40 Industrial Way East, Eatontown , NJ 07724 [USA]
Phone: (732) 460-0212, Fax: (732) 460-0214
www.aeroflex.com/acc, email: acc-sales@aeroflex.com
Parameter Specification Units
Frequency Range (min) 2 – 12 GHz
Sensitivity (min) 2000 mV/mW
Flatness vs. Frequency (max) 1.0 ±dB
Typical TSS -52 dBm
Nominal Video Capacitance 12 pF
Specifications:
Features:
• Contains hermetically sealed modules, inter-
nal RF matching, DC return, and RF bypass
capacitor.
• The video port is protected from static or
transient charges.
• Input impedance matching.
• Models may be chosen for broadband RF
performance of for optimized narrow bands
Revision Date: 2/23/2011
ACSP-2032
Bolt Channel Schottky Detector
Notes:
Maximum input power: +20dBm
Sensitivity is measured into an open circuit load
(>10k ohm).
Standard bias is 100uA.
Video capacitance is used for RF bypass. This value
can be changed if required for video response time.
Contact the factory for more information.
Environmental Specifications:
Designed to meet:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Shock: MIL-STD-202F, M213, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Vibration: MIL-STD-202F, M204, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
SCREENING:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65°C to +100°C, 10 cycles
OPTIONAL HIGH-REL SCREENING
(Ref MIL-PRF-38534):
Stabilization Bake per MIL-STD-883, Method 1008
Temperature Cycle per MIL-STD-883, Method 1010
Constant Acceleration per MIL-STD-883, Method
2001
Burn-in per MIL-STD-883, Method 1015
Leak Test per MIL-STD-883, Method 1014
External Visual per MIL-STD-883, Method 2009