86 SERIES Timer modules 86 SERIES 86.00 Timer modules for use in conjunction with relay & socket. 86.30 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module * Timer module type 86.00 for 90, 92, 96 * * series sockets and type 86.30 for 90, 92, 94, 95, 96, 97 series sockets Wide supply voltage range: 12...240 V AC/DC (86.00) 12...24 V AC/DC or 230...240 V AC (86.30) LED indicator * Time scale: from 0.05 s to 100 h * Multi-function * Plug-in for use with 90.02, 90.03, 92.03 and 86.00 96.04 sockets * Time scale: from 0.05 s to 100 h * Bi-function * Plug-in for use with 90.02, 90.03, 92.03, 94.P3, 94.P4, 94.02, 94.03, 94.04, 95.P3, 95.P5, 95.03, 95.05, 96.02, 96.04, 97.P1, 97.P2, 97.01 and 97.02 sockets AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off FE: Interval with control signal on and off AI: On-delay DI: Interval 86.30 Relay + socket Relay + socket Relay + socket Wiring diagram (without control signal) Wiring diagram (with control signal) Wiring diagram Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kW Breaking capacity DC1: 30/110/220 V A Minimum switching load H A See 56, 60 and 62 series relays Note: Do not use with relays 62.3x.x012.x300 and 62.3x.x012.x600 See 40, 44, 46, 55, 56, 60 and 62 series relays mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) Rated power AC/DC Operating range V AC (50/60 Hz) 12...240 12...24 110...125 230...240 V DC 12...240 12...24 -- -- W 1.2 0.15 V AC (50/60 Hz) 10.2...265 9.6...33.6 88...137 184...265 DC 10.2...265 9.6...33.6 -- -- Technical data X-2016, www.findernet.com Specified time range (0.05...1)s, (0.5...10)s, (5...100)s, (0.5...10)min, (5...100)min, (0.5...10)h, (5...100)h Repeatability% 1 1 Recovery time ms 50 50 Minimun control impulse ms 50 -- Setting accuracy full range % 5 5 See 56, 60 and 62 series relays See 40, 44, 46, 55, 56, 60 and 62 series relays -20...+50 -20...+50 IP 20 IP 20 Electrical life at rated load in AC1 Ambient temperature range Protection category cycles C Approvals (according to type) 1 86 SERIES 86 SERIES Timer modules Ordering information Example: 86 series multi-function timer module, (12...240)V AC/DC supply voltage. 8 6 . 0 0 . 0 . 2 4 0 . 0 Type 0 = Multi-function (AI, DI, SW, BE, CE, DE, EE, FE) 3 = Bi-function (AI, DI) No. of poles See 40, 44, 46, 55, 56, 60 and 62 series relays Poles for chosen relay/socket combination according to chart below 0 Supply version 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) Number of poles Relay type Socket type Timer module 1 40.31 95.P3/95.03 86.30 1 40.61 95.P5/95.05 86.30 1 46.61 97.P1/97.01 86.30 2 40.52/44.52/44.62 95.P5/95.05 86.30 2 46.52 97.P2/97.02 86.30 2 55.32 94.P4/94.02 86.30 2 56.32 96.02 86.30 2 60.12 90.02 86.00/86.30 2 62.32 92.03 86.00/86.30 3 55.33 94.P3/94.03 86.30 3 60.13 90.03 86.00/86.30 3 62.33 92.03 86.00/86.30 4 55.34 94.P4/94.04 86.30 4 56.34 96.04 86.00/86.30 Technical data EMC specifications Type of test Electrostatic discharge contact discharge air discharge Radio-frequency electromagnetic field (80 / 1000 MHz) Reference standard 86.00 86.30 EN 61000-4-2 4 kV n.a. EN 61000-4-2 8 kV 8 kV EN 61000-4-3 10 V/m 10 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV 2 kV Surges (1.2/50 s) on Supply terminals common mode EN 61000-4-5 4 kV 2 kV differential mode EN 61000-4-5 4 kV 1 kV Radio-frequency common mode (0.15 / 80 MHz) on Supply terminals EN 61000-4-6 10 V 10 V Radiated and conducted emission EN55022 class B class B Other data 86.00 86.30 Current absorption on signal control (B1) Power lost to the environment mA 1 without contact current with rated current W 0.1 (12 V) - 1 (230 V) See 56, 60 and 62 series relays -- 0.2 See 40, 44, 46, 55, 56, 60, 62 series relays Times scales NOTE: Time scales and functions must be set before energising the timer. To achieve the minimum time setting of 0.05 seconds it is necessary to use one of the functions with control signal. When setting very short times it may be necessary to take into account the operate time of the relay used. 2 X-2016, www.findernet.com H 0 Supply voltage 024 = (12...24)V AC/DC (86.30 only) 120 = (110...125)V AC (86.30 only) 240 = (12...240)V AC/DC (86.00 only) 240 = (230...240)V AC (86.30 only) Series Combinations 0 86 SERIES Timer modules 86 SERIES Functions LED Type 86.00 U = Supply voltage LED Type 86.30 S = Signal switch = Output contact Supply voltage NO output contact OFF Open ON Open ON Open (Timing in Progress) ON Closed Without control signal = Start via contact in supply line (A1). With control signal = Start via contact into control terminal (B1). Type 86.00 Wiring diagram (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. Without control signal (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off ). (BE) Off-delay with control signal. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. With control signal (CE) On- and off-delay with control signal. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Interval with control signal on. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. * * With DC supply, positive polarity has to be conneted to B1 terminal (according to EN 60204-1). Switch S should be exclusively used to provide the control signal to terminal B1. (Do not connect any other load at this point). H (EE) Interval with control signal off. Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. (FE) Interval with control signal on and off. Power is permenently applied to the timer. Both the opening and closing of the Signal Switch (S) initiates the transfer of the output contacts. In both instances the contacts reset after the delay period has elapsed. Wiring diagram Type 86.30 X-2016, www.findernet.com (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 3 86 SERIES 86 SERIES Sockets and accessories Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount For relay type Accessories Metal retaining clip 6-way jumper link Identification tag Timer module Technical data Double terminal A1 (for easy start connection) Rated values Dielectric strength Protection category Ambient temperature 90.03 Approvals (according to type): 90.02 Blue 60.12 90.02.0 Black 90.03 Blue 60.13 90.03.0 Black 090.33 090.06 090.00.2 86.00, 86.30 10 A - 250 V 2 kV AC IP 20 C -40...+70 Screw torque Nm 0.6 Wire strip length Max. wire size for 90.02 and 90.03 sockets mm 10 solid wire mm2 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 stranded wire 1 x 4 / 2 x 2.5 1 x 12 / 2 x 14 38 35.5 90.02 30.5 90.03 90.03 N T E O P A 6-way jumper link for 90.02 and 90.03 sockets Rated values 90.03 + 60.13 + 86.00 090.06 10 A - 250 V T EUR EUR H PEAN 26.9 33.5 90.02 O 21.6 4 34.8 3.2 77.5 20.4 81.1 PEAN 090.06 X-2016, www.findernet.com Approvals (according to type): 4 86 SERIES Sockets and accessories 92.03 Approvals (according to type): 86 SERIES Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Identification tag Timer modules Technical data Rated values Dielectric strength Protection category Ambient temperature Screw torque Wire strip length Max. wire size for 92.03 socket 92.03 Blue 62.32, 62.33 92.03.0 Black 092.71 092.00.2 86.00, 86.30 16 A - 250 V 6 kV (1.2/50 s) between coil and contacts IP 20 C -40...+70 (see diagram L92) Nm 0.8 mm 10 solid wire mm2 1 x 10 / 2 x 4 AWG 1 x 8 / 2 x 12 stranded wire 1x6/2x4 1 x 10 / 2 x 12 L 92 - Rated current vs ambient temperature 78.5 60.9 3.2 34.3 30.3 27 21.6 46.3 35.4 91.3 Rated current (A) 40 35.5 27 32 92.03 + 62.33 + 86.30 X-2016, www.findernet.com H 5 86 SERIES Sockets and accessories 86 SERIES 94.P4 Approvals (according to type): Certain relay/socket combinations 094.91.3 060.48 H Push-in terminal socket panel or 35 mm (EN 60715) rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 6-way jumper link Identification tag 2-way jumper link 2-way jumper link Marker tag holder Timer modules (see table below) Sheet of marker tags for plastic retaining and release clip 094.91.3 and for marker tag holder 097.00 , 48 tags, 6 x 12 mm for CEMBRE's thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Wire strip length mm Min. wire size for 94.P3 and 94.P4 sockets mm2 AWG Max. wire size for 94.P3 and 94.P4 sockets mm2 AWG R 94.P3 EAN OP EU N T T E P A 94.P3 Blue 55.33 94.P4 Blue 55.32, 55.34 094.71 094.91.3 094.56 094.00.4 094.52.1 097.52 097.00 86.30 060.48 10 A - 250 V 2 kV AC IP 20 -40...+70 8 solid wire 0.5 21 solid wire 2 x 1.5 / 1 x 2.5 2 x 18 / 1 x 14 stranded wire 0.5 21 stranded wire 2 x 1.5 / 1 x 2.5 2 x 18 / 1 x 14 94.P4 094.56 (blue) 10 A - 250 V 2-way jumper link for 94.P3 and 94.P4 sockets Rated values 094.52.1 10 A - 250 V 2-way jumper link for 94.P3 and 94.P4 sockets Rated values 097.52 10 A - 250 V Marker tag holder for 94.P3 and 94.P4 sockets 097.00 86 series timer modules (12...24)V AC/DC; Bi-function: AI, DI; (0.05 s...100 h) (110...125)V AC; Bi-function: AI, DI; (0.05 s...100 h) (230...240)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 EUR 6-way jumper link for 94.P3 and 94.P4 sockets Rated values OP EAN 094.56 094.52.1 097.00 86.30 6 Approvals (according to type): X-2016, www.findernet.com 097.52 86 SERIES Sockets and accessories 94.04 Approvals (according to type): Certain relay/socket combinations 094.91.3 86 SERIES Screw terminal (Box clamp) socket panel or 35 mm (EN 60715) rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 6-way jumper link Identification tag Marker tag holder Timer modules (see table below) Sheet of marker tags for plastic retaining and release clip 094.91.3 and for marker tag holder 097.00 , 48 tags, 6 x 12 mm for CEMBRE's thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Screw torque Wire strip length Max. wire size for 94.02/03/04 sockets 060.48 94.02 Blue 55.32 94.02.0 94.03 Black Blue 55.33 94.03.0 94.04 94.04.0 Black Blue Black 55.32, 55.34 094.71 094.91.3 094.91.30 094.91.3 094.91.30 094.91.3 094.91.30 094.06 094.06.0 094.06 094.06.0 094.06 094.06.0 094.00.4 097.00 86.30 060.48 10 A - 250 V 2 kV AC IP 20 -40...+70 Nm 0.5 mm 8 solid wire mm2 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 stranded wire 1 x 4 / 2 x 2.5 1 x 12 / 2 x 14 Top terminals R 94.04 OP EAN EU N T T E P A H Bottom terminals 094.06 (blue) 10 A - 250 V 86 series timer modules (12...24)V AC/DC; Bi-function: AI, DI; (0.05 s...100 h) (110...125)V AC; Bi-function: AI, DI; (0.05 s...100 h) (230...240)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 094.06.0 (black) EUR 6-way jumper link for 94.02, 94.03 and 94.04 sockets Rated values OP EAN 094.06 Approvals (according to type): X-2016, www.findernet.com 86.30 7 86 SERIES 86 SERIES Sockets and accessories Push-in terminals socket panel or 35 mm rail mount 95.P3 95.P5 For relay type 40.31 40.51/ 52/ 61, 44.52/62 Accessories Metal retaining clip 095.71 Plastic retaining and release clip (supplied with socket - packaging code SPA) 095.91.3 8-way jumper link 097.58 95.P5 2-way jumper link (12.5 mm pitch) 097.52 2-way jumper link (4.6 mm pitch) 097.42 Approvals Marker tag holder (for tags 060.48 and 060.72 types) 097.00 (according to type): Timer modules (see table below) 86.30 Identification tag 095.00.4 pending pending Sheet of marker tags for plastic retaining and release clip 095.91.3 and for marker tag holder 097.00, 48 tags, 6 x 12 mm, for CEMBRE's thermal transfert printer 060.48 Technical data Rated values 10 A - 250 V* 095.91.3 Dielectric strength 6 kV (1.2/50 s) between coil and contacts Protection category IP 20 Ambient temperature C -40...+70 (see diagram L95) Wire strip length mm 8 Min. wire size for 95.P3 and 95.P5 sockets solid wire stranded wire mm2 0.5 0.5 AWG 21 21 060.48 Max. wire size for 95.P3 and 95.P5 sockets solid wire stranded wire mm2 2 x 1.5 / 1 x 2.5 2 x 1.5 / 1 x 2.5 AWG 2 x 18 / 1 x 14 2 x 18 / 1 x 14 * For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. L 95 - Total socket current vs ambient temperature Total socket current (A) 11 A2 H COM 14 NO 12 NC A1 COIL 95.P3 95.P3 8-way jumper link for 95.P3 and 95.P5 sockets Rated values 95.P5 95.P5 097.58 10 A - 250 V 097.58 2-way jumper link for 95.P3 and 95.P5 sockets Rated values 097.52 10 A - 250 V 2-way jumper link for 95.P3 and 95.P5 sockets Rated values 097.42 10 A - 250 V Marker tag holder for 95.P3 and 95.P5 sockets 097.00 86 series timer modules (12...24)V AC/DC; Bi-function: AI, DI; (0.05 s...100 h) (110...125)V AC; Bi-function: AI, DI; (0.05 s...100 h) (230...240)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 097.52 097.00 86.30 8 Approvals (according to type): X-2016, www.findernet.com 097.42 86 SERIES Sockets and accessories 95.05 Approvals (according to type): ertain relay/socket C combinations 095.01 86 SERIES Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 8-way jumper link Marker tag holder (for tags 060.48 and 060.72 types) Identification tag Timer modules (see table below) Sheet of marker tags for plastic retaining and release clip 095.01 and for marker tag holder 097.00, 48 tags, 6 x 12 mm, for CEMBRE's thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Screw torque 95.03.0 (black) 95.05 (blue) 95.05.0 (black) 40.51, 40.52, 40.61 095.71 095.01 095.18 095.01.0 095.18.0 095.01 095.18 097.00 095.00.4 86.30 095.01.0 095.18.0 060.48 10 A - 250 V* 6 kV (1.2/50 s) between coil and contacts IP 20 -40...+70 (see diagram L95) Nm 0.5 Wire strip length Max. wire size for 95.03 and 95.05 sockets 060.48 95.03 (blue) 40.31 mm 8 solid wire mm2 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 stranded wire 1 x 4 / 2 x 2.5 1 x 12 / 2 x 14 * For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). Total socket current (A) L 95 - Total socket current vs ambient temperature 11 A2 COM 14 NO 12 NC A1 COIL P A PEAN N T E O O T 95.03 H 95.05 8-way jumper link for 95.03 and 95.05 sockets Rated values 095.18 (blue) 10 A - 250 V 86 series timer modules (12...24)V AC/DC; Bi-function: AI, DI; (0.05 s...100 h) (110...125)V AC; Bi-function: AI, DI; (0.05 s...100 h) (230...240)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 095.18.0 (black) EUR EUR 95.03 PEAN 095.18 Approvals (according to type): X-2016, www.findernet.com 86.30 9 86 SERIES 86 SERIES Sockets and accessories Screw terminal (Box clamp) socket panel or 35 mm rail (EN 60715) mount For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Plastic retaining and release clip (supplied with socket - packaging code SPA) 6-way jumper link Identification tag Timer modules Technical data Rated values Dielectric strength Protection category Ambient temperature 96.02 Approvals (according to type): 96.04 Approvals (according to type): Screw torque 96.02 Blue 56.32 96.02.0 Black 094.71 96.04 Blue 56.34 96.04.0 Black 096.71 094.91.3 094.06 095.00.4 86.30 094.91.30 094.06.0 -- -- 090.00.2 86.00, 86.30 -- -- 12 A - 250 V 2 kV AC IP 20 C -40...+70 Nm 0.8 Wire strip length Max. wire size for 96.02/04 sockets mm 8 solid wire mm2 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 stranded wire 1 x 4 / 2 x 2.5 1 x 12 / 2 x 14 094.91.3 H P A PEAN N T E O O T EUR EUR 96.02 96.02 + 56.32 + 094.91.3 + 86.30 96.04 96.04 + 56.34 + 096.71 + 86.00 6-way jumper link for 96.02 socket 094.06 (blue) Rated values 10 A - 250 V 094.06.0 (black) PEAN X-2016, www.findernet.com 094.06 10 86 SERIES Sockets and accessories 97.P2 Approvals (according to type): 097.01 060.48 86 SERIES Push-in terminal socket panel or 35 mm rail (EN 60715) mount For relay type Accessories Plastic retaining and release clip (supplied with socket - packaging code SPA) Metal retaining clip Identification tag 8-way jumper link 2-way jumper link 2-way jumper link Marker tag holder Timer modules (see table below) Sheet of marker tags for marker tag holder 097.00, 48 tags, 6 x 12 mm, for CEMBRE's thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Wire strip length mm Min. wire size for 97.P1 and 97.P2 socket mm2 AWG Max. wire size for 97.P1 and 97.P2 socket mm2 AWG 97.P1 46.61 97.P2 46.52 097.01 097.71 095.00.4 097.58 097.52 097.42 097.00 86.30 060.48 16 A-250 V AC 8 A-250 V AC 6 kV (1.2/50 s) between coil and contacts IP 20 -40...+70 (see diagram L97) 8 solid wire stranded wire 0.5 0.5 21 21 solid wire stranded wire 2 x 1.5 / 1 x 2.5 2 x 1.5 / 1 x 2.5 2 x 18 / 1 x 14 2 x 18 / 1 x 14 Rated current (A) L 97 - Rated current vs ambient temperature 97.P1 H 97.P2 8-way jumper link for 97.P1 and 97.P2 sockets Rated values 097.58 10 A - 250 V 2-way jumper link for 97.P1 and 97.P2 sockets Rated values 097.52 10 A - 250 V 2-way jumper link for 97.P1 and 97.P2 sockets Rated values 097.42 10 A - 250 V Marker tag holder for 95.P3 and 95.P5 sockets 097.00 86 series timer modules (12...24)V AC/DC; Bi-function: AI, DI; (0.05 s...100 h) (110...125)V AC; Bi-function: AI, DI; (0.05 s...100 h) (230...240)V AC; Bi-function: AI, DI; (0.05 s...100 h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 097.58 097.52 X-2016, www.findernet.com 097.42 097.00 86.30 Approvals (according to type): 11 86 SERIES 86 SERIES Sockets and accessories Screw terminal socket panel or 35 mm rail (EN 60715) mount For relay type Accessories Plastic retain and eject clip (supplied with socket - packaging code SPA) 8-way jumper link Identification tag Timer modules Technical data Rated current Dielectric strength Protection category Ambient temperature 97.01 Approvals (according to type): Screw torque 97.02 Blue 46.52 097.01 095.18 (blue) 095.00.4 86.30 095.18.0 (black) 16 A - 250 V AC 8 A - 250 V AC 6 kV (1.2/50 s) between coil and contacts IP 20 C -40...+70 (see diagram L97) Nm 0.8 Wire strip length Max. wire size for 97.01 and 97.02 sockets 097.01 97.01 Blue 46.61 mm 8 solid wire mm2 1 x 6 / 2 x 2.5 AWG 1 x 10 / 2 x 14 stranded wire 1 x 4 / 2 x 2.5 1 x 12 / 2 x 14 L 97 - Rated current vs ambient temperature (for 46.61 relay / 97.01 socket combination) Rated current (A) H 97.01 97.01 97.02 97.02 P A PEAN N T E O O T EUR EUR 97.02 + 46.52 + 097.01 + 86.30 8-way jumper link for 97.01 and 97.02 sockets 095.18 (blue) Rated values 10 A - 250 V 095.18.0 (black) PEAN X-2016, www.findernet.com 095.18 12