http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THN 15 Series 15 Watt
Input Specifications
Input current at no load – 12 Vin 3.3 / 5 VDC models: 120 mA typ. / 90 mA typ.
24 / ±24 VDC models: 12 mA typ. / 17 mA typ.
other models: 30 mA typ.
– 24 Vin 3.3 / 5 VDC models: 50 mA typ. / 65 mA typ.
12 &15 VDC models: 20 mA typ
±5 & ±12 VDC models: 15 mA typ.
24 / ±24 VDC models: 10 mA typ / 12 mA typ.
– 48 Vin 3.3 / 5 VDC models: 25 mA typ. / 35 mA typ.
12, 15 & ±5 VDC models: 12 mA typ.
±12 VDC models: 15 mA typ.
±15 VDC models: 20 mA typ.
24 & ±24 VDC models: 10 mA typ.
Start-up voltage / 12 Vin models: 9.0 VDC / 8.0 VDC
under voltage shut down 24 Vin models: 18.0 VDC / 14.5 VDC
48 Vin models: 36.0 VDC / 30.5 VDC
Surge voltage 12 Vin models: 36 V max.
(100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reflected input ripple current 30 mA typ.
Conducted noise EN 55022 class A and B
with external components
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / surge (with external input capacitor) EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
– external input capacitor
Nippon chemi-con KY 220 µF, 100 V
Conducted immunity EN 61000-4-6, 3 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±1 %
Output voltage adjustment range 24 Vin models: –10 / +20 %
all other models: ±10 % only for single output models
see application note.
Regulation – Input variation (Vmin – Vmax) single output models: 0.2 % max.
dual output models: 0.5 % max.
– Load variation (0 – 100 %) single output models: 0.2 % max.
dual output models balanced load: 1.0 % max.
dual output models unbalanced load (25% /100%): 5.0 % max.
Minimum load not required
Ripple and noise (20 MHz bandwidth) 3.3/5.0 VDC models: 75 mVpk-pk with external capacitor
all other models: 100 mVpk-pk max. with external capacitor
see application note
Temperature coefficient ±0.02 %/K
Output current limitation typ. 150 % of Iout max., Hiccup
Short circuit protection continuous, automatic recovery
Over voltage protection 3.3 Vout models: 3.7 – 5.4 Vout
5 Vout models: 5.6 – 7.0 Vout
12 Vout models: 13.5 – 19.6 Vout
15 Vout models: 16.8 – 20.5 Vout
24 Vout models: 29.1 – 32.5 Vout
Start up time (nominal Vin and constant resistive load) 30 ms typ. (for power on and remote on)
Transient response setting time (25% load step chang) 250 µs typ.