Evacuated Miniature Crystal Oscillator
The EX-400 provides exceptionally low aging rates and tight temperature stabilities in an extremely small package over a wide
range of environmental conditions. This EMXO series bridges the gap between current large, high precision OCXOs and smaller
TCXO’s. The EX-400 Series becomes the most economical choice where there is a need for spectral purity, short and long term
stability, along with small size and dramatically reduced power consumption.
4-Pin Dip
Uses Doubly Rotated Crystal
Low Power Consumption: <0.35 watts @ +25°C
Previous Model Number: EX-380, EX-381, EX-385 series
Frequency Range: 10 MHz - 80 MHz
SONET/SDH, DWDM, FDM, ATM, 3G
Telecom Transmission and Switching Equipment
Wireless Communication Equipment
Military Airborne and Mobile systems
Features Applications
Description
Performance Specications
Frequency Stabilities1
Parameter Min Typical Max Units Condition
vs. operating temperature range (reference to
+25°C)
-75
-100
-250
+75
+100
+250
ppb
-20... +70°C (10 to 20.49 MHz)
-20... +70°C (10 to 50 MHz)
-20... +70°C (10 to 80 MHz)
-100
-150
-250
+100
+150
+250
ppb
-40… +85°C (10 to 20.49 MHz)
-40… +85°C (10 to 50 MHz)
-40… +85°C (10 to 80 MHz)
-150
-250
+150
+250 ppb -55… +85°C (10 to 50 MHz)
-55… +85°C (10 to 80 MHz)
vs. Stratum3 per
GR-1244-
CORE
Operating Temp -140
-140
-140
+140
+140
+140
ppb
-20… +70°C
-40… +85°C (10 to 50 MHz)
-55… +85°C (10 to 20.49 MHz)
Holdover
Drift
MTIE
-370
-4.63
+370
+4.63
+1000
ppb
10-13/sec
ns
24 hours
Over 7100 seconds
0.16sec < Observe Times < 64 sec
Warm-up Time 1
2minutes to ± 1ppm of nal frequency (1 hour)
to ± 100ppb of nal frequency (1 hour)
Initial Tolerance (10 to 19.9 MHz)
Initial Tolerance (20 to 80 MHz)
-1.0
-1.5
+1.0
+1.5 ppm for xed frequency
vs. supply voltage change (10 to 50 MHz)
vs. supply voltage change (50 to 80 MHz)
-15
-25
+15
+25 ppb VS ± 5%
vs. load change (10 to 80 MHz) -15 +15 ppb Load ± 5%
EX-400
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
2 of 5
Performance Specications
Frequency Stabilities1 (continued)
Parameter Min Typical Max Units Condition
vs. aging / day (10 to 14.9 MHz)
vs. aging / day (15 to 19.9 MHz)
vs. aging / day (20 to 49.9 MHz)
vs. aging / day (50 to 80.0 MHz)
-1.0
-2.0
-3.0
-4.0
+1.0
+2.0
+3.0
+4.0
ppb after 30 days of operation
vs. aging / 1st year (10 to 14.9 MHz)
vs. aging / 1st year (15 to 19.9 MHz)
vs. aging / 1st year (20 to 80 MHz)
-200
-300
-500
+200
+300
+500
ppb after 30 days of operation
vs. aging / 10 year (10 to 14.9 MHz)
vs. aging / 10 year (15 to 19.9 MHz)
vs. aging / 10 year (20 to 80 MHz)
-1000
-2000
-3000
+1000
+2000
+3000
ppb after 30 days of operation
Supply Voltage (Vs)
Supply voltage (Vs) 4.75 5.0 5.25 VDC
Supply voltage (Vs) 3.135 3.3 3.465 VDC
Power Consumption
1.5
Watts
during warm-up
0.35 steady state @ +25°C (10 to 29.99 MHz)
0.45 steady state @ +25°C (30 to 80 MHz)
0.7 steady state @ -40°C (10 to 29.99 MHz)
0.8 steady state @ -40°C (30 to 80 MHz)
RF Output
Signal [Standard] HCMOS
Load 15 pF
Signal Level (Vol) 0.4 VDC
Signal Level (Voh) 4.0
2.6 VDC Vs=5 Vdc
Vs=3.3 vdc
Rise/Fall Time +5 ns (10-80%) of Vs
Duty cycle 40 60 % (Voh-Vol)/2
Signal [Option] Sinewave
Load 50 ohm
Output Power [Standard] 0 +4 dBm 50 ohm load
Output Power [Option} +3 +7 dBm 50 ohm load
Frequency Tuning (EFC)
Tuning Range Fixed OCXO; No adjust
Tuning Range
±1.0
±2.0
±3.0
±4.0
±5.0
±8.0
±10.0
±12.0
ppm
with 10 to 14.99 MHz
with 15 to 20.48 MHz
with 20.5 to 49.99 MHz
with 50 to 80 MHz
Control Voltage Range 0 Vs VDC
Tuning Slope Positive
Oven Alarm Logic 4.0
2.6
0.4
VDC
During Warmup
Vs=5.0 Vdc After Warmup
Vs=3.3 Vdc After Warmup
Additional Parameters
Phase Noise @ 10 MHz (Typical)
-120
-140
-145
-155
-155
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
Phase Noise @ 20 MHz (Typical)
-100
-130
-140
-145
-150
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
3 of 5
Additional Parameters (continued)
Parameter Min Typical Max Units Condition
Allan Deviation 0.2 ppb Tau = 1 sec to 10 sec (10 to 20.49 MHz)
0.5 Tau = 1 sec to 10 sec (20.5 to 80 MHz)
Acceleration Sensitivity (10 MHz) 1.0 ppb/g Total Gamma
Weight 5 g
Absolute Maximum Ratings
Supply Voltage 5.5 VDC with Vs=5 V
5.5 with Vs=3.3 V
Output Load 30 pF
Operable temperature range -55 +85 °C
Storage temperature range -55 +85 °C
Standard Environmentals
Vibration - Sine MIL-STD-202, Method 204, Condition D (20 G, 10Hz-2000Hz)
Vibration - Random MIL-STD-202, Method 214, Condition I-F (20 Grms, 10Hz-2000Hz)
Shock MIL-STD-202, Method 213, Condition E (1000 G, 0.5ms, halfsine)
Solderability MIL-STD-202, Method 208
Type A
Code Height “H” Pin Length “L
0 7.62 5.08
Pin Connections
1 EFC \ No Connect \ Oven Monitor
7 Ground (Case)
8 RF Output
14 Supply Voltage Input
Outline Drawing / Enclosure
Dimensions in mm (inches)
Frequency Stabilities1 (continued)
Parameter Min Typical Max Units Condition
Additional Parameters
Phase Noise @ 50 MHz (Typical)
-80
-110
-130
-135
-140
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
4 of 5
Recommended Reow Prole
Prole Feature Sn-Pb Assembly Prole Feature Sn-Pb Assembly
Average ramp-up rate (TL to Tp) 3°C/second max. Time 25°C to Peak Temperature 4 minutes max.
135°c
155°c
60-90 seconds
Time maintained above
- Temperature (TL)
- Time (tL)
183°C
45-60 seconds
Tsmax to TL - Ramp-up Rate 3°C/second max.
183°C
45-60 seconds
Time within 5°C of actual
Peak Temperature (tp)
10-20 seconds max.
Type B
Code Height “H” Pin Length “L
1 8.9 (0.35”) NA
2 10.2 (0.4”) NA
Pin Connections
1 EFC \ No Connect \ Oven Monitor
7 Ground (Case)
8 RF Output
14 Supply Voltage Input
Outline Drawing / Enclosure
Dimensions in mm (inches)
Critical Zone
TL to Tp
Ramp up
Ramp dow n
t 25°C to peak
T
p
Temperature
T
L
25
Time
Ts
min
Ts
ts
preheat
tp
PRECAUTION: Series shall not expose to temperature higher than 230°C. If exposing to temperature
higher than 230°C, stability and power consumption may permanently degrade.
Preheat -Temperature Min Tsmin)
-Temperature Min Tsmax)
-Time (min to max) (ts)
Time maintained above
- Temperature (TL)
- Time (tL)
Peak Temperature (Tp) max 220°C Ramp-down Rate 6°C/second max.
Note: All temperatures refer to topside of the package, measured on the package body surface.
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
5 of 5
Temperature Range and Stability Table
Stability/Temperature A: -55°C to +85°C E: -40°C to +85°C J: -20°C to +70°C
758: (±75ppb) 10.2 (0.4”) NA 10 to 20 MHz
107: (±100ppb) 10 to 40 MHz 10 to 40 MHz 10 to 65 MHz
157: (±150ppb) 10 to 65 MHz 10 to 65 MHz 10 to 65 MHz
257: (±250ppb) 10 to 80 MHz 10 to 80 MHz 10 to 80 MHz
507: (±500ppb) 10 to 80 MHz 10 to 80 MHz 10 to 80 MHz
147: (±140ppb(ST3)) 10 to 65 MHz 10 to 65 MHz 10 to 65 MHz
Frequency Range
10 to 20 MHz
10 to 40 MHz
10 to 65 MHz
10 to 80 MHz
Ordering Information
EX - 400 0 - D A J - 107 0 - 10M0000000
Product Family
EX: EMXO
Package
13x20mm
Height
0: A 7.62mm (HCMOS only)
1: B 8.9mm (HCMOS only)
2: B 10.2mm (Sinewave only)
Supply Voltage
D: +5V
E: +3.3V
Stability Code
758: ±75ppb
107: ±100ppb
157: ±150ppb
257: ±250ppb
507: ±500ppb
147: ±140ppb(ST3)
Frequency
Frequency Control
0: Fixed Frequency (HCMOS)
1: Fixed Frequency (0 dBm)
2: Fixed Frequency (+3 dBm)
3: Electrical Tuning (HCMOS)
4: Electrical Tuning (0 dBm)
5: Electrical Tuning (+3 dBm)
6: Oven Alarm Option (HCMOS)
7: Oven Alarm Option (0 dBm)
8: Oven Alarm Option (+3 dBm)
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
For Additional Information, Please Contact
USA:
Vectron International
267 Lowell Road, Unit 102
Hudson, NH 03051
Tel: 1.888.328.7661
Fax: 1.888.329.8328
Europe:
Vectron International
Landstrasse, D-74924
Neckarbischofsheim, Germany
Tel: +49 (0) 3328.4784.17
Fax: +49 (0) 3328.4784.30
Asia:
Vectron International
68 Yin Cheng Road(C), 22nd Floor
One LuJiaZui
Pudong, Shanghai 200120, China
Tel: 86.21.6194.6886
Fax: 86.21.6194.6699
RF Output Code
A: HCMOS
E: Sinewave
Temperature Range
A: -55°C to +85°C
E: -40°C to +85°C
J: -20°C to +70°C
Notes:
1. Contact factory for improved stabilities or additional product options. Not all options and codes are available at all
frequencies.
2. Unless other stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency
control voltage, load, temperature (25°C).
3. Phase noise degrades with increasing output frequency.
4. Subject to technical modication.
5. Contact factory for availability.
Rev: 11/4/2014 JV
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Vectron:
EX-4001-DAE-1070-10M0000000