CP 5613 A3/CP 5614 A3
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SIMATIC NET
PG/PC - PROFIBUS
CP 5613 A3/CP 5614 A3
Operating Instructions
08/2016
C79000
-G8976-C277-02
Preface
Description of the device
1
Software installation
2
Hardware installation
3
Configuration
4
Technical specifications
5
Approvals
A
Document order number: C79000-G8976-C277
09/2016 Subject to change
Copyright © Siemens AG 2016.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 3
Preface
What the consignment contains
The following components are supplied with the CP 5613 A3 / CP 5614 A3:
Communications processor CP 5613 A3 or communications processor CP 5614 A3
SIMATIC NET DVD including
"SIMATIC NET PC Software"
Manual Collection
Certificate of license
Please check that the consignment you have received is complete. If it is not complete,
please contact your supplier or your local Siemens office.
Validity of this documentation
These operating instructions are valid for the following products:
CP 5613 A3
Article number: 6GK1 561-3AA02
CP 5614 A3
Article number: 6GK1 561-4AA02
Content of this documentation
These operating instructions contain information about the installation and configuration of
the 5613 A3 and CP 5614 A3 communications processors.
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support pages
under the following entry ID:
77377283 (https://support.industry.siemens.com/cs/ww/en/view/77377283)
Further documentation
The documents listed below contain more detailed information on commissioning and using
the communications processor. You will find this documentation on the Product Support
pages on the Internet under the following entry link:
Support (https://support.industry.siemens.com/cs/ww/en/ps)
Preface
CP 5613 A3/CP 5614 A3
4 Operating Instructions, 08/2016, C79000-G8976-C277-02
Enter the entry ID shown below of the relevant manual as the search item.
Configuration manual Commissioning PC Stations
This provides you with detailed information on commissioning and configuring SIMATIC
NET PC communications modules.
Entry ID:
109488960 (https://support.industry.siemens.com/cs/ww/en/view/109488960)
System manual SIMATIC NET Industrial Communication with PG/PC
Volume 1Basics
Entry ID:
77376110 (https://support.industry.siemens.com/cs/ww/en/view/77376110)
Volume 2Interfaces
Entry ID:
77378184 (https://support.industry.siemens.com/cs/ww/en/view/77378184)
The system manuals introduce the topic of industrial communication and explain the
communications protocols used. There is also a description of the OPC interface as
user programming interface.
Installation manual "SIMATIC NET PC Software"
This document contains detailed information on installing the "SIMATIC NET
PC Software".
Entry ID:
109459606 (https://support.industry.siemens.com/cs/ww/en/view/77377602)
System manual PROFIBUS Network Manual
In this document you will find detailed information about setting up a PROFIBUS network.
Entry ID:
35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591)
SIMATIC NET documentation
You will find the entire SIMATIC NET documentation on the pages of Product Support:
15247 (https://support.industry.siemens.com/cs/ww/en/ps/15247)
Go to the required product group and make the following settings:
Entry list Entry type "Manuals / Operating Instructions"
Trademarks
The following and possibly other names not identified by the registered trademark sign ® are
registered trademarks of Siemens AG:
SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614,
CP 5622
Preface
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 5
Industry Online Support
In addition to the product documentation, the comprehensive online information platform of
Siemens Industry Online Support at the following Internet address:
(http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang=
en)
Apart from news, there you will also find:
Project information: Manuals, FAQs, downloads, application examples etc.
Contacts, Technical Forum
The option submitting a support query:
(https://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid
=38718979&caller=view)
Our service offer:
Right across our products and systems, we provide numerous services that support you
in every phase of the life of your machine or system - from planning and implementation
to commissioning, through to maintenance and modernization.
You will find contact data on the Internet at the following address:
(http://www.automation.siemens.com/partner/guiwelcome.asp?lang=en)
SITRAIN - Training for Industry
The training offer includes more than 300 courses on basic topics, extended knowledge and
special knowledge as well as advanced training for individual sectors - available at more
than 130 locations. Courses can also be organized individually and held locally at your
location.
You will find detailed information on the training curriculum and how to contact our customer
consultants at the following Internet address:
(www.siemens.com/sitrain)
SIMATIC NET glossary
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary on the Internet at the following address:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045)
Preface
CP 5613 A3/CP 5614 A3
6 Operating Instructions, 08/2016, C79000-G8976-C277-02
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 7
Table of contents
Preface ................................................................................................................................................... 3
1 Description of the device ......................................................................................................................... 9
1.1 Properties of the CP 5613 A3 ................................................................................................... 9
1.2 Properties of the CP 5614 A3 ................................................................................................. 10
1.3 PROFIBUS interface ............................................................................................................... 11
1.4 Meaning of the LED display .................................................................................................... 13
2 Software installation .............................................................................................................................. 15
2.1 Installing the "SIMATIC NET PC Software" ............................................................................ 15
2.2 Uninstalling the "SIMATIC NET PC Software"........................................................................ 16
3 Hardware installation ............................................................................................................................. 17
3.1 Safety notices ......................................................................................................................... 17
3.2 Installing hardware .................................................................................................................. 18
3.3 Hardware compatibility............................................................................................................ 19
4 Configuration ........................................................................................................................................ 21
5 Technical specifications ........................................................................................................................ 23
A Approvals .............................................................................................................................................. 25
Table of contents
CP 5613 A3/CP 5614 A3
8 Operating Instructions, 08/2016, C79000-G8976-C277-02
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 9
Description of the device
1
1.1
Properties of the CP 5613 A3
Properties
The CP 5613 A3 is a communications processor for connecting PCs (personal computers) or
PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are
as follows:
Transmission speeds up to 12 Mbps.
Floating RS-485 connector.
Linking of up to 32 devices (PC, PG, SIMATIC S7 or ET 200) to form a network segment.
By linking several segments with repeaters, up to 124 nodes can be connected.
The additional interface signals for a direct link to a PLC (Programmable Logic Controller)
are supported up to 187.5 Kbps.
Installation in PGs and PCs with a PCI slot. The following is supported:
PCI, 33 MHz / 66 MHz, 32 bits / 64 bits
Plug and play
Optimized for fast DP master operation (DP Base) with up to 124 DP slaves with full data
consistency.
Relief of the PC/PG with event mechanisms.
Automatic detection of data changes.
Fast logic support regardless of the user program.
Automatic linking of input and output data can be set by the user program.
Measurement of own operating temperature with temperature sensor.
Display of the total operating hours with operating hours counter.
Description of the device
1.2 Properties of the CP 5614 A3
CP 5613 A3/CP 5614 A3
10 Operating Instructions, 08/2016, C79000-G8976-C277-02
Appearance
The following graphic shows the CP 5613 A3 communications processor:
1
LEDs
2
PROFIBUS interface PB1 (master or slave)
1.2
Properties of the CP 5614 A3
Properties
The CP 5614 A3 is a communications processor for connecting PCs (personal computers) or
PGs (programming devices) to PROFIBUS and MPI networks. In addition to the properties of
the CP 5613 A3, the CP 5614 A3 also has the following features:
Additional PROFIBUS connection as DP slave to a second DP network.
DP master and DP slave can be operated at the same time.
Program-controlled data transfer between master and slave module for setting up
hierarchical PROFIBUS networks.
Description of the device
1.3 PROFIBUS interface
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 11
Appearance
The following graphic shows the CP 5614 A3 communications processor:
1
LEDs
2
PROFIBUS interface PB1 (master only)
3
PROFIBUS interface PB2 (slave only)
1.3
PROFIBUS interface
Note
Connector with 180° cable outlet
Use the bus connector with a 180°
cable outlet if you want to use the lower PROFIBUS
connector (PB2, slave only) or both PROFIBUS connectors at the same time. You can obtain
these connectors, for example, under the following order numbers:
6GK1 500-0FC10
6GK1 500-0EA02
Description of the device
1.3 PROFIBUS interface
CP 5613 A3/CP 5614 A3
12 Operating Instructions, 08/2016, C79000-G8976-C277-02
PROFIBUS network
The physical link between the PROFIBUS interface and the PROFIBUS network is via a
floating RS-485 interface that is part of the module. Depending on the network configuration,
data rates of 9.6 Kbps up to a maximum of 12 Mbps are possible in the PROFIBUS network.
Note
You will find information about the structure of a PROFIBUS network in the system manual
"PROFIBUS Network Manual". The document is part of the Manual Collection. You will also
find this on the Product Support pages under the following entry ID:
35222591 (
https://support.industry.siemens.com/cs/ww/en/view/35222591)
PIN assignment
The D-sub female connector has the following pin assignment:
PIN
Short name
Meaning
Input/output
1
NC
Socket pin 1 is not connected.
-
2 NC (M24) Socket pin 2 is not connected. With other MPI/DP components,
the return line of the floating 24 V power supply may be via this
pin.
-
3
LTG_B
Signal line B of the PROFIBUS connector.
Input/output
4 RTSAS RTSAS, input signal for direct MPI link. The control signal is "1"
active when the automation system connected over a special
MPI cable is sending.
Input
5 M5EXT M5EXT return line (GND) of the 5 V power supply. The current
load of an external consumer connected between P5EXT and
M5EXT must not exceed a maximum of 90 mA.
Output
6 P5EXT P5EXT supply (+5 V) of the 5 V power supply. The current load
of an external consumer connected between P5EXT and
M5EXT must not exceed a maximum of 90 mA (short-circuit
proof).
Output
7 NC (P24V) Socket pin 7 is not connected. With other MPI/DP components,
the P24V supply of the floating 24 V power supply may be via
this pin.
-
8
LTG_A
Signal line A of the PROFIBUS connector.
Input/output
9 RTS RTS output signal of the CP module. The control signal is "1"
active when the device (PG or PC) is sending.
Output
Shield The shield is connected to components of the connector hous-
ing.
Description of the device
1.4 Meaning of the LED display
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 13
1.4
Meaning of the LED display
LED display
The meaning of the LED display is as follows:
Green and yellow LED
Meaning
Green on
Indicates token rotation (in other words, normal operation)
Green off Incorrect bus parameters, defective bus or CP not in operation
Green flashing at one-second inter-
vals
Bad database
Green flashing fast, yellow off Module not started; normal status following reset
Green and yellow flashing alternately When using more than one module in a PG/PC:
Identification of the module by a diagnostics tool
Green and yellow flashing synchro-
nously
Exception state; error in firmware
One of the two LEDs is on, the sec-
ond is flashing quickly
Error initializing the module
Applies only to
DP slave operation
with the CP 5614 A3
Yellow on
Indicates polling by the higher-level DP master
Yellow off DP slave connection is not addressed.
Description of the device
1.4 Meaning of the LED display
CP 5613 A3/CP 5614 A3
14 Operating Instructions, 08/2016, C79000-G8976-C277-02
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 15
Software installation
2
2.1
Installing the "SIMATIC NET PC Software"
SIMATIC NET PC software
You require the SIMATIC NET PC software to operate the communications processor in your
PG/PC.
To configure the CP, you require additional configuration software. You will find information
on the configuration software in the section Configuration (Page 21).
Condition
The plug and play function is activated in the BIOS of your computer.
Prior to hardware installation
Install the software as described in the installation manual "SIMATIC NET PC Software".
You will find this installation manual on the Product Support pages under the following entry
ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602)
You should also note the current information on the "SIMATIC NET PC Software" on the
Product Support pages under entry ID:
15362 (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm)
After the hardware installation
After installing the CP, your PG/PC automatically searches for a suitable driver.
1. Follow the instructions of the Hardware Wizard of Windows.
2. Do
not
activate the search for drivers on the Internet.
Software installation
2.2 Uninstalling the "SIMATIC NET PC Software"
CP 5613 A3/CP 5614 A3
16 Operating Instructions, 08/2016, C79000-G8976-C277-02
2.2
Uninstalling the "SIMATIC NET PC Software"
Condition
The "SIMATIC NET PC Software" is installed on the PG/PC.
Procedure
Note
The recommended procedure removes the entire "SIMATIC NET PC Software" on the
PG/PC, not only the driver f
or the communications processor.
Uninstall the entire software package as described and recommended in the installation
manual "SIMATIC NET PC Software".
You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the
Product Support pages under the following entry ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602)
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 17
Hardware installation
3
3.1
Safety notices
WARNING
Electric shock possible - work only when the power supply is off
Opening the PG/PC and plugging or pulling the communications processor is permitted
only when the power is off.
Turn off your PG/PC and pull the power cable connector before you start the hardware
installation.
NOTICE
Note the EC directives
Components can be damaged or destroyed by electrostatic discharge. When installing,
keep to the rules for electrostatically sensitive devices (ESD).
Pick up components and modules only by their edges. Do not touch the pins or
conductors.
Before opening the PG/PC, make sure that you discharge any electrostatic charge from
your body. You can do this by touching metal parts on the back panel of the PG/PC
pulling the power plug.
Make sure that you also discharge any electrostatic charge from tools you intend to use
for the work on the PG/PC.
Do not operate the PG/PC with the housing open.
NOTICE
Firm mounting
The communications processor must sit firmly and uniformly in the slot. Check that the
module sits firmly in the slot as described in the manual accompanying your PG/PC.
Note
Oblique installation position is permitted
Some PG/PC designs require oblique installation of the communications processor. This is
permitted.
Hardware installation
3.2 Installing hardware
CP 5613 A3/CP 5614 A3
18 Operating Instructions, 08/2016, C79000-G8976-C277-02
3.2
Installing hardware
Permitted number of communications processors in the PG/PC
The driver software supports a maximum of 4 communications processors per PG/PC.
Automatic adaptation of the bus clock speed
The communications processor is designed for a bus clock speed of 66 MHz. If the
communications processor is inserted in a PCI slot with a higher bus clock speed, the bus
clock speed is adapted to the highest possible bus rate of the communications processor.
Examples:
The PCI slot is automatically reduced to a bus clock speed of 66 MHz.
The bus clock speed of the communications processor is automatically reduced to 33
MHz if a communications processor with a 33 MHz bus clock speed is connected.
Procedure
Note
First install the software
First install the software before you insert the communications processor in the slot.
Activated plug and play function
The plug and play function must be activated in the BIOS of your PG/PC.
Follow the steps outlined below when inserting the communications processor:
1. Turn off your PG/PC and pull the power cable connector.
2. Open the PC housing as described in the manual accompanying your PG/PC.
3. Remove the cover of a free PCI slot.
4. Remove the communications processor from its packaging.
5. Insert the communications processor in the PCI slot and secure it.
Make sure that the communications processor is correctly inserted and secured.
6. Close the PC housing as described in the manual accompanying your PG/PC.
7. Insert the power plug into the socket again and turn your PG/PC on.
The plug and play function of Windows automatically searches for a driver.
8. Follow the instructions of the Hardware Wizard of Windows.
Do not
activate the search for drivers on the Internet.
Hardware installation
3.3 Hardware compatibility
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 19
3.3
Hardware compatibility
Compatibility with predecessor versions
The CP 5613 A3 can replace the following predecessor versions:
CP 5613 A2
CP 5613
The CP 5614 A3 can replace the following predecessor versions:
CP 5613 A2 and CP 5614 A2
CP 5613 and CP 5614
Note
No configuration changes necessary
You can adopt
the configuration of the previous CP. To do this, you simply need to reload
the configuration.
Procedure for replacement
When replacing a module, follow the steps described in the section "Hardware installation
(Page 17)".
Hardware installation
3.3 Hardware compatibility
CP 5613 A3/CP 5614 A3
20 Operating Instructions, 08/2016, C79000-G8976-C277-02
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 21
Configuration
4
Configuring
To be able to configure the communications processor, the following engineering or
configuration tools are available:
STEP 7 V5.5
STEP 7 Professional (TIA Portal)
Communication Settings (COML S7)
The steps involved are described in the "Commissioning PC Stations" manual or in the
relevant online helps.
Compatibility during configuration
If there is not yet a CP 5613 A3 / CP 5614 A3 available in the hardware catalog of your
STEP 7 version, you can also select one of the following CPs for configuration:
CP 5613 A2 / CP 5614 A2
CP 5613/CP 5614
The CP 5613 A3 / CP 5614 A3 is downwards compatible with the configurations of the
previous versions.
NOTICE
Configurations not compatible
The DP slave configuration of a CP of the 5613 series is not compatible with the DP slave
configuration of a CP from the 5614 series. This means, for example, that the DP slave
configuration of a CP 5613 A3 cannot be loaded onto a CP 5614 A3 - or vice versa -
because the slave will not work with this configuration.
Configuration
CP 5613 A3/CP 5614 A3
22 Operating Instructions, 08/2016, C79000-G8976-C277-02
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 23
Technical specifications
5
CP 5613 A3/CP 5614 A3 technical specifications
Connection to PROFIBUS
Amount
For CP 5613 A3
For CP 5614 A3
1
2
Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps,
93.75 kbps, 187.5 kbps, 500 kbps,
1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps
Design 9-pin D-sub female connector with screw
locking mechanism
RS-485 (ungrounded within the SELV lim-
its)
Properties Grounded cable shield
Floating interface signals
Connection to PG/PC
PCI, 33 MHz / 66 MHz, 32 bit
signal voltage: 5 VDC or 3.3 VDC
V 2.2 plug and play
Electrical specifications of the PCI plug-in connector
Operating voltage
Rated voltage
3.3 VDC and 12 VDC
Permitted range 3.0 to 3.6 V DC
11.0 to 13.0 V DC
Properties Safety extra low voltage (SELV) to EN
60950
Current consumption Typical
For CP 5613 A3
For CP 5614 A3
150 mA at 3.3 V and 250 mA at 12 V
180 mA at 3.3V and 280 mA at 12 V
Effective power loss Typical
For CP 5613 A3
For CP 5614 A3
3.5
3.9 W
Permitted ambient conditions
Operating conditions Temperature
(EN 60068-2-1+2)
Maximum temperature change
+5 to +50°C
10 K/h
Rel. humidity
(EN 60068-2-78)
85% at 30 °C, no condensation
Rapid temperature change
(EN 60068-2-14)
+5 +50 °C, 5 cycles
Technical specifications
CP 5613 A3/CP 5614 A3
24 Operating Instructions, 08/2016, C79000-G8976-C277-02
CP 5613 A3/CP 5614 A3 technical specifications
Storage and transportation conditions Temperature
(EN 60068-2-1+2)
Maximum temperature change
-20 to +60 °C
20 K/h
Rel. humidity
(EN 60068-2-78)
95% at +25 °C to +55°C, no condensa-
tion
Fast temperature change
According to EN 60068-2-14
to EN 60068-2-30
-20 to +60 , 2 cycles
+25 to +55°C at 95% humidity
Vibration, operating
(EN 60068-2-6)
Frequency 10 to 58 Hz
Frequency 58 to 500 Hz
Number of cycles
0.075 mm amplitude
10 m/s2 Acceleration
10/axis
Shock, operating
(EN 60068-2-27)
Half sine
Time
Number of shocks
50 m/s2 (5 g)
30 ms
100/axis
Design, dimensions and weight
Module format
Flat module
Short PCI card
Weight For CP 5613 A3
For CP 5614 A3
98 g
113 g
Dimensions (W x H x D) in mm For CP 5613 A3
For CP 5614 A3
18 x 107 x 125
18 x 107 x 125
Electromagnetic compatibility
Emission According to EN 55022
to FCC
Class B
Class B
Immunity On signal cables
Surge to EN 610004-5
Burst to EN 61000-4-3
±2 kV
±2 kV
to discharge of static electricity
Contact discharge to IEC 61000-
4-2
±6 kV
to radiated radio frequencies
According to EN 61000-4-3
10 V/m at 80 MHz to 2 GHz
10 V/m, 50% on-load factor at 900 MHz
and 1.89 GHz
According to EN 61000-4-6 10 V/m, 80% amplitude modulation at
1 kHz, 10 kHz to 80 MHz
CP 5613 A3/CP 5614 A3
Operating Instructions, 08/2016, C79000-G8976-C277-02 25
Approvals
A
Note
The specified approvals apply only when the corresponding mark is printed on the
communications processor.
Electromagnetic compatibility - EMC directive
The communications processor meets the requirements of the EC Directive:2004/108/EEC
(EMC directive).
The communications processor is designed for use in the following areas:
Area of application
Requirements
Emission
Immunity
Residential areas, business and commercial opera-
tions, and small businesses
EN 61000-6-3 EN 61000-6-1
Industrial environment
EN 61000-6-4
EN 61000-6-2
Declaration of conformity
You will find the declaration of conformity for this communications processor on the Product
Support pages under the following entry ID:
58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997)
C-TICK approval
The communications processor meets the requirements of the Australian AS/NZS 3548
standard according to EN 61000-6-3.
ICES conformity
The communications processor meets the requirements of the Canadian standard ICES-003.
It is rated as a digital device of Class B ("Class B digital apparatus").
cULus Approval for Information Technology Equipment
cULus Listed I. T. E.
Underwriters Laboratories Inc. complying with
UL 60950-1 (Information Technology Equipment)
CSA C22.2 No. 60950-1-03
Approvals
CP 5613 A3/CP 5614 A3
26 Operating Instructions, 08/2016, C79000-G8976-C277-02
Report no. E115352
FCC approval
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Siemens AG is not responsible for any radio television interference caused by unauthorized
modifications of this equipment or the substitution or attachment of connecting cables and
equipment other than those specified by Siemens AG. The correction of interference caused
by such unauthorized modification, substitution or attachment will be the responsibility of the
user. The use of shielded I/O cables is required when connecting this equipment to any and
all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)