Surge Arrester A61-A350XF
2-Electrode-Arrester Ordering code: B88069X4470C102
AB E / AB PM Issue 02, 06.03.2003
Page 1 of 2
DC spark-over voltage 1) 2)
350
± 20 V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 750
< 680
< 900
< 750
V
V
V
V
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current (wave 8/20 µs) 3) 10
20 kA
kA
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles) 10
40 A
A
Service life
300 operations 10/1000 µs 100 A
Insulation resistance at 100 Vdc > 10
GΩ
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
< 20
< 0.5
~ 60
V
A
V
Weight ~ 1.5 g
Storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red
350 YY O
350 - Nominal voltage
YY - Year of production
O - Non radioactive
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
3) After load: Insulation resistance >108 Ω,
Impulse spark-over voltage < 1000 V
Terms in accordance with ITU-T Rec. K.12 and DIN 5784 5/VDE0845
http://store.iiic.cc/