Digital Controllers E5ER CSM_E5ER_DS_E_4_2 E5ER Digital Controllers offer high speed, high precision, and multiple I/O and use a 5-digit, 3-row LCD display for high visual clarity. * A short sampling period of 50 ms enables use in applications requiring high-speed response. * PV, SP, and MV data is displayed simultaneously in a 3-row, negative LCD display with a backlight. * Multipoint control, cascade control, and proportional control are possible with a single Controller. * When using models with CompoWay/F communications, initial settings can be downloaded and settings can be masked using Support Software (CX-Thermo version 4.0 or higher). * Equipped with calculation functions as a standard (e.g., square root calculation and broken-line approximation). * DeviceNet Communications Data setting and monitoring can be performed without any special programming. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All E5@R Models. Refer to E5AR/E5ER Operation for operating procedures. Model Number Structure Model Number Legend E5ER-@@@@@@@@@-@@@ 1 2 3 4 5 6 7 8 9 10 1. Constant values/Program None: Constant values 2. Control method Blank: Standard, or heating/cooling control P: Position-proportional control 3. Output 1 R: DPST-NO relay outputs Q: Pulse voltage and pulse voltage/current outputs C: Current and current outputs 4. Output 2 Blank:None R: Relay Q: Pulse voltage and pulse voltage/current outputs C: Current and current outputs 5. Auxiliary outputs Blank:None 4: 4PST-NO relay outputs T: 2 transistor outputs 6. Optional function 1 Blank:None 3: RS-485 communications 7. Optional function 2 Blank:None D: 4 event inputs 8. Input 1 B: Universal-input and 2 event inputs F: Universal-input and FB W: Universal-input and universal-input 9. Input 2 Blank:None W: Universal-input and universal-input 10.Communications Method Blank:None FLK: CompoWay/F DRT: DeviceNet Note: The above model number legend is intended as a functional description of models. Not all possible combinations of functions are available. Confirm model availability in Ordering Information when ordering. The CX-Thermo Support Software (version 4.0 or higher) can be used to easily set parameters in conversational form. Note: Be sure to read the precautions for correct use and other precautions in the following user's manual before using the Digital Controller. E5AR/E5ER Digital Controller User's Manual (Cat. No. Z182) E5AR/E5ER Digital Controller DeviceNet Communication User's Manual (Cat. No. H124) 1 E5ER Ordering Information Digital Controllers Standard Controllers Size 48 x 96 mm Control type Basic control (1 loop) Control mode Outputs (control/ transfer) Single-loop standard control 2 points: Pulse voltSingle-loop heating and cooling control age and Pulse voltage/current Optional functions Auxiliary outputs (SUB) Event inputs Serial communications 4 2 No 2 points: Current and Current RS-485 2 points: Current and Current 2 6 (See note 3.) E5ER-QT3DB-FLK (See note 2.) E5EAR-CT3DBFLK (See note 2.) 4 points: Pulse voltage and Pulse voltage/current and Current (2 points) 4 2 points: Pulse voltage and Pulse voltage/current 2 4 (See note 3.) 2 E5ER-QC43B-FLK RS-485 2 points: Current and Current Position-pro- Single-loop position-proportional control Relay output portional con- (See note 4.) (1 open, 1 closed) trol (1 loop) Relay output (1 open, 1 closed) and 1 current (transfer) output E5ER-Q43B-FLK (See note 2.) E5ER-C43B-FLK (See note 2.) 2 points: Current and Current 2-loop control 2-loop standard control Single-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control E5ER-Q4B E5ER-C4B 2 points: Pulse voltage and Pulse voltage/current 2 points: Pulse voltage and Pulse voltage/current Model E5ER-QT3DW-FLK E5ER-CT3DW-FLK 2 4 (See note 3.) No E5ER-PRTDF 4 RS-485 E5ER-PRQ43F-FLK No Note 1: Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC. 2. These models are for 100 to 240 VAC only. 3. The auxiliary outputs are transistor outputs. 4. Can be switched between close control and floating control. 2 E5ER DeviceNet-compatible Controllers Size 48 x 96 mm Control type Control mode Basic control Single-loop standard control (1 loop) Single-loop heating and cooling control Outputs (control/ transfer) Optional functions 2 points: 2 (See Pulse voltage note 2.) Pulse voltage/current 2 Yes 2 points: Current and Current 2-loop control 2-loop standard control Single-loop heating and cooling control Single-loop cascade control Single-loop standard control with remote SP Single-loop proportional control Position-pro- Single-loop position-proportional control portional (See note 3.) control (1 loop) E5ER-QTB-DRT E5ER-CTB-DRT 2 points: 2 (See Pulse voltage note 2.) Pulse voltage/current None Yes 2 points: Current and Current Relay output (1 open, 1 closed) Model Auxiliary Event DeviceNet outputs inputs communi(SUB) cations E5ER-QTW-DRT E5ER-CTW-DRT 2 (See note 2.) None Yes E5ER-PRTF-DRT Note: 1. Specify the power supply specifications when ordering. Model numbers for 100 to 240 VAC are different from those for 24 VAC/VDC. 2. The auxiliary outputs are transistor outputs. 3. Can be switched between close control and floating control. Inspection Results Accessories (Order Separately) The Inspection Report can be ordered at the same time as the Digital Controller using the following model number. Terminal Cover (Sold Separately) Inspection Report (Sold Separately) Descriptions Inspection Report for E5ER Model E5ER-K Descriptions Terminal Cover for E5ER Model E53-COV15 Rubber Packing Model Y92S-P5 Note: The Rubber Packing is provided with the Digital Controller. 3 E5ER Specifications Ratings Supply voltage (See note 1.) Item 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 17 VA max. (with maximum load) Sensor input (See note 2.) Thermocouple: K, J, T, E, L, U, N, R, S, B, W Platinum resistance thermometer: Pt100 Current input: 4 to 20 mA DC, 0 to 20 mA DC (including remote SP input) Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (including remote SP input) (Input impedance: 150 for current input, approx. 1 M for voltage input) 11 VA/7 W max. (with maximum load) Control output Voltage (pulse) output 12 VDC, 40 mA max. with short-circuit protection circuit Current output 0 to 20 mA DC, 4 to 20 mA DC; load: 500 max. (including transfer output) (Resolution: Approx. 54,000 for 0 to 20 mA DC; Approx. 43,000 for 4 to 20 mA DC) Relay output Position-proportional control type (open, closed) N.O., 250 VAC, 1 A (including inrush current) Auxiliary output Relay Output N.O., 250 VAC, 1 A (resistive load) Transistor Output Maximum load voltage: 30 VDC; Maximum load current: 50 mA; Residual voltage: 1.5 V max.; Leakage current: 0.4 mA max. Potentiometer input 100 to 2.5 k Event input Contact Input ON: 1 k max.; OFF: 100 k min. No-contact Input ON: Residual voltage of 1.5 V max.; OFF: Leakage current of 0.1 mA max. Short-circuit: Approx. 4 mA Remote SP input Refer to the information on sensor input. Transfer output Refer to the information on control output. Control method 2-PID or ON/OFF control Setting method Digital setting using front panel keys or setting using serial communications Indication method 7-segment digital display and single-lighting indicator Character Height PV: 9.5 mm; SV: 7.2 mm; MV: 7.2 mm Other functions Depends on model. Ambient operating temperature -10 to 55C (with no icing or condensation) For 3 years of assured use: -10 to 50C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature -25 to 65C (with no icing or condensation) Note 1: The supply voltage (i.e., 100 to 240 VAC or 24 VAC/VDC) depends on the model. Be sure to specify the required type when ordering. 2: The Controller is equipped with multiple sensor input. Temperature input or analog input can be selected with the input type setting switch. There is basic insulation between power supply and input terminals, power supply and output terminals, and input and output terminals. 3: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All E5@R Models.) Input Ranges Platinum Resistance Thermometer, Thermocouple, Current, or Voltage Input Input type Name Temperature Range (C) Thermocouple Platinum Resistance Thermometer Pt100 2300 1800 1300 900 800 700 600 400 200 100 0 -100 -200 Setting K J T E U N R S B 1700.0 1700.0 1800.0 W W/Re 5-26 Voltage [mA] [V] 2300.0 1300.0 1300.0 850.0 850.0 850.0 500.0 20 to 20 to 4 0 600.0 400.0 400.0 400.0 5 to 1 5 to 0 10 to 0 17 18 19 150.00 100.0 0.0 -200.0 -150.00 -200.0 0 1 2 -20.0 -100.0 -20.0 3 4 5 -100.0 -200.0 6 7 Minimum setting unit 0.1C 0.01C (SP and alarm) Input type setting switch L Current 8 0.1C -200.0 -200.0 9 10 0.0 0.0 11 12 0.0 13 14 15 16 (Depends on scaling and number of decimal places.) TC.PT Set to TC.PT. IN1 TYPE ANALOG TC.PT Set to ANALOG. IN1 TYPE ANALOG The shaded area indicates the setting status at the time of purchase. 4 E5ER Characteristics Indication accuracy Thermocouple input with cold junction compensation: (0.1% of PV or 1C, whichever is greater) 1 digit max. (See note 1.) Thermocouple input without cold junction compensation: (0.1% FS or 1C, whichever is smaller) 1 digit (See note 2.) Analog input: 0.1% FS 1 digit max. Platinum resistance thermometer input: (0.1% of PV or 0.5C, whichever is greater) 1 digit max. Position-proportional potentiometer input: 5% FS 1 digit max. Control mode Standard control (heating or cooling control), heating/cooling control, standard control with remote SP (2-input models only), heating/cooling control with remote SP (2-input models only), cascade standard control (2-input models only), cascade heating/cooling control (2-input models only), proportional control (2-input models only), position-proportional control (control-valve control models only) Influence of temperature Thermocouple input (R, S, B, W): (1% of PV or 10C, whichever is greater) 1 digit max. Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. K-type thermocouple at -100C max.: 10C max. Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max. Analog input: (1%FS) 1 digit max. Influence of temperature Control period 0.2 to 99.0 s (in units of 0.1 s) for time-proportioning control output Proportional band (P) 0.00% to 999.99% FS (in units of 0.01% FS) Integral time (I) 0.0 to 3,999.9 s (in units of 0.1 s) Derivative time (D) 0.0 to 3,999.9 s (in units of 0.1 s) Hysteresis 0.01% to 99.99% FS (in units of 0.01% FS) Manual reset value 0.0% to 100.0% (in units of 0.1% FS) Alarm setting range -19,999 to 99,999 EU (See note 3.) (The decimal point position depends on the input type and the decimal point position setting.) Input sampling period 50 ms Insulation resistance 20 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between charged terminals of different polarities) Vibration resistance 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions Shock resistance 100 m/s2, 3 times each in X, Y, and Z directions Inrush current 100 to 240-VAC models: 50 A max. 24 VAC/VDC models: 30 A max. Weight Controller only: Approx. 330 g; Mounting bracket: Approx. 60 g; Terminal cover: Approx. 16 g Degree of protection Front panel: NEMA4X for indoor use (equivalent to IP66); Rear case: IP20; Terminals: IP00 Memory protection Non-volatile memory (number of writes: 100,000) Applicable standards UL61010C-1, CSA C22.2 No. 1010-1 EN61010-1 (IEC61010-1): Pollution degree 2/overvoltage category 2 EMC EMI: EN61326 Radiated Interference Electromagnetic Field Strength: EN55011 Group 1 Class A Noise Terminal Voltage: EN55011 Group 1 Class A EMS: EN61326 ESD Immunity: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) 10 V/m (amplitude-modulated, 80 MHz to 1 GHz, 1.4 GHz to 2 GHz) (level 3) 2 kV power line (level 3) 2 kV output line (relay output) (level 4) 1 kV measurement line, I/O signal line (level 4) 1 kV communications line (level 3) Conducted Disturbance Immunity: EN61000-4-6: 3 V (0.15 to 80 MHz) (level 3) Surge Immunity: EN61000-4-5: 1 kV line to line (power line, output line (relay output)) (level 2) 2 kV line to ground (power line, output line (relay output)) (level 3) Power Frequency Magnetic Field Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous field Voltage Dip/Interrupting Immunity: EN61000-4-11: 0.5 cycle, 100% (rated voltage) Electromagnetic Immunity: EN61000-4-3: Burst Noise Immunity: EN61000-4-4: Note: 1. K-, T-, or N-type thermocouple at -100C max.: 2C 1 digit max. U- or L-type thermocouple: 2C 1 digit max. B-type thermocouple at 400C max.: No accuracy specification. R- or S-type thermocouple at 200C max.: 3C 1 digit max. W-type thermocouple: (0.3% of PV or 3C, whichever is greater) 1 digit max. 2. U- or L-type thermocouple: 1C 1 digit R- or S-type thermocouple at 200C max.: 1.5C 1 digit 3. "EU" (Engineering Unit) represents the unit after scaling. If a temperature sensor is used it is either C or F. 4. Conditions: Ambient temperature from -10 to 23 to 55C and voltage of -15% to 10% of rated voltage. 5 E5ER Communications Specifications Transmission path connection Multiple points Communications method RS-485 (two-wire, half duplex) Synchronization method Start-stop synchronization Baud rate 9,600, 19,200, or 384,000 bps Transmission code ASCII Data bit length 7 or 8 bits Stop bit length 1 or 2 bits Error detection Vertical parity (none, even, odd) Block check character (BCC): CompoWay/F CRC-16: Modbus Flow control None Interface RS-485 Retry function None Communications buffer 217 bytes Communications response send wait time 0 to 99 ms, Default: 20 ms DeviceNet Item Specifications Communications protocol Conforms to DeviceNet Communications functions Remote I/O communications * Master-slave connections (polling, bit-strobe, COS, or cyclic) * Conform to DeviceNet specifications. I/O allocations * Can allocate any I/O data from the Configurator. * Can allocate any data, such as parameters specific to the Devicenet, and the Digital Controller variable area. * Up to 2 blocks for the IN Area, up to a total of 100 words. * One block for the OUT Area, up to 100 words (first word is always allocated to Output Enable Bits). Message communications * Explicit message communications * CompoWay/F communications commands can be sent (commands are sent in explicit message format). Connection format Combination of multidrop and T-branch connections (for trunk and drop lines) Baud rate DeviceNet: 500, 250, or 125 kbps, or automatic detection of master baud rate Communications media Special 5-wire cable (2 signal lines, 2 power lines, and 1 shield line) Communications distance Baud rate Network length Drop line length Total drop line length 500 kbps 100 m max. (100 m max.) 6 m max. 39 m max. 250 kbps 250 m max. (100 m max.) 6 m max. 78 m max. 125 kbps 500 m max. (100 m max.) 6 m max. 156 m max. The values in parentheses apply when Thin Cables are used. Supply voltage DeviceNet power supply: 24 VDC Allowable voltage range DeviceNet power supply: 11 to 25 VDC Current consumption 50 mA max. (24 VDC) Maximum number of nodes that can be connected 64 (includes Configurator when used) Maximum number of slaves that can be connected 63 Error control CRC error detection Power supply Power supplied from DeviceNet communications connector. 6 E5ER Wiring Terminals E5ER Standard Controller Connections E5ER-Q4B E5ER-C4B - + + - B A E5ER-AB-500 24 VAC/DC 100-240 VAC E53-ARR4 Auxiliary outputs B (Relay outputs) 1 Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) 2 1 COM 3 4 2 SUB1 3 SUB2 5 6 1 4 5 6 COM A E5ER-AB-500 24 VAC/DC 100-240 VAC - + + - Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) SUB3 SUB4 1 COM 3 4 2 SUB1 3 SUB2 5 6 1 4 5 6 COM 2 3 4 3 4 5 6 5 6 C D E 2 OUT2 + Voltage output 3 12 V 40 mA 4 OUT1 Voltage output + 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) 2 COM 3 + TC PT 2 OUT2 Current output + 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. 4 (Switching by output + type setting) 5 OUT1 6 Current output 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) 4 5 6 E - + V 1 1 EV2 - I (Current) (Voltage) (Thermocouple) (Resistance thermometer) E5ER-Q43B-FLK 1 2 EV2 3 COM + - - + V I 4 5 6 E + TC PT (Current) (Voltage) (Thermocouple) (Resistance thermometer) E5ER-C43B-FLK E5ER-AB-500 A 100-240 VAC E53-ARR4 Auxiliary outputs B (Relay outputs) B 1 E53-ARQC3 + B(+) 1 RS-485 A(-) - 2 OUT2 + Voltage output 3 12 V 40 mA OUT1 4 Voltage output + 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. C (Switch using output type setting.) SUB4 E5ER-AB-500 Event inputs EV1 E53-ARCC + - SUB3 C D E E5ER-AB-500 Event inputs EV1 1 E53-ARR4 Auxiliary outputs B (Relay outputs) 2 2 E53-ARQC B 1 2 1 COM 3 4 2 SUB1 3 SUB2 5 6 1 4 5 6 COM E5ER-AB-500 A 100-240 VAC 1 SUB3 SUB4 2 1 COM 3 4 2 SUB1 3 SUB2 5 6 1 4 5 6 COM 2 2 3 4 3 4 5 6 5 6 E5ER-AB-500 Event inputs EV1 1 2 COM 3 PT 4 5 6 E + V E53-ARCC3 EV2 + I SUB3 SUB4 C D E C D E - E53-ARR4 Auxiliary outputs B (Relay outputs) B + TC (Current) (Voltage) (Thermocouple) (Resistance thermometer) RS-485 B(+) + 1 A(-) - 2 OUT2 Current output + 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. 4 (Switch using output + type setting.) 5 OUT1 6 Current output 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) E5ER-AB-500 Event inputs EV1 2 COM 3 + - - I + V 1 EV2 - PT + TC 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermocouple) 7 E5ER E5ER-QT3DB-FLK E5ER-AB-500 E5ER-CT3DB-FLK A 100-240 VAC E53-ARB4 B 1 2 3 4 E53-ARQC3 + B(+) 1 RS-485 A(-) 2 OUT2 + 3 Voltage output 12 V 40 mA 4 OUT1 + Voltage output 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. C (Switch using output type setting.) 5 6 1 2 EV3 2 2 EV4 3 EV5 4 5 6 3 4 COM C D E 2 SUB1 + 3 - 4 5 6 D D + SUB2 - 1 EV2 2 COM 3 PT 4 5 6 E + V I + TC (Current) (Voltage) (Thermocouple) (Resistance thermometer) Auxiliary outputs (Transistor outputs) SUB2 2 EV4 3 EV5 4 5 6 COM C D E 1 3 - 4 5 6 D D - EV3 5 6 + + B 1 EV6 E5ER-AB-500 Event inputs EV1 2 SUB1 Event inputs 3 4 E53-ART2 + - 5 6 1 2 E53-ARCC3 + B(+) 1 RS-485 A(-) - 2 OUT2 + Current output 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. 4 (Switch using output + 5 type setting.) OUT1 6 Current output 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) 5 6 E5ER-AB-500 Event inputs EV1 E53-ARB4 B 1 3 4 1 A 100-240 VAC B 1 EV6 E53-ART2 Auxiliary outputs (Transistor outputs) E5ER-AB-500 Event inputs 2 COM 3 + - - I + V 1 EV2 - PT + TC 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) E5ER-QC43B-FLK E5ER-AB-500 24 VAC/DC 100-240 VAC A E53-ARR4 Auxiliary outputs B (Relay outputs) B - + 1 + - 2 1 COM 3 4 2 SUB1 3 SUB2 5 6 1 2 4 5 6 COM Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) E53-ARQC3 + B(+) 1 RS-485 A(-) - 2 OUT2 + Voltage output 3 12 V 40 mA 4 OUT1 Voltage output + 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. C (Switch using output type setting.) SUB3 SUB4 3 4 5 6 C D E E53-ARCC 1 2 OUT4 Current output + 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. 4 (Switch using output + type setting.) 5 OUT3 6 Current output 4-20 mA DC, 500 max. D 0-20 mA DC, 500 max. (Switch using output type setting.) E5ER-AB-500 Event inputs EV1 2 COM 3 + - - I + V 1 EV2 - PT + TC 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) 8 E5ER 1 + - 2 Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) B 3 4 5 6 1 2 E53-ARQC3 + B(+) 1 RS-485 A(-) - 2 OUT2 + 3 Voltage output 12 V 40 mA 4 OUT1 + Voltage output 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. C (Switch using output type setting.) Event inputs B 1 EV3 2 EV4 3 EV5 4 5 6 EV6 COM E5ER-AW-500 24 VAC/DC 100-240 VAC C D E 1 - - 2 + SUB2 - 4 5 6 D D Input 1 I + V PT - - SUB1 3 + + - 2 + TC 3 - + I V PT + TC B 1 2 EV3 2 3 4 EV4 3 EV5 5 6 1 EV6 4 5 6 1 - E53-ARRR 1 Relay output 250 VAC 1 A B Event inputs + Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) OUT1 A + 4 5 6 C EV3 2 EV4 3 EV5 4 5 6 EV6 COM 5 6 C D E E5ER-AW-500 1 Input 2 SUB1 + 3 - 4 5 6 D D + SUB2 - Input 1 1 - I + V PT - 2 + TC 3 + TC + I - V PT 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) COM - OUT1 O 1 W 2 C + 3 - 4 5 6 D D A 1 2 3 4 5 6 C Relay output 250 VAC 1 A + - - I + V + PT TC 2 3 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) E53-ARR4 Auxiliary outputs B (Relay outputs) 2 1 COM 3 4 2 SUB1 3 SUB2 5 6 1 4 5 6 COM SUB3 SUB4 2 Closed 3 4 Open 5 6 C D E 1 1 B 1 E53-ARQC E5ER-PAF-500 Potentiometer E53-ART2 + + OUT2 C D E - + E53-ARRR3 + B(+) RS-485 A(-) 5 6 Auxiliary outputs (Transistor outputs) - Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) 3 4 Open SUB2 B 1 3 4 E5ER-PAF-500 24 VAC/DC 100-240 VAC 2 Closed SUB1 5 6 1 2 Event inputs E5ER-PRQ43F-FLK E53-ARB4 - 3 3 4 2 (Current) (Voltage) (Thermocouple) (Resistance thermometer) E5ER-PAF-500 24 VAC/DC 100-240 VAC OUT2 + Auxiliary outputs (Transistor outputs) 4 5 6 E E5ER-PRTDF 2 2 E53-ART2 + Input 2 - B(+) 1 RS-485 A(-) - 2 OUT2 + Current output 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. 4 (Switch using output + type setting.) 5 OUT1 6 Current output 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) 5 6 1 + E53-ARCC3 E5ER-AW-500 Auxiliary outputs (Transistor outputs) 1 Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) 3 4 E53-ART2 + E53-ARB4 B A - - + + A - E5ER-CT3DW-FLK (2-loop Control) E53-ARB4 + E5ER-AW-500 24 VAC/DC 100-240 VAC - E5ER-QT3DW-FLK (2-loop Control) 2 OUT4 + Voltage output 3 12 V 40 mA 4 OUT3 + Voltage output 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. D 0-20 mA DC, 500 max. (Switch using output type setting.) E5ER-PAF-500 Potentiometer O W C + - - I + V + PT TC 1 2 3 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) 9 E5ER E5ER DeviceNet-compatible Controller Connections E5ER-CTB-DRT 3 4 E53-ARQC 1 2 OUT2 + Voltage output 3 12 V 40 mA 4 OUT1 Voltage output + 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. C (Switch using output type setting.) SUB1 + SUB2 - 2 OUT2 + Current output 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. - 4 (Switch using output + type setting.) 5 OUT1 6 Current output 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) 5 6 C D E E5ER-AB-500 Event inputs EV1 1 3 4 5 6 D D 2 COM 3 PT 4 5 6 E - - I - + V + TC A + 1 SUB1 + - 2 1 2 OUT2 + 3 Voltage output 12 V 40 mA 4 OUT1 + Voltage output 5 12 V 40 mA or Current output 6 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. C (Switch using output type setting.) SUB2 DeviceNet Connector Red (V+) White (CAN H) - (Shield) Blue (CAN L) Black (V-) 3 4 5 6 1 2 3 4 5 6 C D E Input 2 1 + SUB2 - 4 5 6 D D Input 1 I + V PT - - - + SUB1 3 - 2 + TC 3 - + I V PT Input 1 1 - I + V PT - 2 + TC 3 - + I - V PT + TC 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) + TC 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) A - + 1 + - 2 Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) Auxiliary outputs (Transistor outputs) 1 + 3 - 4 5 6 D D + SUB2 DeviceNet Connector Red (V+) White (CAN H) - (Shield) Blue (CAN L) Black (V-) 3 4 5 6 1 2 3 4 5 6 C D E Input 2 1 - 2 SUB1 E53-ARDRT B E5ER-AW-500 E53-ART2 - Input 2 E5ER-AW-500 24 VAC/DC 100-240 VAC 2 OUT2 + Current output 3 4-20 mA DC, 500 max. 0-20 mA DC, 500 max. - 4 (Switch using output + type setting.) 5 OUT1 6 Current output 4-20 mA DC, 500 max. C 0-20 mA DC, 500 max. (Switch using output type setting.) 2 + - 1 - 1 4 5 6 D D E53-ARCC + Auxiliary outputs (Transistor outputs) C D E E5ER-CTW-DRT (2-loop Control) E5ER-AW-500 E53-ART2 3 + E53-ARDRT B 5 6 2 E5ER-QTW-DRT (2-loop Control) - 3 4 1 + (Current) (Voltage) (Thermocouple) (Resistance thermometer) E5ER-AW-500 24 VAC/DC 100-240 VAC 5 6 1 2 E5ER-AW-500 Auxiliary outputs (Transistor outputs) 1 DeviceNet Connector Red (V+) White (CAN H) - (Shield) Blue (CAN L) Black (V-) 3 4 E53-ART2 EV2 + E53-ARQC 2 1 3 4 Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) - E53-ARCC 2 + + Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) 5 6 1 2 E53-ART2 Auxiliary outputs (Transistor outputs) 1 E53-ARDRT B - Input 1 I + V PT - - 2 + + - A - - + Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) E5ER-AW-500 24 VAC/DC 100-240 VAC DeviceNet Connector Red (V+) White (CAN H) - (Shield) Blue (CAN L) Black (V-) + 1 B - + + A - E53-ARDRT + E5ER-AB-500 24 VAC/DC 100-240 VAC - E5ER-QTB-DRT 2 + TC 3 - + I - V PT + TC 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) 10 E5ER E5ER-PRTF-DRT E5ER-PAF-500 24 VAC/DC 100-240 VAC + 1 + - 2 Input power supply depends on the model. 100 to 240 VAC or 24 VAC/DC (no polarity) 1 2 OUT1 3 4 5 6 C E53-ARDRT B DeviceNet Connector Red (V+) White (CAN H) - (Shield) Blue (CAN L) Black (V-) 3 4 5 6 1 E53-ARRR OUT2 A - Relay output 250 VAC 1 A 2 3 4 Closed 5 6 Open C D E E5ER-PAF-500 Potentiometer E53-ART2 Auxiliary outputs (Transistor outputs) O 1 W 2 SUB1 + 3 - 4 5 6 D D + SUB2 - C + - - I + V + PT TC 1 2 3 4 5 6 E (Current) (Voltage) (Thermocouple) (Resistance thermometer) 11 E5ER Nomenclature E5ER Operation Indicators MS/NS Indicators Top: MS Bottom: NS No. 1 Display No. 2 Display No. 3 Display Mode Key Down Key Level Key Up Key Function Key 1/ Auto/Manual Key DeviceNet communications connector Used to connect the DeviceNet communications cables. The DeviceNet communications power is also supplied through this connector. The connector included with the DeviceNet-compatible Controllers is the FKC 2.5/5-STF-5.08 AU M (PHOENIX CONTACT). Function Key 2/ Channel Key Dimensions Note: All units are in millimeters unless otherwise indicated. E5ER 110 95 (99)* 11.5 48 3 Terminal cover (E53-COV15; sold separately) 2 1 2 3 4 5 6 96 1 111 2 3 4 5 6 Mounting Bracket (Accessory) Crimp terminal size: M3 * The value in parentheses are for DeviceNet-compatible Controllers. Panel Cutouts 45 +0.6 0 60 min. 120 min. * Recommended panel thickness is 1 to 8 mm. * Group mounting is not possible. (Maintain the specified mounting space between Controllers.) 92 +0.8 0 * When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications. 12 E5ER Accessories (Order Separately) Terminal Cover E53-COV15 (for E5ER) 48 95 28.5 10.1 Unit Label Sheet Y92S-L1 11.8 4.8 Rubber Packing Y92S-P5 (for DIN48 x 96) Order the Rubber Packing separately if it becomes lost or damaged. (Refer to page 3.) The Rubber Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA4. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Rubber Packing does not need to be attached if a waterproof structure is not required. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 13 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E5ER-C43B-FLK AC100-240V E5ER-C4B AC100-240 E5ER-C4B AC/DC24 E5ER-CT3DB-FLK AC100-240V E5ERCT3DW-FLK AC100-240 E5ER-CT3DW-FLK AC/DC24 E5ER-CTW-DRT AC100-240V E5ER-PRQ43F-FLK AC100240 E5ER-PRQ43F-FLK AC/DC24 E5ER-PRTDF AC100-240 E5ER-PRTDF AC/DC24 E5ER-Q43B-FLK AC100-240V E5ER-Q4B AC100-240 E5ER-Q4B AC/DC24 E5ER-QC43B-FLK AC100-240 E5ER-QC43B-FLK AC/DC24 E5ERQT3DB-FLK AC100-240V E5ER-QT3DW-FLK AC100-240 E5ER-QT3DW-FLK AC/DC24 E5ER-QTB-DRT AC100240V E5ER-QTW-DRT AC100-240V E5ER-CTB-DRT AC100-240V E5ER-PRTF-DRT AC24V