 Amp
750XCXC-6A
750XCXC-12A
750XCXC-24A
750XCXC-120A
750XCXC-220/240A
750XCXC-6D
750XCXC-12D
750XCXC-24D
750XCXC-48D
750XCXC-110/125D
Nominal Voltage
AC Operated
6 VAC 50/60 Hz
12 VAC 50/60 Hz
24 VAC 50/60 Hz
120 VAC 50/60 Hz
220-240 VAC 50/60 Hz
DC Operated
6 VDC
12 VDC
24 VDC
48 VDC
110-125 VDC
750
Series
750
XCX
Contact Conguration
XCX = 3PDT
Contact Code
16 Amp Silver Alloy = No Code
C
Cover Options
Full Feature = No Code
Plain Cover = C
ML-
Feature Options
Side Push Button = M
Locking Push Button = M4
Bi-Polar LED = L
240A
Coil Voltage
VAC = 6 - 240A
VDC = 6 - 125D
1/29
70-750EL11-1
SOCKET
For other mating sockets, see Section 2: 70-750E11-1, 70-750DL11-1, 70-465-1, 70-170-1
16-1351
Metal Hold-Down Clip
Section 3, p.8-11
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schneider Electric:
750XCXC-12D 750XBXC-120A 750XBXC-220/240A 750XBXM4L-220/240A 750XBXCL-220/240A 750XCXM4L-
220/240A 750XBXC-110D 750XBXCL-120A 750XCXC-110D 750XCXC-24D 750XCXC-24A 750XCXC-240A
750XBXC-12D 750XBXC-24A 750XBXC-24D 750XCXC-120A 750XCXC-6A 750XCXM4L-120A 750XCXM4L-24D