Specifications
DescriptionFeature
18 to 30V dc (10% max. ripple)
Supply Voltage and
Current Indicators: @ 100 mA max. current at 18V dc; 70 mA max. current at 30V dc
Audible Alarm: @ 25 mA max. current at 18 to 30V dc
LEDs or audible alarm are independently selected: Green, Red, Yellow; 1-3 colors
depending on model
Indicators
Indicator ON/OFF: 10 ms (max.)Input Response Time
2.7 KHz ± 500 Hz
Oscillation Frequency
( Audible only ) Max. Intensity (typical): 95 db @ 1 meter
The audible intensity can be adjusted by unscrewing the cover.The cover should not
be unscrewed more than one and a half turns or it may detach during operation. For
max. intensity, remove the center plug by rotating it 180° counterclockwise.
Audible Adjustments
Bases and Covers: ABS
Construction
Light Segment: Polycarbonate
General-Purpose: IEC IP67
Environmental Rating
Audible: IEC IP50
Integral 4-pin or 5-pin Euro-style QD, 150 mm PVC pigtail with QD, or 2 m (6.5’) integral
cable, depending on model
Connections
General-Purpose: −40° to +50° C (−40° to +122° F)
Operating Conditions
Audible: −20° to +50° C (−4° to +122° F)
Certifications
3Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
P/N 145315 rev. C
145315