2
B3WB3W
■Ratings/Characteristics
■Operating Characteristics
6 × 6 mm Models
12 × 12 mm Models
■Model Structure
Rating (resistive load) 1 to 50 mA, 3 to 24 VDC
Minimum applicable load (reference value) 10 μA at 1 VDC (resistive load)
Ambient operating temperature -25°C to +70°C at 60%RH max. (with no icing or condensation)
Ambient operating humidity 35% to 85% (at +5 to +35°C)
Contact form SPST-NO
Contact resistance (initial value) 100 mΩ max.
Insulation resistance 100 MΩ min. (at 250 VDC with insulation tester)
Dielectric strength 500 VAC, 50/60 Hz for 1 min
Bounce time 5 ms max.
Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance Destruction: 1,000 m/s2 {approx. 100 G} max.
Malfunction: 100 m/s2 {approx. 10 G} max.
Durability B3W-1000:
1.57 N (standard force):1,000,000 operations min.
2.26 N (high-force):300,000 operations min.
B3W-4000:
1.96 N (standard force):3,000,000 operations min.
3.43 N (high-force):1,000,000 operations min.
Weight 6 × 6 mm: approx. 0.3 g, 12 × 12 mm: approx. 1 g
Degree of protection IEC IP67
Washing Possible
Type B3W-1000 series
Operating force (OF) 1.57 N 2.26 N
Item Model B3W-1@@0B3W-1@@2
Operating force (OF) 1.57 N {160 gf} max. 2.26 N {230 gf} max.
Releasing force (RF) 0.2 N {20 gf} min. 0.49 N {50 gf} min.
Pretravel (PT) 0.25+0.2/–0.1 mm
Type B3W-4000 series
Operating force (OF) 1.96 N 3.43 N
Item Model B3W-4@@0B3W-4@@5
Operating force (OF) 1.96 N {200 gf} max. 3.43 N {350 gf} max.
Releasing force (RF) 0.29 N {30 gf} min. 0.49 N {50 gf} min.
Pretravel (PT) 0.3+0.2/–0.1 mm
Plunger
Cover Spacer
Contact dome
Sealed rubber
Fixed contact
Base