DATA SHEET
Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com
Part Number: MS22 20005
Ordering Different Lead Types:
For example: to order an inside kinked lead use part number MS22 20005-A
Electrical Specifications: Mechanical Specifications:
Revision Date: March 19, 2003
Inside Kinked Leads Use -A after Ametherm’s part #
Outside Kinked Leads Use -B after Ametherm’s part #
Resistance @ 25°C 20.0 Ω ± 25%
Max Steady State Current Up to 65°C 5.0 A
Max Recommended Energy Rating (Joules) 180.0 J
Actual Failure Point of Instantaneous Energy (Joules) 360.0 J
Resistance @ 100% of Max Current 0.190 Ω
Resistance @ 50% of Max Current 0.485 Ω
Body Temperature @ 100% Current Rating 170 °C
Dissipation Constant 42.5mW/°C
Thermal Time Co nstant 114 seconds
Material Type “H”
Max Recommended Capacitance
@120VAC/240VAC/440VAC 12000µF/
3000µF/ 900µF
Max Recommended Voltage 600 Vrms with
420µF
D 20.0 ± 1.0 mm
T 5.0 ± 0.2 mm
Lead Diameter 1.0 ± 0.1 mm
S 7.8 ± 2.0 mm
L 38.0 ± 9.0 mm
Straight Leads
Coati ng Run Down 5.0 ± 1.0 mm
B 9.35 ± 0.85 mm
C 3.82 ± 1.0 mm
L
OUTSIDE
KINKED LEADS
S
STRAIGHT
LEADS
B
INSIDE
KINKED LEADS
S S
D D D
C
T