ACDC
Specification
20 Watts
•Low Cost
•Small Size
•Universal Input
•Single Outputs from 3.3 V to 24 V
•Peak Load Capability
•Low Profile
•Nonstandard Outputs Available
CU20 Series
Input
Input Voltage • 85-264 VAC (120-370 VDC)
Input Frequency • 47-63 Hz
Input Current • 0.25 A rms at 230 VAC
Inrush Current • 20 A at 115 VAC, 40 A at 230 VAC,
cold start +25 şC
Earth Leakage Current • <1.5 mA
Input Protection • 2 A fuse
Output
Output Voltage • See table
Output Voltage Trim • ±5%
Initial Set Accuracy • ±1%
Minimum Load • No minimum load required
Start Up Delay • 1.5 s max
Start Up Rise Time • 14 ms max
Hold Up Time • 16 ms typical at full load & 115 VAC
Drift • ±0.6%
Line Regulation • ±0.5% max
Load Regulation • ±1.0% max
Transient Response • 4% max deviation, recovery to within
1% in 500 µs for 25% load change
Ripple & Noise • 1% max pk-pk (see note 1)
Overvoltage Protection • 130-150% of Vnom, recycle input to reset
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature • 0.05%/˚C
Coefficient
xppower.com
General
Efficiency • Measured with 230 VAC & 100% load
(See table)
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • 67 kHz typical
Power Density • 3.91 W/In3
MTBF • >500 kHrs per MIL-HDBK-217F
(15 & 24 V units >400 kHrs)
Environmental
Operating Temperature • 0 ˚C to +65 ˚C, derate from 100% load at
+45 ˚C to 0% at +65 ˚C
Cooling • Convection-cooled
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -20 ˚C to +85 ˚C
Operating Altitude • 3000 m
Vibration • 10 Hz to 500 Hz, 2 g for 10 mins/cycle
60 min each cycle
EMC & Safety
Emissions • FCC20780 Level B,
EN55022 Class B conducted
ESD Immunity • EN61000-4-2, level 3, Perf Criteria A
Radiated Immunity • EN61000-4-3, level 3, Perf Criteria A
EFT/Burst • EN61000-4-4, level 2, Perf Criteria A
Surge • EN61000-4-5, level 3, Perf Criteria A
Conducted Immunity • EN61000-4-6, 10 V, Perf Criteria A
Dips & interruptions • EN61000-4-11, 30% 10 ms,
60% 1000 ms, 100% 5000 ms,
Perf Criteria A, B, B
Safety Approvals • EN60950-1, UL60950-1,
CSA22.2 No. 60950-1, CE Mark LVD