Timer modules for use in conjunction with
relay & socket.
86.00 - Multi-function & multi-voltage timer
module
86.30 - Bi-function & multi-voltage timer module
Timer module type 86.00 for 90, 92, 96
series sockets and type 86.30 for 90, 92, 94, 95,
96, 97 series sockets
Wide supply voltage range:
12…240VAC/DC (86.00)
12…24VAC/DC or 230…240VAC (86.30)
LED indicator
86.00
86.30
86.00 86.30
Time scale: from 0.05s to 100h
Multi-function
Plug-in for use with 90.02, 90.03, 92.03 and
96.04 sockets
Time scale: from 0.05s to 100h
Bi-function
Plug-in for use with 90.02, 90.03, 92.03, 94.P3,
94.P4, 94.02, 94.03, 94.04, 95.P3, 95.P5, 95.03,
95.05, 96.02, 96.04, 97.P1, 97.P2, 97.01 and
97.02 sockets
AI: On-delay
DI: Interval
SW: Symmetrical flasher (starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
EE: Interval with control signal off
FE: Interval with control signal on and off
AI: On-delay
DI: Interval
Relay + socket
Wiring diagram
(without control signal)
Relay + socket
Wiring diagram
(with control signal)
Relay + socket
Wiring diagram
Contact specification
Contact configuration
See 56, 60 and 62 series relays
Note: Do not use with relays
62.3x.x012.x300 and 62.3x.x012.x600
See 40, 44, 46, 55, 56, 60 and
62 series relays
Rated current/Maximum peak current A
Rated voltage/
Maximum switching voltage VAC
Rated load AC1 VA
Rated load AC15 (230VAC) VA
Single phase motor rating (230VAC) kW
Breaking capacity DC1: 30/110/220V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (UN) VAC (50/60Hz) 12…240 12…24 110…125 230…240
VDC 12…240 12…24
Rated power AC/DC W 1.2 0.15
Operating range VAC (50/60Hz) 10.2…265 9.6…33.6 88…137 184…265
DC 10.2…265 9.6…33.6
Technical data
Specified time range (0.05…1)s, (0.5…10)s, (5…100)s, (0.5…10)min, (5…100)min, (0.5…10)h, (5…100)h
Repeatability % ±1 ±1
Recovery time ms ≤50 ≤50
Minimun control impulse ms 50
Setting accuracy full range % ±5 ±5
Electrical life at rated load in AC1 cycles See 56, 60 and 62 series relays See 40, 44, 46, 55, 56, 60 and 62 series relays
Ambient temperature range °C –20…+50 –20…+50
Protection category IP 20 IP 20
Approvals (according to type)
1
X-2016, www.findernet.com
H
86
SERIES
86 SERIES
Timer modules
Ordering information
Example: 86 series multi-function timer module, (12…240)VAC/DC supply voltage.
8 6 . 0 0 . 0 . 2 4 0 . 0 0 0 0
Series
Type
0 = Multi-function (AI, DI, SW, BE, CE, DE, EE, FE)
3 = Bi-function (AI, DI)
No. of poles
See 40, 44, 46, 55, 56, 60 and 62series relays
Poles for chosen relay/socket combination -
according to chart below
Supply voltage
024 = (12…24)VAC/DC (86.30 only)
120 = (110…125)VAC (86.30 only)
240 = (12…240)VAC/DC (86.00 only)
240 = (230…240)VAC (86.30 only)
Supply version
0 = AC (50/60Hz)/DC
8 = AC (50/60Hz)
Combinations Number of poles Relay type Socket type Timer module
1 40.31 95.P3/95.03 86.30
1 40.61 95.P5/95.05 86.30
1 46.61 97.P1/97.01 86.30
2 40.52/44.52/44.62 95.P5/95.05 86.30
2 46.52 97.P2/97.02 86.30
2 55.32 94.P4/94.02 86.30
2 56.32 96.02 86.30
2 60.12 90.02 86.00/86.30
2 62.32 92.03 86.00/86.30
3 55.33 94.P3/94.03 86.30
3 60.13 90.03 86.00/86.30
3 62.33 92.03 86.00/86.30
4 55.34 94.P4/94.04 86.30
4 56.34 96.04 86.00/86.30
Technical data
EMC specifications
Type of test Reference standard 86.00 86.30
Electrostatic discharge contact discharge EN61000-4-2 4kV n.a.
air discharge EN61000-4-2 8kV 8kV
Radio-frequency electromagnetic field (80÷1000MHz) EN61000-4-3 10V/m 10V/m
Fast transients (burst) (5-50 ns, 5kHz) on Supply terminals EN61000-4-4 4kV 2kV
Surges (1.2/50µs) on Supply terminals common mode EN61000-4-5 4kV 2kV
differential mode EN61000-4-5 4kV 1kV
Radio-frequency common mode (0.15÷80MHz)
on Supply terminals EN61000-4-6 10V 10V
Radiated and conducted emission EN 55022 class B class B
Other data 86.00 86.30
Current absorption on signal control (B1)
mA 1
Power lost to the environment without contact current W 0.1 (12V) - 1 (230V) 0.2
with rated current See 56, 60 and 62 series relays See 40, 44, 46, 55, 56, 60, 62 series
relays
Times scales
NOTE: Time scales and functions must be set before energising the timer.
To achieve the minimum time setting of 0.05seconds it is necessary to use one of the functions with control signal.
When setting very short times it may be necessary to take into account the operate time of the relay used.
2
X-2016, www.findernet.com
H
86 SERIES
Timer modules
86
SERIES
Functions
U = Supply voltage
S = Signal switch
= Output contact
LED
Type 86.00
LED
Type 86.30
Supply
voltage
NO output
contact
OFF Open
ON Open
ON Open
(Timing in Progress)
ON Closed
Without control signal = Start via contact in supply line (A1).
With control signal = Start via contact into control terminal (B1).
Wiring diagram Type 86.00
Without control signal (AI) On-delay.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
(DI) Interval.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(SW) Symmetrical flasher (starting pulse on).
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is
applied. The ratio is 1:1 (time on= time off).
With control signal
*
* With DC supply,
positive polarity has
to be conneted to B1
terminal (according to
EN60204-1).
Switch S should be
exclusively used to
provide the control
signal to terminal B1.
(Do not connect any
other load at this point).
(BE) Off-delay with control signal.
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the
Signal Switch (S). Opening the Signal Switch initiates the preset
delay, after which time the output contacts reset.
(CE) On- and off-delay with control signal.
Power is permenently applied to the timer.
Closing the Signal Switch (S) initiates the preset delay, after
which
time the output contacts transfer. Opening the Signal
switch initiates the same preset delay, after which time the
output contacts reset.
(DE) Interval with control signal on.
Power is permenently applied to the timer.
On momentary or maintained closure of Signal Switch (S),
the output contacts transfer, and remain so for the duration
of the preset delay, after which they reset.
(EE) Interval with control signal off.
Power is permenently applied to the timer.
On opening of the Signal Switch (S) the output contacts
transfer, and remain so for the duration of the preset delay,
after which they reset.
(FE) Interval with control signal on and off.
Power is permenently applied to the timer.
Both the opening and closing of the Signal Switch (S)
initiates the transfer of the output contacts. In both instances
the contacts reset after the delay period has elapsed.
Wiring diagram Type 86.30
(AI) On-delay.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
(DI) Interval.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
3
X-2016, www.findernet.com
H
86
SERIES
86 SERIES
Timer modules
90.03
Approvals
(according to type):
Screw terminal (Box clamp) socket
panel or 35mm rail (EN60715) mount
90.02
Blue
90.02.0
Black
90.03
Blue
90.03.0
Black
For relay type 60.12 60.13
Accessories
Metal retaining clip 090.33
6-way jumper link 090.06
Identification tag 090.00.2
Timer module 86.00, 86.30
Technical data
Double terminal A1 (for easy start connection)
Rated values 10A - 250V
Dielectric strength 2kVAC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.6
Wire strip length mm 10
Max. wire size for 90.02 and 90.03 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
90.02
90.02
90.03
77.5
3.2
38
35.5
21.6
420.4
33.5
26.9
81.1
30.5
34.8
90.03 90.03 + 60.13 + 86.00
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
090.06
Approvals
(according to type):
6-way jumper link for 90.02 and 90.03 sockets 090.06
Rated values 10A - 250V
4
X-2016, www.findernet.com
H
86 SERIES
Sockets and accessories
86
SERIES
92.03
Approvals
(according to type):
Screw terminal (Box clamp) socket
panel or 35mm rail (EN60715) mount
92.03
Blue
92.03.0
Black
For relay type 62.32, 62.33
Accessories
Metal retaining clip
(supplied with socket - packaging code SMA) 092.71
Identification tag 092.00.2
Timer modules 86.00, 86.30
Technical data
Rated values 16A - 250V
Dielectric strength 6kV (1.2/50µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70 (see diagram L92)
Screw torque Nm 0.8
Wire strip length mm 10
Max. wire size for 92.03 socket solid wire stranded wire
mm21x10 / 2x4 1x6 / 2x4
AWG 1x8 / 2x12 1x10 / 2x12
L 92 - Rated current vs ambient temperature
Rated current (A)
40
27
91.3
46.3
3.2
60.9
30.3
27
35.5
32
35.4 34.321.6
78.5
92.03 + 62.33 + 86.30
5
X-2016, www.findernet.com
H
86
SERIES
86 SERIES
Sockets and accessories
94.P4
Approvals
(according to type):
Certain relay/socket
combinations
094.91.3
060.48
Push-in terminal socket panel or 35mm
(EN60715) rail mount
94.P3
Blue
94.P4
Blue
For relay type 55.33 55.32, 55.34
Accessories
Metal retaining clip 094.71
Plastic retaining and release clip
(supplied with socket - packaging code SPA) 094.91.3
6-way jumper link 094.56
Identification tag 094.00.4
2-way jumper link 094.52.1
2-way jumper link 097.52
Marker tag holder 097.00
Timer modules (see table below) 86.30
Sheet of marker tags for plastic retaining and release clip
094.91.3 and for marker tag holder 097.00 , 48 tags, 6x12mm
for CEMBRE's thermal transfer printers 060.48
Technical data
Rated values 10A - 250V
Dielectric strength 2kVAC
Protection category IP 20
Ambient temperature °C –40…+70
Wire strip length mm 8
Min. wire size for 94.P3 and 94.P4 sockets solid wire stranded wire
mm20.5 0.5
AWG 21 21
Max. wire size for 94.P3 and 94.P4 sockets solid wire stranded wire
mm22x1.5 / 1x2.5 2x1.5 / 1x2.5
AWG 2x18 / 1x14 2x18 / 1x14
94.P4
94.P3
094.56
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
6-way jumper link for 94.P3 and 94.P4 sockets 094.56 (blue)
Rated values 10A - 250V
094.52.1
2-way jumper link for 94.P3 and 94.P4 sockets 094.52.1
Rated values 10A - 250V
097.52
2-way jumper link for 94.P3 and 94.P4 sockets 097.52
Rated values 10A - 250V
097.00
Marker tag holder for 94.P3 and 94.P4 sockets 097.00
86.30
86 series timer modules
(12…24)VAC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000
(110…125)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000
(230…240)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000
Approvals (according to type):
6
X-2016, www.findernet.com
H
86 SERIES
Sockets and accessories
86
SERIES
94.04
Approvals
(according to type):
Certain relay/socket
combinations
094.91.3
060.48
Screw terminal (Box clamp) socket panel or 35mm
(EN60715) rail mount
94.02
Blue
94.02.0
Black
94.03
Blue
94.03.0
Black
94.04
Blue
94.04.0
Black
For relay type 55.32 55.33 55.32, 55.34
Accessories
Metal retaining clip 094.71
Plastic retaining and release clip
(supplied with socket - packaging code SPA) 094.91.3
094.91.30
094.91.3
094.91.30
094.91.3
094.91.30
6-way jumper link 094.06 094.06.0 094.06 094.06.0 094.06 094.06.0
Identification tag 094.00.4
Marker tag holder 097.00
Timer modules (see table below) 86.30
Sheet of marker tags for plastic retaining and release clip
094.91.3 and for marker tag holder 097.00 , 48 tags, 6x12mm
for CEMBRE's thermal transfer printers 060.48
Technical data
Rated values 10A - 250V
Dielectric strength 2kVAC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 8
Max. wire size for 94.02/03/04 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
94.04
Top
terminals
Bottom
terminals
094.06
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
6-way jumper link for 94.02, 94.03 and 94.04 sockets 094.06 (blue) 094.06.0 (black)
Rated values 10A - 250V
86.30
86 series timer modules
(12…24)VAC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000
(110…125)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000
(230…240)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000
Approvals (according to type):
7
X-2016, www.findernet.com
H
86
SERIES
86 SERIES
Sockets and accessories
95.P5
Approvals
(according to type):
pending pending
095.91.3
060.48
Push-in terminals socket panel or 35mm rail mount 95.P3 95.P5
For relay type 40.31 40.51/ 52/ 61, 44.52/62
Accessories
Metal retaining clip
095.71
Plastic retaining and release clip
(supplied with socket - packaging code SPA)
095.91.3
8-way jumper link 097.58
2-way jumper link (12.5
mm pitch) 097.52
2-way jumper link (4.6
mm pitch) 097.42
Marker tag holder (for tags 060.48 and 060.72 types) 097.00
Timer modules (see table below) 86.30
Identification tag 095.00.4
Sheet of marker tags for plastic retaining and release clip
095.91.3 and for marker tag holder 097.00, 48 tags,
6x12mm, for CEMBRE's thermal transfert printer 060.48
Technical data
Rated values
10A - 250V*
Dielectric strength 6kV (1.2/50µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70 (see diagram L95)
Wire strip length mm 8
Min. wire size for 95.P3 and 95.P5 sockets solid wire stranded wire
mm20.5 0.5
AWG 21 21
Max. wire size for 95.P3 and 95.P5 sockets solid wire stranded wire
mm22x1.5 / 1x2.5 2x1.5 / 1x2.5
AWG 2x18 / 1x14 2x18 / 1x14
* For currents >10A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).
With the relay 40.51 the change-over contact will be 21-12-14.
L 95 - Total socket current vs ambient temperature
A2 A1 COIL
11 COM
NO
NC
14
12
95.P3
95.P5
95.P3 95.P5
Total socket current (A)
097.58
8-way jumper link for 95.P3 and 95.P5 sockets 097.58
Rated values 10A - 250V
097.52
2-way jumper link for 95.P3 and 95.P5 sockets 097.52
Rated values 10A - 250V
097.42
2-way jumper link for 95.P3 and 95.P5 sockets 097.42
Rated values 10A - 250V
097.00
Marker tag holder for 95.P3 and 95.P5 sockets 097.00
86.30
86 series timer modules
(12…24)VAC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000
(110…125)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000
(230…240)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000
Approvals (according to type):
8
X-2016, www.findernet.com
H
86 SERIES
Sockets and accessories
86
SERIES
95.05
Approvals
(according to type):
Certain relay/socket
combinations
095.01
060.48
Screw terminal (Box clamp) socket panel or 35mm rail mount 95.03 (blue) 95.03.0 (black) 95.05 (blue) 95.05.0 (black)
For relay type 40.31 40.51, 40.52, 40.61
Accessories
Metal retaining clip
095.71
Plastic retaining and release clip
(supplied with socket - packaging code SPA)
095.01 095.01.0 095.01 095.01.0
8-way jumper link 095.18 095.18.0 095.18 095.18.0
Marker tag holder (for tags 060.48 and 060.72 types) 097.00
Identification tag 095.00.4
Timer modules (see table below) 86.30
Sheet of marker tags for plastic retaining and release clip
095.01 and for marker tag holder 097.00, 48 tags, 6
x
12
mm,
for CEMBRE’s thermal transfer printers 060.48
Technical data
Rated values
10A - 250V*
Dielectric strength 6kV (1.2/50µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70 (see diagram L95)
Screw torque Nm 0.5
Wire strip length mm 8
Max. wire size for 95.03 and 95.05 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
* For currents >10A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).
L 95 - Total socket current vs ambient temperature
A2 A1 COIL
11 COM
NO
NC
14
12
95.03
95.03 95.05
Total socket current (A)
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
095.18
8-way jumper link for 95.03 and 95.05 sockets 095.18 (blue) 095.18.0 (black)
Rated values 10A - 250V
86.30
86 series timer modules
(12…24)VAC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000
(110…125)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000
(230…240)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000
Approvals (according to type):
9
X-2016, www.findernet.com
H
86
SERIES
86 SERIES
Sockets and accessories
96.02
Approvals
(according to type):
96.04
Approvals
(according to type):
094.91.3
Screw terminal (Box clamp) socket
panel or 35mm rail (EN60715) mount
96.02
Blue
96.02.0
Black
96.04
Blue
96.04.0
Black
For relay type 56.32 56.34
Accessories
Metal retaining clip
(supplied with socket - packaging code SMA)
094.71 096.71
Plastic retaining and release clip
(supplied with socket - packaging code SPA) 094.91.3 094.91.30
6-way jumper link 094.06 094.06.0
Identification tag 095.00.4 090.00.2
Timer modules 86.30 86.00, 86.30
Technical data
Rated values 12A - 250V
Dielectric strength 2kVAC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.8
Wire strip length mm 8
Max. wire size for 96.02/04 sockets solid wire
stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
96.02 96.02 + 56.32 + 094.91.3 + 86.30 96.04 96.04 + 56.34 + 096.71 + 86.00
094.06
6-way jumper link for 96.02 socket 094.06 (blue) 094.06.0 (black)
Rated values 10A - 250V
10
X-2016, www.findernet.com
H
86 SERIES
Sockets and accessories
86
SERIES
97.P2
Approvals
(according to type):
097.01
060.48
Push-in terminal socket panel or 35mm rail (EN60715) mount 97.P1 97.P2
For relay type 46.61 46.52
Accessories
Plastic retaining and release clip
(supplied with socket - packaging code SPA) 097.01
Metal retaining clip 097.71
Identification tag 095.00.4
8-way jumper link 097.58
2-way jumper link 097.52
2-way jumper link 097.42
Marker tag holder 097.00
Timer modules (see table below) 86.30
Sheet of marker tags for marker tag holder 097.00, 48 tags,
6x12 mm, for CEMBRE’s thermal transfer printers 060.48
Technical data
Rated values 16A-250VAC 8A-250VAC
Dielectric strength 6kV (1.2/50μs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70 (see diagram L97)
Wire strip length mm 8
Min. wire size for 97.P1 and 97.P2 socket solid wire stranded wire
mm20.5 0.5
AWG 21 21
Max. wire size for 97.P1 and 97.P2 socket solid wire stranded wire
mm22x1.5 / 1x2.5 2x1.5 / 1x2.5
AWG 2x18 / 1x14 2x18 / 1x14
L 97 - Rated current vs ambient temperature
97.P1 97.P2
Rated current (A)
097.58
8-way jumper link for 97.P1 and 97.P2 sockets 097.58
Rated values 10A - 250V
097.52
2-way jumper link for 97.P1 and 97.P2 sockets 097.52
Rated values 10A - 250V
097.42
2-way jumper link for 97.P1 and 97.P2 sockets 097.42
Rated values 10A - 250V
097.00
Marker tag holder for 95.P3 and 95.P5 sockets 097.00
86.30
86 series timer modules
(12…24)VAC/DC; Bi-function: AI, DI; (0.05s…100h) 86.30.0.024.0000
(110…125)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000
(230…240)VAC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.240.0000
Approvals (according to type):
11
X-2016, www.findernet.com
H
86
SERIES
86 SERIES
Sockets and accessories
97.01
Approvals
(according to type):
097.01
Screw terminal socket
panel or 35mm rail (EN60715) mount
97.01
Blue
97.02
Blue
For relay type 46.61 46.52
Accessories
Plastic retain and eject clip
(supplied with socket - packaging code SPA) 097.01
8-way jumper link 095.18 (blue) 095.18.0 (black)
Identification tag 095.00.4
Timer modules 86.30
Technical data
Rated current
16A - 250VAC 8A - 250VAC
Dielectric strength 6kV (1.2/50µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70 (see diagram L97)
Screw torque Nm 0.8
Wire strip length mm 8
Max. wire size for 97.01 and 97.02 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
L 97 - Rated current vs ambient temperature
(for 46.61 relay / 97.01 socket combination)
Rated current (A)
97.01 97.01 97.02 97.02
   




97.02 + 46.52 + 097.01
+ 86.30
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
095.18
8-way jumper link for 97.01 and 97.02 sockets 095.18 (blue) 095.18.0 (black)
Rated values 10A - 250V
12
X-2016, www.findernet.com
H
86 SERIES
Sockets and accessories
86
SERIES