SERIES ESTABLISHED RELIABILITY ESTABLISHED RELIABILITY TO-5 RELAYS 412 DPDT SERIES DESIGNATION RELAY TYPE 412 DPDT basic relay 412D DPDT relay with internal diode for coil suppression DPDT relay with internal diodes for coil transient suppression and polarity reversal protection 412DD DPDT relay with internal transistor driver and coil transient suppression diode 412T INTERNAL CONSTRUCTION UNI-FRAME DESCRIPTION UPPER STATIONARY CONTACT ARMATURE LOWER STATIONARY CONTACT MOVING CONTACT ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS Temperature (Ambient) -65C to +125C Vibration (General Note 1) 30 g's to 3000 Hz Shock (General Note 1) 75 g's, 6 msec, half-sine Acceleration 50 g's Enclosure Hermetically sealed Weight 0.09 oz. (2.55g) max. (c)2003 TELEDYNE RELAYS The TO-5 relay, originally conceived and developed by Teledyne, has become one of the industry standards for low-level switching from dry circuit to 1 ampere. Designed expressly for high-density PC board mounting, its small size and low coil power dissipation make the 412 relay one of the most versatile ultraminiature relays available. The following unique construction features and manufacturing techniques provide excellent resistance to environmental extremes and overall high reliability. * All welded construction. * Unique uni-frame design, providing high magnetic efficiency and mechanical rigidity. * High force/mass ratios for resistance to shock and vibration. * Advanced cleaning techniques provide maximum assurance of internal cleanliness. * Precious metal alloy contact material with gold plating assures excellent high current and dry circuit switching capabilities. The Series 412D and 412DD relays have internal discrete silicon diodes for coil suppression and polarity reversal protection. The hybrid 412T relay features an internal silicon suppression diode and transistor driver. This hybrid package reduces required PC board floor space by reducing the number of external components needed to drive the relay. By virtue of its inherently low intercontact capacitance and contact circuit losses, the 412 relay has proven to be an excellent ultraminiature RF switch for frequency ranges well into the UHF spectrum. A typical RF application for the TO-5 relay is in handheld radio transceivers, wherein the combined features of good RF performance, small size, low coil power dissipation and high reliability make it a preferred method of T-R switching (see Figure 1). SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE www.teledynerelays.com 412 Page 1 412/1203/Q1 SERIES 412 GENERAL ELECTRICAL SPECIFICATIONS (-65C to +125C unless otherwise noted) (Notes 2 & 3) Contact Arrangement Rated Duty Contact Resistance 2 Form C (DPDT) Continuous 0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header) Contact Load Ratings (DC) (See Fig. 2 for other DC resistive voltage/current ratings) Resistive: Inductive: Lamp: Low Level: 1 Amp/28Vdc 200 mA/28Vdc (320 mH) 100 mA/28Vdc 10 to 50 A/10 to 50mV Resistive: 250 mA/115Vac, 60 and 400 Hz (Case not grounded) 100 mA/115Vac, 60 and 400 Hz (Case grounded) Contact Load Ratings (AC) ESTABLISHED RELIABILITY 10,000,000 cycles (typical) at low level 1,000,000 cycles (typical) at 0.5A/28Vdc resistive 100,000 cycles min. at all other loads specified above Contact Life Ratings Contact Overload Rating 2A/28Vdc Resistive (100 cycles min.) Contact Carry Rating Contact factory Coil Operating Power 450 milliwatts typical at nominal rated voltage @ 25C Operate Time 2.0 msec max. at nominal rated coil voltage Release Time 412 Series: 1.5 msec max. 412D, 412DD Series: 4.0 msec max. 412T Series: 7.5 msec max. Contact Bounce 1.5 msec max. Intercontact Capacitance 0.4 pf typical Insulation Resistance 10,000 megohms min. between mutually isolated terminals Dielectric Strength Atmospheric pressure: 500 Vrms/60Hz 70,000 ft.: 125 Vrms/60Hz Negative Coil Transient (Vdc) 412D, 412DD, 412T 1.0 max Diode P.I.V. (Vdc) 412D, 412DD, 412T 100 min. Base Turn Off Voltage (Vdc) 0.3 min. 412T Transistor Emitter-base breakdown Voltage (BVEBO) (@25C) (Vdc) 6.0 min. Characteristics Collector-base breakdown Voltage (BVEBO) (@25C & lc = 100 A) (Vdc) 75 min. DETAILED ELECTRICAL SPECIFICATIONS (-65C to +125C unless otherwise noted) (Note 3) 412-5 412D-5 412DD-5 412T-5 5.0 5.8 50 39 93.2 128.2 82.2 112.1 3.5 3.9 3.5 3.00 0.14 2.3 0.6 2.8 BASE PART NUMBERS (See Note 10 for full P/N example) Nom. Max. 412, 412D, 412T (Note 4) Coil Resistance (Ohms 10% @25C) 412DD (Note 4) Min. Coil Current (mAdc @25C) (412DD Series) Max. Min. Coil Current (mAdc @25C) (Note 7) (412T Series) Max. 412, 412D Pick-up Voltage (Vdc, Max.) 412DD 412T (Note 7) Base Current to Turn On (mAdc, Max.) (412T Series) (Note 7) Min. 412, 412D, 412T Max. Drop-out Voltage (Vdc) Min. 412DD Max. Coil Voltage (Vdc) 412-6 412D-6 412DD-6 412T-6 6.0 8.0 98 78 58.3 78.3 52.9 69.9 4.5 5.2 4.5 2.04 0.18 3.2 0.7 3.4 412-9 412D-9 412DD-9 412T-9 9.0 12.0 220 220 33.0 42.9 35.3 47.4 6.8 7.8 6.8 1.36 0.35 4.9 0.8 5.3 PERFORMANCE CURVES TYPICAL RF PERFORMANCE (NOTE 2) 0 ER TIO OS 10 1.92 ) WR SS (VS 1.22 N LO RETUR 30 CTS 1.07 NTA 40 N ATIO CO OSS ACR ISOL 50 TION OLA OSS ACR LES 1.02 PO 1.01 IS 60 250 200 150 100 50 1.00 70 1.00 .01 FIGURE 1 412 Page 2 VSWR dB .4 LOAD VOLTAGE (VDC) S .3 20 412-26 412D-26 412DD-26 412T-26 26.5 32.0 1560 1560 14.8 18.5 14.7 19.8 18.0 19.0 18.0 0.50 0.89 13.0 1.4 13.0 300 NL .2 412-18 412D-18 412DD-18 412T-18 18.0 24.0 880 880 17.5 22.1 17.9 24.0 13.5 14.5 13.5 0.68 0.59 10.0 1.1 10.0 TYPICAL DC CONTACT RATING (RESISTIVE) INS .1 412-12 412D-12 412DD-12 412T-12 12.0 16.0 390 390 25.6 32.8 26.6 35.8 9.0 10.0 9.0 1.03 0.41 6.5 0.9 6.5 0.5 .1 FREQUENCY (GHz) .5 1.0 0 FIGURE 2 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOAD CURRENT (AMPS DC) SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE www.teledynerelays.com (c)2003 TELEDYNE RELAYS 412/1203/Q1 SERIES 412 OUTLINE DIMENSIONS SCHEMATIC DIAGRAMS TERMINAL LOCATIONS AND PIN NUMBERING (REF. ONLY) (Viewed from Terminals) .370 (9.40) DIA. MAX. .031 (.79) .003 (0.08) .335 (8.51) DIA. MAX. 10 TRANSISTOR BASE CONNECTION FOR 412T ONLY .035 (.89) .010 (0.25) 9 412 412DD 412D 412T 1 8 2 7 3 .270 (6.86) MAX. ESTABLISHED RELIABILITY WIRE LEAD: .75 (19.05) MIN. PIN: .187 (4.75) .010 (.25) (See Note 6) +.002 (.05) .017 (.43) -.001 (.03) DIA. 6 36 3 TYP. .200 (5.08) .010 (.25) DIA. 4 5 SCHEMATICS ARE VIEWED FROM TERMINALS DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS) TYPICAL LOGIC INTERFACE GENERAL NOTES (See Note 8) 1. Relay contacts will exhibit no chatter in excess of 10 sec or transfer in excess of 1 sec. 2. "Typical" characteristics are based on available data and are best estimates. No on-going verification tests are performed. 3. Unless otherwise specified, parameters are initial values. 4. For reference only. Coil resistance not directly measurable at relay terminals due to internal series semiconductor. 412DD and 412T only. 5. Unless otherwise specified, relays will be supplied with either gold-plated or solder-coated leads. 6. The slash and characters appearing after the slash are not marked on the relay. 7. Limit Base Emitter current to 15 mAdc. 8. Applicable to all coil voltages. See Base current to turn on. 9. Screened HI-REL versions available. Contact factory. 10. Vcc Vr Pin 1 Notes: Logic 1 activates the relay. Logic 0 de-activates the relay. Vcc = logic bias power. Vr = coil energization voltage. Logic element Pin 10 1 = 0.50 to 3.00mA 0 = 0.3Vdc min. Pin 9 Teledyne Part Numbering System for T2R(R) Established Reliability Relay ER 412 Y M - 26 A / S Q Established Reliability Designator Q= Solder-Coated Leads G= Gold-Plated Leads (Notes 5 and 6) S= .187" leads (Note 6) Relay Series Optional Ground Pin (See Appendix) Screening and Reliability Level Pad Option (See Appendix) Coil Voltage Teledyne Part Numbering System for Military Qualified (JAN) Relays J 412 Y M - 26 P L Military (JAN) Designator Screening and Reliability Level Relay Series Optional Ground Pin (See Appendix) Terminal Variant P = 0.187" Coil Voltage Spreader Option (See Appendix) (c)2003 TELEDYNE RELAYS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE www.teledynerelays.com 412 Page 3 412/1203/Q1 Appendix A: Spacer Pads Pad designation and bottom view dimensions Height O.150 [3.81] (REF) Dim H MAX "M4" Pad for TO-5 Dim H MAX "M4" Pad for TO-5 Dim H MAX "M4" Pad for Centigrid(R) .156 [3.96] (REF) Dim H MAX .256 [6.5] (REF) "M9" Pad for Centigrid(R) For use with the following: ER411T ER412, ER412D, ER412DD 712, 712D, 712TN, RF300, RF310, RF320 ER420, ER422D, ER420DD, 421, ER421D, ER421DD, ER422, ER422D, ER422DD, 722, 722D, RF341 ER431T, ER432T, ER432, ER432D, ER432DD 732, 732D, 732TN, RF303, RF313, RF323 .295 (7.49) .300 (7.62) .305 (7.75) .400 (10.16) .410 (10.41) RF312 .350 (8.89) ER411, ER411D, ER411DD .295 (7.49) ER431, ER431D, ER431DD .400 (10.16) RF311 .300 (7.62) RF331 .410 (10.41) 172, 172D .305 (7.75) ER114, ER114D, ER114DD, J114, J114D, J114DD .300 (7.62) ER134, ER134D, ER134DD, J134, J134D, J134DD .400 (10.16) RF100 .315 (8.00) RF103 .420 (10.67) 122C, A152 .320 (8.13) ER116C, J116C .300 (7.62) ER136C, J136C .400 (10.16) RF180 .325 (8.25) A150 .305 (7.75) Notes: 1. Spacer pad material: Polyester lm. 2. To specify an "M4" or "M9" spacer pad, refer to the mounting variants portion of the part numbering example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise specied, tolerance is .010 (.25). 5. Add 10 m to the contact resistance show in the datasheet. 6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. (c) 2008 Teledyne Relays Dim. H Max. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Appendix A: Spreader Pads Pad designation and bottom view dimensions Height For use with the following: .370 [9.4] MAX SQ .100 [2.54] Dim H MAX .150 [3.81] .014 [0.36] (REF) .300 [7.62] .100 [2.54] .370 [9.4] MIN .200 [5.08] "M" Pad 5/ 6/ .390 [9.91] SQ .100 [2.54] .100 [2.54] .150 [3.81] .300 [7.62] .300 [7.62] .150 [3.81] Dim H MAX ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD ER412T, J412T 712, 712D, 712TN ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD ER432T, J432T 732, 732D, 732TN .370 [9.4] MAX SQ .100 [2.54] Dim H MAX .150 [3.81] .014 [0.36] (REF) .300 [7.62] .100 [2.54] .200 [5.08] .370 [9.4] MIN "M3" Pad 5/ 6/ 9/ .393 (9.99) .493 (12.52) .503 (12.78) .398 (10.11) ER411T ER412, ER412D, ER412DD J412, J412D, J412DD .441 (11.20) 732, 732D "M2" Pad 7/ 8/ .388 (9.86) ER420, J420, ER420D, J420D ER420DD, J420DD, ER421, J421 ER421D, J421D, ER421DD J422D, ER422DD, J422DD, 722 712, 712D ER421, ER421D, ER421DD 722, 732D ER431T ER432, ER432D, ER432DD .130 [3.3] Dim. H Max. ER411, ER411D, ER411DD ER411TX ER412X, ER412DX, ER412DDX ER412TX 712X, 712DX, 712TNX ER420X, ER420DX, ER420DDX ER421X, ER421DX, ER421DDX ER422X, ER422DX ER422DDX, 722X, 722DDX ER431, ER431D, ER431DD ER431TX ER432X, ER432DX, ER432DDX ER432TX 732X, 732DX, 732TNX .451 (11.46) .451 (11.46) .546 (13.87) .556 (14.12) .388 (9.86) .393 (9.99) .398 (10.11) .493 (12.52) .503 (12.78) Notes: 1. Spreader pad material: Diallyl Phthalate. 2. To specify an "M", "M2" or "M3" spreader pad, refer to the mounting variants portion of the part number example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise specied, tolerance is .010" (0.25). 5/. Add 25 m to the contact resistance shown in the datasheet. 6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. 7/. Add 50 m to the contact resistance shown in the datasheet. 8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet. 9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.) (800) 284-7007 * www.teledynerelays.com +44 (0) 1236 453124 * www.teledyne-europe.com (c) 2008 Teledyne Relays Appendix A: Ground Pin Positions O.200 [O5.08] 363 "Z" POSITION "X" POSITION "Y" POSITION "Z" O.200 [O5.08] "Y" 453 TO-5 Relays: ER411T, ER412, ER412T, ER420, ER421, ER422, ER431T, ER432, ER432T, 712, 712TN, 400H, 400K, 400V, RF300, RF303, RF341, RF312, RF310, RF313, RF320, RF323 "Y" POSITION POSITION TO-5 Relays: ER411, ER431, RF311, RF331 POSITION .100 [2.54] "W" "Z" .100 [2.54] .050 [1.27] "X" .100 [2.54] POSITION POSITION "Z" POSITION POSITION .100 [2.54] POSITION "U" POSITION (ER116C and ER136C only) Centigrid(R) Relays: RF180, ER116C, 122C, ER136C .100 [2.54] Centigrid(R) Relays: RF100, RF103, ER114, ER134, 172 Indicates ground pin position Indicates glass insulated lead position Indicates ground pin or lead position depending on relay type (c) 2008 Teledyne Relays "Y" .100 [2.54] NOTES 1. Terminal views shown 2. Dimensions are in inches (mm) 3. Tolerances: .010 (.25) unless otherwise specied 4. Ground pin positions are within .015 (0.38) dia. of true position 5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref. 6. Lead dia. 0.017 (0.43) nom. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE